Cone-beam computed tomography of mandibular foramen and lingula for mandibular anesthesia

被引:27
作者
Ahn, Byeong-Seob [1 ]
Oh, Song Hee [1 ]
Heo, Chong-Kwan [2 ]
Kim, Gyu-Tae [1 ]
Choi, Yong-Suk [1 ]
Hwang, Eui-Hwan [1 ]
机构
[1] Kyung Hee Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, 26 Kyungheedaero Dongdaemun Gu, Seoul 02447, South Korea
[2] Kyung Hee Univ, Sch Dent, Seoul, South Korea
关键词
Mandible; Anatomy; Cross-Sectional; Nerve Block; Cone-Beam Computed Tomography; SHAPE; CT; LOCALIZATION; OSTEOTOMY; DOSIMETRY; DEVICES; RAMUS;
D O I
10.5624/isd.2020.50.2.125
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose : The positions of the mandibular foramen (MnF) and the lingula affect the success rate of inferior alveolar nerve block. The objective of this study was to investigate aspects of the MnF and the lingula relevant for mandibular block anesthesia using cone -beam computed tomography (CBCT). Materials and Methods : Fifty CBCT scans were collected from a picture archiving and communications system. All scans were taken using an Alphard Vega 3030 (Asahi Roentgen Co. Ltd., Kyoto, Japan). Fifty-eight MnFs of 30 subjects were included in the study. The position of the MnF, the size of the MnF, the position of the lingula, the size of the lingula, and the shape of the lingula were measured and recorded. All data were statistically analyzed at a significance level of P < 0.05. Results : The position of MnF was 0.1 mm and 0.8 mm below the occlusal plane in males and females, respectively. The horizontal position of the MnF was slightly anterior to the center of the ramus in males and in the center in females (P < 0.05). The vertical position of the MnF was lower in females than in males (P < 0.05). The MnF was an oval shape with a longer anteroposterior dimension. The height of the lingula was 9.3 mm in males and 8.2 mm in females. The nodular type was the most common shape of the lingula, followed by the triangular, truncated, and assimilated types. Conclusion : CBCT provided useful information about the MnF and lingula. This information could improve the success rate of mandibular blocks. (Imaging Sci Dent 2020; 50: 125-32)
引用
收藏
页码:125 / 132
页数:8
相关论文
共 16 条
[1]   Radiographic localization of mandibular anesthesia landmarks [J].
Afsar, A ;
Haas, DA ;
Rossouw, PE ;
Wood, RE .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1998, 86 (02) :234-241
[2]  
Ezoddini Ardakani Fatemeh, 2010, J Dent Res Dent Clin Dent Prospects, V4, P47
[3]  
Haas Daniel A, 2011, J Am Dent Assoc, V142 Suppl 3, p8S
[4]   Shape, Height, and Location of the Lingula for Sagittal Ramus Osteotomy in Thais [J].
Jansisyanont, P. ;
Apinhasmit, W. ;
Chompoopong, S. .
CLINICAL ANATOMY, 2009, 22 (07) :787-793
[5]   Trigeminal nerve anatomy: Illustrated using examples of abnormalities [J].
Kamel, HAM ;
Toland, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (01) :247-251
[6]  
Keetley A, 2001, Prim Dent Care, V8, P139, DOI 10.1308/135576101322462174
[7]   Shape of the lingula and its localization by panoramic radiograph versus dry mandibular measurement [J].
Kositbowornchai, Suwadee ;
Siritapetawee, Mookhda ;
Damrongrungruang, Teerasak ;
Khongkankong, Waranyoo ;
Cbatrchaiwiwatana, Supaporn ;
Khamanarong, Kimaporn ;
Chanthaooplee, Tanarat .
SURGICAL AND RADIOLOGIC ANATOMY, 2007, 29 (08) :689-694
[8]  
Loubele M, 2007, INT J ORAL MAX IMPL, V22, P446
[9]   Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit [J].
Ludlow, JB ;
Davies-Ludlow, LE ;
Brooks, SL .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (04) :229-234
[10]   Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology [J].
Ludlow, John B. ;
Ivanovic, Marija .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 106 (01) :106-114