Axillary and tympanic membrane temperature measurements are unreliable early after cardiopulmonary bypass

被引:8
作者
Khan, TA
Vohra, HA
Paul, S
Rosin, MD
Patel, RL
机构
[1] Univ Hosp Coventry & Warwickshire NHS Trust, Dept Cardiothorac Surg, Walsgrave Hosp, Coventry CV2 2DX, W Midlands, England
[2] Univ Oxford, Diabet Trial Unit, Oxford, England
关键词
body temperature; axillary; tympanic; bladder; cardiopulmonary bypass; catheterization; swan ganz; anaesthesia recovery period; critical care;
D O I
10.1017/S0265021505001936
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective: Inaccurate measurements of body temperature following cardiopulmonary bypass may be associated with serious complications. The purpose of this study was to determine whether axillary and tympanic temperature measurements correlate with the urinary bladder temperature in the early postcardiac surgery period. Methods: Forty-nine adult patients who underwent cardiac surgery under cardiopulmonary bypass at our institution were prospectively studied. Urinary bladder, right axillary, right tympanic and left tympanic temperature measurements were simultaneously recorded at 0, 6, 12 and 18 h following cardiopulmonary bypass. Patients had one to four sets of recordings and a total of 629 temperature measurements were recorded. The mean difference (bias) between the bladder and each of the other methods and limits of agreement were calculated using Bland and Altman method. Results: The mean core body temperature recorded from the bladder on admission to the intensive care unit was 36.4 degrees C. After 6, 12 and 18 h the mean core body temperature was 37.4 degrees C (range: 35.2-39.0), 37.5 degrees C and 37.45 degrees C, respectively. The mean differences (bias) between the bladder temperature and the other three methods were: left tympanic, 0.65 degrees C (95% CI: -0.24 to 1.58); right tympanic, 0.57 degrees C (95% CI: -0.48 to 1.63) and right axillary, 0.55 degrees C (95% CI: -0.27 to 1.36). Conclusions: The axilla and tympanic membrane are unreliable sites for core body temperature measurement early after cardiopulmonary bypass in adult patients and clinical decisions should be based on more reliable methods.
引用
收藏
页码:551 / 554
页数:4
相关论文
共 14 条
  • [1] Accuracy of an infrared tympanic thermometer
    Amoateng-Adjepong, Y
    Del Mundo, J
    Manthous, CA
    [J]. CHEST, 1999, 115 (04) : 1002 - 1005
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] BOJAR RM, 1999, MANUAL PERIOPERATIVE, P124
  • [4] Tympanic membrane temperature as a measure of core temperature
    Childs, C
    Harrison, R
    Hodkinson, C
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1999, 80 (03) : 262 - 266
  • [5] Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core, tympanic, and oral methods
    Giuliano, KK
    Scott, SS
    Elliot, S
    Giuliano, AJ
    [J]. CRITICAL CARE MEDICINE, 1999, 27 (10) : 2188 - 2193
  • [6] Postoperative hyperthermia is associated with cognitive dysfunction after coronary artery bypass graft surgery
    Grocott, HP
    Mackensen, GB
    Grigore, AM
    Mathew, J
    Reves, JG
    Phillips-Bute, B
    Smith, PK
    Newman, MF
    [J]. STROKE, 2002, 33 (02) : 537 - 541
  • [7] Association between postoperative hypothermia and adverse outcome after coronary artery bypass surgery
    Insler, SR
    O'Connor, MS
    Leventhal, MJ
    Nelson, DR
    Starr, NJ
    [J]. ANNALS OF THORACIC SURGERY, 2000, 70 (01) : 175 - 181
  • [8] Temperature measurement in intensive care patients:: comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method
    Lefrant, JY
    Muller, L
    Coussaye, JE
    Benbabaali, M
    Lebris, C
    Zeitoun, N
    Mari, C
    Saïssi, G
    Ripart, J
    Eledjam, JJ
    [J]. INTENSIVE CARE MEDICINE, 2003, 29 (03) : 414 - 418
  • [9] Estimating core temperature in infants and children after cardiac surgery: a comparison of six methods
    Maxton, FJC
    Justin, L
    Gillies, D
    [J]. JOURNAL OF ADVANCED NURSING, 2004, 45 (02) : 214 - 222
  • [10] CORE TEMPERATURE-MEASUREMENT IN THE INTENSIVE-CARE UNIT
    NIERMAN, DM
    [J]. CRITICAL CARE MEDICINE, 1991, 19 (06) : 818 - 823