Comparison of Glucose Fluctuations between Day- and Night-Time Measured Using a Continuous Glucose Monitoring System in Diabetic Dogs

被引:13
作者
Mori, Akihiro [1 ]
Kurishima, Miyuki [1 ]
Oda, Hitomi [1 ]
Saeki, Kaori [1 ]
Arai, Toshiro [2 ]
Sako, Toshinori [1 ]
机构
[1] Nippon Vet & Life Sci Univ, Dept Vet Nursing & Technol, Sch Vet Sci, Musashino, Tokyo 1808602, Japan
[2] Nippon Vet & Life Sci Univ, Dept Vet Med, Sch Vet Sci, Musashino, Tokyo 1808602, Japan
关键词
continuous glucose monitoring system; diabetes mellitus; insulin; SERUM GLYCATED ALBUMIN; TIME-ACTION PROFILES; GLYCEMIC CONTROL; GROWTH-HORMONE; INSULIN; HYPOGLYCEMIA; NEUROPATHY; MELLITUS; CHILDREN; ANIMALS;
D O I
10.1292/jvms.12-0123
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Monitoring of blood glucose concentration is important to evaluate the diabetic status of dogs. Continuous glucose monitoring systems (CGMS) have been applied in veterinary medicine for glucose monitoring in diabetic dogs. The purpose of the study was to evaluate the daily glycemic profiles obtained with CGMS and compare glucose fluctuations between day- and night-time in diabetic dogs. Five diabetic dogs were used in this study and were treated with either NPH insulin or insulin detemir. For data analyses, day-time was defined as 9:00 am-9:00 pm and night-time as 9:00 pm-9:00 am. Using glucose profiles, we determined the mean glucose concentrations (1-and 12-hr intervals), and times spent in hyperglycemia >200 mg/dl or hypoglycemia <60 mg/dl. None of the parameters differed significantly between day-time and night-time in dogs treated with NPH insulin or insulin detemir. In conclusion, this study confirmed, using CGMS, that there are no differences in glucose fluctuations between day-and night-time, in diabetic dogs on a similar feeding regimen and insulin administration.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 22 条
[1]   Hypoglycemia prevalence in prepubertal children with type 1 diabetes on standard insulin regimen: Use of continuous glucose monitoring system [J].
Amin, R ;
Ross, K ;
Acerini, CL ;
Edge, JA ;
Warner, J ;
Dunger, DB .
DIABETES CARE, 2003, 26 (03) :662-667
[2]   Update on drugs used to treat endocrine diseases in small animals [J].
Behrend, Ellen N. .
VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2006, 36 (05) :1087-+
[3]   INSULIN PHARMACOKINETICS [J].
BINDER, C ;
LAURITZEN, T ;
FABER, O ;
PRAMMING, S .
DIABETES CARE, 1984, 7 (02) :188-199
[4]   Evaluation of a continuous glucose monitoring system in diabetic dogs [J].
Davison, LJ ;
Slater, LA ;
Herrtage, ME ;
Church, DB ;
Judge, S ;
Ristic, JME ;
Catchpole, B .
JOURNAL OF SMALL ANIMAL PRACTICE, 2003, 44 (10) :435-442
[5]  
DCCT Res Grp, 1991, AM J MED, V90, P450, DOI 10.1016/0002-9343(91)80085-Z
[6]   Use of continuous blood glucose monitoring for animals with diabetes mellitus [J].
DeClue, Amy E. ;
Cohn, Leah A. ;
Kerl, Marie E. ;
Wiedmeyer, Charles E. .
JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2004, 40 (03) :171-173
[7]  
Feldman E.C. Nelson R.W., 2004, Canine and feline endocrinology and reproduction
[8]   Eight-point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in type 1 diabetes [J].
Fiallo-Scharer, R ;
Xing, DY ;
Weinzimer, S ;
Buckingham, B ;
Mauras, N ;
Tansey, M ;
Chase, P ;
Beck, R ;
Ruedy, K ;
Kollman, C ;
Tamborlane, W ;
Chase, HP ;
Fiallo-Scharer, R ;
Fisher, JH ;
Tallant, B ;
Tsalikian, E ;
Tansey, MJ ;
Larson, LF ;
Coffey, J ;
Wysocki, T ;
Mauras, N ;
Fox, LA ;
Bird, K ;
Lofton, KL ;
Buckingham, BA ;
Wilson, DM ;
Block, JM ;
Clinton, P ;
Weinzimer, SA ;
Tamborlane, WV ;
Doyle, EA ;
Sikes, K ;
Beck, RW ;
Ruedy, KJ ;
Kollman, C ;
Xing, DY ;
Kalajian, A ;
Silvester, CR ;
Steffes, MW ;
Bucksa, JM ;
Nowicki, ML ;
Van Hale, CA ;
Grave, GD ;
Linder, B ;
Winer, KK ;
Becker, DM ;
Cox, C ;
Ryan, CM ;
White, NH ;
White, PC .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (06) :3387-3391
[9]  
Gobello C, 2002, CAN J VET RES, V66, P108
[10]  
JOHNSON CA, 1983, J AM VET MED ASSOC, V183, P1007