Circle- and Grid-Wise Analyses of Peripapillary Nerve Fiber Layers by Spectral Domain Optical Coherence Tomography in Early-Stage Glaucoma

被引:5
作者
Mayama, Chihiro [1 ]
Saito, Hitomi [1 ]
Hirasawa, Hiroyo [1 ]
Konno, Shinsuke [1 ]
Tomidokoro, Atsuo [1 ]
Araie, Makoto [1 ,2 ]
Iwase, Aiko [3 ]
Ohkubo, Shinji [4 ]
Sugiyama, Kazuhisa [4 ]
Otani, Tomohiro [5 ]
Kishi, Shoji [6 ]
Matsushita, Kenji [6 ]
Maeda, Naoyuki [6 ]
Hangai, Masanori [7 ]
Yoshimura, Nagahisa [7 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Ophthalmol, Tokyo 1138655, Japan
[2] Kanto Cent Hosp, Tokyo, Japan
[3] Tajimi Iwase Eye Clin, Tajimi, Japan
[4] Kanazawa Univ, Grad Sch Med Sci, Dept Ophthalmol & Visual Sci, Kanazawa, Ishikawa, Japan
[5] Gunma Univ, Sch Med, Dept Ophthalmol, Maebashi, Gunma 371, Japan
[6] Osaka Univ, Grad Sch Med, Dept Ophthalmol, Osaka, Japan
[7] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Kyoto, Japan
关键词
glaucoma; optic coherence tomography; retinal nerve fiber layer; SCANNING LASER POLARIMETRY; TIME-DOMAIN; FOURIER-DOMAIN; STRATUS OCT; CIRRUS HD; GDX VCC; DIAGNOSTIC-PERFORMANCE; DISEASE SEVERITY; THICKNESS; REPRODUCIBILITY;
D O I
10.1167/iovs.13-11603
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To study diagnostic performances of circle-and grid-wise analyses of peripapillary retinal nerve fiber layer thickness (RNFLT) using spectral domain optical coherence tomography (SD-OCT) in early-stage glaucoma. METHODS. Eighty-nine open-angle glaucoma (OAG) eyes (mean deviation: 2.5 +/- 1.8 dB) and 89 age-matched normal eyes were studied. Peripapillary RNFLT was analyzed using an SD-OCT raster scan in a 6.0 x 6.0-mm area. Averaged RNFLT was calculated over 0.1 x 0.1-, 0.21 x 0.21-, or 0.42 x 0.42-mm grids in the peripapillary area (grid method), or arcuate sector areas between 2.8- and 4.0-mm diameter circles (annulus method), or along a 3.4-mm diameter circle (circle method). Normative data-based cutoff values for averaged RNFLT and number of abnormal grid locations (grid method) or sectors (annulus or circle method) were varied. RESULTS. The grid method showed the best power of sensitivity/specificity of 0.94/0.96 with any five contiguous 0.21 x 0.21-mm grid locations with a 2.5 percentile cutoff, followed by the annulus method of 0.81/0.98, and the circle method of 0.76/0.97, with 308 sectors. The sensitivity of the grid method was significantly higher than that of the other methods (P < 0.001), whereas the specificity was not. Coefficients of variation and interclass correlation coefficients of intervisit measurements of averaged RNFLT over each 0.21 x 0.21-mm grid were 3.1% to 11.3% and 0.937 to 0.760, respectively, in a separate OAG patient group. CONCLUSIONS. Grid-wise analyses of peripapillary RNFLT for differentiating early-stage glaucoma showed >0.90 sensitivity and >= 0.95 specificity.
引用
收藏
页码:4519 / 4526
页数:8
相关论文
共 56 条
  • [51] Comparison of Different Spectral Domain Optical Coherence Tomography Scanning Areas for Glaucoma Diagnosis
    Rao, Harsha L.
    Zangwill, Linda M.
    Weinreb, Robert N.
    Sample, Pamela A.
    Alencar, Luciana M.
    Medeiros, Felipe A.
    [J]. OPHTHALMOLOGY, 2010, 117 (09) : 1692 - U55
  • [52] Diagnostic ability of retinal ganglion cell complex, retinal nerve fiber layer, and optic nerve head measurements by Fourier-domain optical coherence tomography
    Schulze, Andreas
    Lamparter, Julia
    Pfeiffer, Norbert
    Berisha, Fatmire
    Schmidtmann, Irene
    Hoffmann, Esther M.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (07) : 1039 - 1045
  • [53] Scanning laser polarimetry with enhanced corneal compensation and optical coherence tomography in normal and glaucomatous eyes
    Sehi, Mitra
    Ume, Stephen
    Greenfield, David S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (05) : 2099 - 2104
  • [54] Diagnostic Ability of Fourier-Domain vs Time-Domain Optical Coherence Tomography for Glaucoma Detection
    Sehi, Mitra
    Grewal, Dilraj S.
    Sheets, Clinton W.
    Greenfield, David S.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (04) : 597 - 605
  • [55] Comparison of Retinal Nerve Fiber Layer Thickness Measured by Cirrus HD and Stratus Optical Coherence Tomography
    Sung, Kyung Rim
    Kim, Dong Yoon
    Park, Sung Bae
    Kook, Michael S.
    [J]. OPHTHALMOLOGY, 2009, 116 (07) : 1264 - 1270
  • [56] Comparison of Optical Coherence Tomography and Scanning Laser Polarimetry for Detection of Localized Retinal Nerve Fiber Layer Defects
    Yoo, Young Cheol
    Park, Ki Ho
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (04) : 229 - 236