The analysis of factors influencing the Frequency Response of the transformer winding

被引:0
作者
Banaszak, Szymon [1 ]
机构
[1] Zachodniopomorski Uniwersytet Technol Szczecinie, Katedra Elektrotechnol & Diagnostyki, PL-70313 Szczecin, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2012年 / 88卷 / 11A期
关键词
transformer; active part; Frequency Response Analysis - FRA; deformation;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper describes results of two experiments based on frequency response measurements performed on HV transformer winding. The first of them was based on the controlled deformations of windings, while during the second one additional capacitance elements were attached to various points of the winding. These results were to be found similar to results taken from deformations, therefore it can be concluded that described axial, but also radial deformations depend mainly on capacitance changes (The analysis of factors influencing the Frequency Response of the transformer winding).
引用
收藏
页数:3
相关论文
共 50 条
  • [2] Power Transformer Winding Deformity of the Factors Influencing Analysis
    Wang Min
    Jiang Yan-lei
    Cui Feng
    Wang Xue-li
    12TH ANNUAL MEETING OF CHINA ASSOCIATION FOR SCIENCE AND TECHNOLOGY ON INFORMATION AND COMMUNICATION TECHNOLOGY AND SMART GRID, 2010, : 61 - +
  • [3] On-site diagnosis of transformer winding by frequency Response Analysis
    Miyazaki S.
    Mizutani Y.
    Matsumoto K.
    Nakamura S.
    IEEJ Transactions on Power and Energy, 2010, 130 (04) : 451 - 459+8
  • [4] Influence of Temperature on Frequency Response Analysis of Transformer Winding
    Bagheri, Mehdi
    Phung, B. T.
    Blackburn, Trevor
    Naderian, Ali
    2013 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2013, : 40 - 44
  • [5] Bushing Characteristic Impacts on On-line Frequency Response Analysis of Transformer Winding
    Bagheri, Mehdi
    Naderi, Mohammad Salay
    Blackburn, Trevor
    Phung, B. T.
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2012, : 956 - 961
  • [6] Modeling of frequency response of transformer winding with axial deformations
    Gawrylczyk, K. M.
    Banaszak, S.
    ARCHIVES OF ELECTRICAL ENGINEERING, 2014, 63 (01) : 5 - 17
  • [7] Fault Diagnostic in the Transformer Winding by Sweep Frequency Response Analysis
    Kumar, Abhishek
    Aggarwal, Priyanshi
    Kumbhar, Ganesh B.
    Bhalja, Bhavesh R.
    4TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON 2019), 2019,
  • [8] Case Studies of Factors Influencing Frequency Response Analysis Measurements and Power Transformer Diagnostics
    Reykherdt, Andrey A.
    Davydov, Valery
    IEEE ELECTRICAL INSULATION MAGAZINE, 2011, 27 (01) : 22 - 30
  • [9] Abnormality Diagnosis of Transformer Winding by Frequency Response Analysis (FRA) Using Circuit Model
    Miyazaki, Satoru
    Mizutani, Yoshinobu
    Okamoto, Tatsuki
    Wada, Yoshihiro
    Hayashida, Chikara
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 273 - 276
  • [10] Influence of Temperature and Moisture Content on Frequency Response Analysis of Transformer Winding
    Bagheri, Mehdi
    Phung, B. T.
    Blackburn, Trevor
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (03) : 1393 - 1404