The analysis of factors influencing the Frequency Response of the transformer winding

被引:0
作者
Banaszak, Szymon [1 ]
机构
[1] Zachodniopomorski Uniwersytet Technol Szczecinie, Katedra Elektrotechnol & Diagnostyki, PL-70313 Szczecin, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2012年 / 88卷 / 11A期
关键词
transformer; active part; Frequency Response Analysis - FRA; deformation;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper describes results of two experiments based on frequency response measurements performed on HV transformer winding. The first of them was based on the controlled deformations of windings, while during the second one additional capacitance elements were attached to various points of the winding. These results were to be found similar to results taken from deformations, therefore it can be concluded that described axial, but also radial deformations depend mainly on capacitance changes (The analysis of factors influencing the Frequency Response of the transformer winding).
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Application of Statistical Interpretation Technique for Frequency Response Analysis and Detection of Axial Displacement in Transformer Winding
    Sardar, Suman
    Kumar, Amrendra
    Chatterjee, Biswendu
    Dalai, Sovan
    2017 IEEE CALCUTTA CONFERENCE (CALCON), 2017, : 461 - 464
  • [22] Inductive Coupling Method for On-line Frequency Response Analysis (FRA) for Transformer Winding Diagnostic
    Rathnayaka, Sooriya Bandara
    See, Kye Yak
    Prajapati, Manish
    Li, Kangrong
    Narampanawe, Nishshanka Bandara
    Fan, Fei
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 88 - 92
  • [23] Proposal of Objective Criterion in Diagnosis of Abnormalities of Power-Transformer Winding by Frequency Response Analysis
    Miyazaki, S.
    Mizutani, Y.
    Taguchi, A.
    Murakami, J.
    Tsuji, N.
    Takashima, M.
    Kato, O.
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 74 - 77
  • [24] The influence of interwinding short-circuits on frequency response of transformer winding
    Banaszak, Szymon
    Gawrylczyk, Konstanty Marek
    Klistala, Tomasz
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11B): : 138 - 141
  • [25] Time frequency analysis method for the detection of winding deformation in transformer
    Santhi, S.
    Jayashankar, V
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 1620 - +
  • [26] Time Frequency Analysis Method for the Detection of Winding Deformation in Transformer
    Santhi, S.
    Jayashankar, V
    Jagadeesh, Kumar, V
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 2126 - +
  • [27] Investigation of the Effect of Winding Clamping Structure on Frequency Response Signature of 11 kV Distribution Transformer
    Murthy, Avinash Srikanta
    Azis, Norhafiz
    Al-Ameri, Salem
    Yousof, Mohd Fairouz Mohd
    Jasni, Jasronita
    Talib, Mohd Aizam
    ENERGIES, 2018, 11 (09)
  • [28] Transformer Winding Condition Assessment Using Feedforward Artificial Neural Network and Frequency Response Measurements
    Tahir, Mehran
    Tenbohlen, Stefan
    ENERGIES, 2021, 14 (11)
  • [29] High frequency model of transformer winding
    Shibuya, Y
    Fujita, S
    ELECTRICAL ENGINEERING IN JAPAN, 2004, 146 (03) : 8 - 16
  • [30] A Novel Approach to Assess Power Transformer Winding Conditions Using Regression Analysis and Frequency Response Measurements
    Thango, Bonginkosi A.
    Nnachi, Agha F.
    Dlamini, Goodness A.
    Bokoro, Pitshou N.
    ENERGIES, 2022, 15 (07)