Intrinsic increase in lymphangion muscle contractility in response to elevated afterload

被引:101
作者
Davis, Michael J. [1 ]
Scallan, Joshua P. [1 ]
Wolpers, John H. [1 ]
Muthuchamy, Mariappan [2 ]
Gashev, Anatoliy A. [2 ]
Zawieja, David C. [2 ]
机构
[1] Univ Missouri, Sch Med, Dept Med Pharmacol & Physiol, Columbia, MO 65212 USA
[2] Texas A&M Hlth Sci Ctr, Dept Syst Biol & Translat Med, Temple, TX USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2012年 / 303卷 / 07期
关键词
pressure-volume relationship; positive inotropy; isolated vessel; lymphatic pump; homeometric regulation; stroke work; Anrep effect; PRESSURE-VOLUME RELATIONSHIPS; RAT MESENTERIC LYMPHATICS; OUTFLOW PRESSURE; VENTRICULAR CONTRACTILITY; TRANSMURAL PRESSURE; CAPILLARY-PRESSURE; VESSELS; FLOW; PUMP; LYMPHEDEMA;
D O I
10.1152/ajpheart.01097.2011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Davis MJ, Scallan JP, Wolpers JH, Muthuchamy M, Gashev AA, Zawieja DC. Intrinsic increase in lymphangion muscle contractility in response to elevated afterload. Am J Physiol Heart Circ Physiol 303: H795-H808, 2012. First published August 10, 2012; doi:10.1152/ajpheart.01097.2011.-Collectinglymphatic vessels share functional and biochemical characteristics with cardiac muscle; thus, we hypothesized that the lymphatic vessel pump would exhibit behavior analogous to homeometric regulation of the cardiac pump in its adaptation to elevated afterload, i.e., an increase in contractility. Single lymphangions containing two valves were isolated from the rat mesenteric microcirculation, cannulated, and pressurized for in vitro study. Pressures at either end of the lymphangion [input pressure (P-in), preload; output pressure (P-out), afterload] were set by a servo controller. Intralymphangion pressure (P-L) was measured using a servo-null micropipette while internal diameter and valve positions were monitored using video methods. The responses to step- and ramp-wise increases in P-out (at low, constant P-in) were determined. P-L and diameter data recorded during single contraction cycles were used to generate pressure-volume (P-V) relationships for the subsequent analysis of lymphangion pump behavior. Ramp-wise P-out elevation led to progressive vessel constriction, a rise in end-systolic diameter, and an increase in contraction frequency. Step-wise P-out elevation produced initial vessel distention followed by time-dependent declines in end-systolic and end-diastolic diameters. Significantly, a 30% leftward shift in the end-systolic P-V relationship accompanied an 84% increase in dP/dt after a step increase in P-out, consistent with an increase in contractility. Calculations of stroke work from the P-V loop area revealed that robust pumps produced net positive work to expel fluid throughout the entire afterload range, whereas weaker pumps exhibited progressively more negative work as gradual afterload elevation led to pump failure. We conclude that lymphatic muscle adapts to output pressure elevation with an intrinsic increase in contractility and that this compensatory mechanism facilitates the maintenance of lymph pump output in the face of edemagenic and/or gravitational loads.
引用
收藏
页码:H795 / H808
页数:14
相关论文
共 57 条
[1]   THE EFFECTS OF MUSCLE LENGTH ON INTRACELLULAR CALCIUM TRANSIENTS IN MAMMALIAN CARDIAC-MUSCLE [J].
ALLEN, DG ;
KURIHARA, S .
JOURNAL OF PHYSIOLOGY-LONDON, 1982, 327 (JUN) :79-94
[2]  
AUKLAND K, 1994, NEWS PHYSIOL SCI, V9, P214
[3]   VENTRICULAR PRESSURE VOLUME RELATIONS INVIVO [J].
BAAN, J ;
VANDERVELDE, ET ;
STEENDIJK, P .
EUROPEAN HEART JOURNAL, 1992, 13 :2-6
[4]   CHARACTERIZATION OF INTACT MESENTERIC LYMPHATIC PUMP AND ITS RESPONSIVENESS TO ACUTE EDEMAGENIC STRESS [J].
BENOIT, JN ;
ZAWIEJA, DC ;
GOODMAN, AH ;
GRANGER, HJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (06) :H2059-H2069
[5]  
Bridenbaugh Eric A, 2003, Lymphat Res Biol, V1, P147, DOI 10.1089/153968503321642633
[6]   Co-ordination of contractile activity in guinea-pig mesenteric lymphatics [J].
Crowe, MJ ;
vonderWeid, PY ;
Brock, JA ;
VanHelden, DF .
JOURNAL OF PHYSIOLOGY-LONDON, 1997, 500 (01) :235-244
[7]   Modulation of lymphatic muscle contractility by the neuropeptide substance P [J].
Davis, Michael J. ;
Lane, Megan M. ;
Davis, Ann M. ;
Durtschi, David ;
Zawieja, David C. ;
Muthuchamy, Mariappan ;
Gashev, Anatoliy A. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2008, 295 (02) :H587-H597
[8]   Determinants of valve gating in collecting lymphatic vessels from rat mesentery [J].
Davis, Michael J. ;
Rahbar, Elaheh ;
Gashev, Anatoliy A. ;
Zawieja, David C. ;
Moore, James E., Jr. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2011, 301 (01) :H48-H60
[9]   Myogenic constriction and dilation of isolated lymphatic vessels [J].
Davis, Michael J. ;
Davis, Ann M. ;
Ku, Christine W. ;
Gashev, Anatoliy A. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2009, 296 (02) :H293-H302
[10]   An improved, computer-based method to automatically track internal and external diameter of isolated microvessels [J].
Davis, MJ .
MICROCIRCULATION, 2005, 12 (04) :361-372