Patient dose in digital projection radiography

被引:12
作者
Compagnone, Gaetano [1 ]
Pagan, Laura [1 ]
Baleni, Massimo Casadio [2 ]
Calzolaio, Felice Luca [2 ]
Barozzi, Libero [2 ]
Bergamini, Carlo [1 ]
机构
[1] St Orsola Marcello Malpighi Hosp, Dept Med Phys, I-40138 Bologna, Italy
[2] St Orsola Marcello Malpighi Hosp, Radiol Emergency Dept, I-40138 Bologna, Italy
关键词
D O I
10.1093/rpd/ncn013
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and directradiography (DR): a difference between them can be stated in terms of dose and image quality. In the Radiology Emergency Department of our hospital, a flat-panel DR equipment (Siemens Axiom Aristos FX) and two CR systems (Kodak CR-850) are employed. In 2006, five standard radiographic examinations (abdomen, chest, lumbar spine, pelvis, skull) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) and effective dose (E) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD and E in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.
引用
收藏
页码:135 / 137
页数:3
相关论文
共 8 条
[1]  
[Anonymous], 2005, J ICRU
[2]   Comparison of radiation doses to patients undergoing standard radiographic examinations with conventional screen-film radiography, computed radiography and direct digital radiography [J].
Compagnone, G. ;
Baleni, M. Casad ;
Pagan, L. ;
Calzolaio, F. L. ;
Barozzi, L. ;
Bergamini, C. .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (947) :899-904
[3]   Local diagnostic reference levels in standard X-ray examinations [J].
Compagnone, G ;
Pagan, L ;
Bergamini, C .
RADIATION PROTECTION DOSIMETRY, 2005, 113 (01) :54-63
[4]   Comparison of six phantoms for entrance skin dose evaluation in 11 standard X-ray examinations [J].
Compagnone, Gaetano ;
Pagan, Laura ;
Bergamini, Carlo .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (01) :101-113
[5]  
European Commission, 1996, EUROPEAN GUIDELINES
[6]   BASIC IMAGING PROPERTIES OF A COMPUTED RADIOGRAPHIC SYSTEM WITH PHOTOSTIMULABLE PHOSPHORS [J].
FUJITA, H ;
UEDA, K ;
MORISHITA, J ;
FUJIKAWA, T ;
OHTSUKA, A ;
SAI, T .
MEDICAL PHYSICS, 1989, 16 (01) :52-59
[7]   Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications [J].
Granfors, PR ;
Aufrichtig, R .
MEDICAL PHYSICS, 2000, 27 (06) :1324-1331
[8]  
HART D, 1994, NRPBR262