The analysis of factors influencing the Frequency Response of the transformer winding

被引:0
作者
Banaszak, Szymon [1 ]
机构
[1] Zachodniopomorski Uniwersytet Technol Szczecinie, Katedra Elektrotechnol & Diagnostyki, PL-70313 Szczecin, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2012年 / 88卷 / 11A期
关键词
transformer; active part; Frequency Response Analysis - FRA; deformation;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper describes results of two experiments based on frequency response measurements performed on HV transformer winding. The first of them was based on the controlled deformations of windings, while during the second one additional capacitance elements were attached to various points of the winding. These results were to be found similar to results taken from deformations, therefore it can be concluded that described axial, but also radial deformations depend mainly on capacitance changes (The analysis of factors influencing the Frequency Response of the transformer winding).
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Optical Frequency-Response Analysis for Power Transformer
    Ma, Guoming
    Liu, Yunpeng
    Li, Yabo
    Fan, Xiaozhouce
    Xu, Ce
    Qin, Weiqi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (03) : 1562 - 1570
  • [32] A New Multi-Conductor Transmission Line Model of Transformer Winding for Frequency Response Analysis Considering the Frequency-Dependent Property of the Lamination Core
    Wang, Song
    Guo, Ze
    Zhu, Ting
    Feng, Hanke
    Wang, Shuhong
    ENERGIES, 2018, 11 (04)
  • [33] Diagnosis and Analysis of the Transformer Winding Deformation Fault
    Li Xinyu
    Wang Qinghao
    Liu Peng
    Pang Yanjun
    Li Simin
    Li Yan
    Zhang Ning
    Wang Enlu
    Lin Bin
    Yue Yangzhuo
    Liu Chenyang
    Liu Qiang
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 2018 - 2022
  • [34] Based on Short-time Fourier Transform Impulse Frequency Response Analysis in the Application of the Transformer Winding Deformation
    Li, Yaning
    Peng, Wenbang
    Zhu, Xiaoyan
    Wei, Genyuan
    Yu, Hong
    Qian, Guochao
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 371 - 375
  • [35] Frequency Response Analysis vs. Flux Division Measurement in Detection of Transformer Winding Internal Short Circuit
    Bagheri, Mehdi
    Naderi, Mohammad Salay
    Blackburn, Trevor
    Phung, B. T.
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2012,
  • [36] Derivation of transformer winding equivalent circuit by employing the transfer function obtained from frequency response analysis data
    Zhang, Zhi
    IET ELECTRIC POWER APPLICATIONS, 2024, 18 (07) : 826 - 840
  • [37] Double-End Excitation of a Single Isolated Transformer Winding: An Improved Frequency Response Analysis for Fault Detection
    Pramanik, Saurav
    Ganesh, Aravind
    Duvvury, V. S. B. Chaitanya
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (01) : 619 - 626
  • [38] Diagnosis Method of Transformer Winding Deformation Faults based on Frequency Response Binary Image
    Zhao Z.
    Tang C.
    Li C.
    Zhou Q.
    Xia Q.
    Yao C.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (05): : 1526 - 1534
  • [39] Understanding Online Frequency Response Signatures for Transformer Winding Deformation: Axial Displacement Simulation
    Zhao, Zhongyong
    Islam, Syed
    Hashemnia, Naser
    Hu, Di
    Yao, Chenguo
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 404 - 407
  • [40] Survey of Frequency Response Analysis on Winding Deformation of Transformers
    Li, Zhenhua
    Zhang, Yangpo
    Zhu, Binxin
    Luo, Yufei
    Zhang, Tao
    Zhang, Zhi
    2019 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG 2019), 2019, : 567 - 571