Wavelet-based event detection in implantable cardiac rhythm management devices

被引:12
作者
Åström, M
Olmos, S
Sörnmo, L
机构
[1] Lund Univ, Dept Elect Engn, SE-22100 Lund, Sweden
[2] Univ Zaragoza, Dept Elect Engn & Commun, Zaragoza 50009, Spain
关键词
electrogram; event detection; implantable cardiac devices; pacemakers; wavelets;
D O I
10.1109/TBME.2005.869775
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a novel event detector for implantable devices. The algorithm is based on a signal model which describes an event as a linear combination of basis functions. The linear combination involves two fundamental electrogram waveforms represented at different time scales. An efficient, low-complexity detector is developed using the dyadic wavelet transform with integer filter coefficients, and a generalized likelihood ratio test. The results show that reliable detection is obtained at an intermediate signal-to-noise ratio (SNR = 25 dB) for various common noise sources. In terms of probabilities of missed events and false alarms, an over-all performance of 0.7% and 0.1%, respectively, was achieved on electrograms corrupted by the different noise types at an intermediate SNR.
引用
收藏
页码:478 / 484
页数:7
相关论文
共 20 条
[1]  
[Anonymous], 1997, A Wavelet Tour of Signal Processing
[2]  
[Anonymous], 1998, FUNDEMENTALS STAT SI
[3]  
ASTROM M, 2003, THESIS LUND U LUND
[4]   In vitro and in vivo evaluation of electromagnetic interference between wireless home monitoring pacemakers and GSM mobile phones [J].
Barbaro, V ;
Bartolini, P ;
Calcagnini, G ;
Censi, F ;
Floris, M ;
Pignalberi, C ;
Ricci, R ;
Santini, M .
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 :3602-3605
[5]   A HYBRID ANALOG AND DIGITAL VLSI NEURAL-NETWORK FOR INTRACARDIAC MORPHOLOGY CLASSIFICATION [J].
COGGINS, R ;
JABRI, M ;
FLOWER, B ;
PICKARD, S .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1995, 30 (05) :542-550
[6]   ELECTRONIC ARTICLE SURVEILLANCE - A POSSIBLE DANGER FOR PACEMAKER PATIENTS [J].
DODINOT, B ;
GODENIR, JP ;
COSTA, AB ;
ZELLER, C ;
BROSCHART, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (01) :46-53
[7]   CARDIAC PACING AND PACEMAKERS .3. SENSING CARDIAC ELECTROGRAM [J].
FURMAN, S ;
HURZELER, P ;
DECAPRIO, V .
AMERICAN HEART JOURNAL, 1977, 93 (06) :794-801
[8]   Interference with cardiac pacemakers by cellular telephones [J].
Hayes, DL ;
Wang, PJ ;
Reynolds, DW ;
Estes, NAM ;
Griffith, JL ;
Steffens, RA ;
Carlo, GL ;
Findlay, GK ;
Johnson, CM .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (21) :1473-1479
[9]   INTERFERENCE IN PACEMAKERS [J].
IRNICH, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (06) :1021-1048
[10]   MUSCLE NOISE AND INTERFERENCE BEHAVIOR IN PACEMAKERS - A COMPARATIVE-STUDY [J].
IRNICH, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (01) :125-132