Rapid Determination of Non-Steroidal Anti-Inflammatory Drugs in Urine Samples after In-Matrix Derivatization and Fabric Phase Sorptive Extraction-Gas Chromatography-Mass Spectrometry Analysis

被引:22
作者
Jain, Bharti [1 ]
Jain, Rajeev [2 ]
Kabir, Abuzar [3 ]
Sharma, Shweta [1 ]
机构
[1] Panjab Univ, Inst Forens Sci & Criminol, Chandigarh 160014, India
[2] Forens Toxicol Div, Cent Forens Sci Lab, Plot 2,Sect 36-A,Dakshin Marg, Chandigarh 160036, India
[3] Florida Int Univ, Dept Chem & Biochem, Miami, FL 33199 USA
来源
MOLECULES | 2022年 / 27卷 / 21期
关键词
fabric phase sorptive extraction; gas chromatography-mass spectrometry; non-steroidal anti-inflammatory drugs; derivatization; urine analysis; LIQUID-LIQUID MICROEXTRACTION; MOLECULARLY IMPRINTED POLYMER; PORT SILYLATION; HUMAN PLASMA; NAPROXEN; CHLOROFORMATE; DICLOFENAC; ADSORBENT; ESTROGENS; BLOOD;
D O I
10.3390/molecules27217188
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Fabric phase sorptive extraction (FPSE) has become a popular sorptive-based microextraction technique for the rapid analysis of a wide variety of analytes in complex matrices. The present study describes a simple and green analytical protocol based on in-matrix methyl chloroformate (MCF) derivatization of non-steroidal anti-inflammatory (NSAID) drugs in urine samples followed by FPSE and gas chromatography-mass spectrometry (GC-MS) analysis. Use of MCF as derivatizing reagent saves substantial amounts of time, reagent and energy, and can be directly performed in aqueous samples without any sample pre-treatment. The derivatized analytes were extracted using sol-gel Carbowax 20M coated FPSE membrane and eluted in 0.5 mL of MeOH for GC-MS analysis. A chemometric design of experiment-based approach was utilized comprising a Placket-Burman design (PBD) and central composite design (CCD) for screening and optimization of significant variables of derivatization and FPSE protocol, respectively. Under optimized conditions, the proposed FPSE-GC-MS method exhibited good linearity in the range of 0.1-10 mu g mL(-1) with coefficients of determination (R-2) in the range of 0.998-0.999. The intra-day and inter-day precisions for the proposed method were lower than <7% and <10%, respectively. The developed method has been successfully applied to the determination of NSAIDs in urine samples of patients under their medication. Finally, the green character of the proposed method was evaluated using ComplexGAPI tool. The proposed method will pave the way for simper analysis of polar drugs by FPSE-GC-MS.
引用
收藏
页数:17
相关论文
共 42 条
  • [1] Mixed-mode fabric phase sorptive extraction of multiple tetracycline residues from milk samples prior to high performance liquid chromatography-ultraviolet analysis
    Agadellis, Efstratios
    Tartaglia, Angela
    Locatelli, Marcello
    Kabir, Abuzar
    Furton, Kenneth G.
    Samanidou, Victoria
    [J]. MICROCHEMICAL JOURNAL, 2020, 159
  • [2] Magnet integrated fabric phase sorptive extraction of selected endocrine disrupting chemicals from human urine followed by high-performance liquid chromatography - photodiode array analysis
    Alampanos, Vasileios
    Kabir, Abuzar
    Furton, Kenneth
    Samanidou, Victoria
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2021, 1654
  • [3] Fabric phase sorptive extraction combined with high-performance-liquid chromatography-photodiode array analysis for the determination of seven parabens in human breast tissues: Application to cancerous and non-cancerous samples
    Alampanos, Vasileios
    Kabir, Abuzar
    Furton, Kenneth G.
    Roje, Zeljka
    Vrcek, Ivana Vinkovic
    Samanidou, Victoria
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2020, 1630
  • [4] Determination of Non-Steroidal Anti-Inflammatory Drugs in Animal Urine Samples by Ultrasound Vortex-Assisted Dispersive Liquid-Liquid Microextraction and Gas Chromatography Coupled to Ion Trap-Mass Spectrometry
    Avino, Pasquale
    Notardonato, Ivan
    Passarella, Sergio
    Russo, Mario Vincenzo
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (16):
  • [5] Ayazi Z, 2015, ANAL METHODS-UK, V7, P3200, DOI [10.1039/C4AY02734E, 10.1039/c4ay02734e]
  • [6] Gas-chromatography mass spectrometry determination of pharmacologically active substances in urine and blood samples by use of a continuous solid-phase extraction system and microwave-assisted derivatization
    Azzouz, Abdelmonaim
    Ballesteros, Evaristo
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 891 : 12 - 19
  • [7] Tandem air-agitated liquid-liquid microextraction as an efficient method for determination of acidic drugs in complicated matrices
    Bazregar, Mohammad
    Rajabi, Maryam
    Yamini, Yadollah
    Asghari, Alireza
    Hemmati, Maryam
    [J]. ANALYTICA CHIMICA ACTA, 2016, 917 : 44 - 52
  • [8] A new molecularly imprinted polymer for the selective extraction of naproxen from urine samples by solid-phase extraction
    Caro, E
    Marcé, RM
    Cormack, PAG
    Sherrington, DC
    Borrull, F
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 137 - 143
  • [9] Strengthening adsorption characteristics of non-steroidal anti-inflammatory drug onto microwave-assisted mesoporous material: Process design, mechanism and characterization
    Dwivedi, Amarendra Dhar
    Gopal, Krishna
    Jain, Rajeev
    [J]. CHEMICAL ENGINEERING JOURNAL, 2011, 168 (03) : 1279 - 1288
  • [10] Renewable sorbent dispersive solid phase extraction automated by Lab-In-Syringe using magnetite-functionalized hydrophilic-lipophilic balanced sorbent coupled online to HPLC for determination of surface water contaminants
    Gemuh, Celestine Vubangsi
    Machacek, Miloslav
    Solich, Petr
    Horstkotte, Burkhard
    [J]. ANALYTICA CHIMICA ACTA, 2022, 1210