COMPARING DIGITAL TOMOSYNTHESIS TO CONE-BEAM CT FOR POSITION VERIFICATION IN PATIENTS UNDERGOING PARTIAL BREAST IRRADIATION

被引:32
作者
Zhang, Junan [1 ]
Wu, Jackie [1 ]
Godfrey, Devon J. [1 ]
Fatunase, Toyosi [1 ]
Marks, Lawrence B. [1 ]
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2009年 / 73卷 / 03期
关键词
On-board imaging; Digital tomosynthesis; Cone-beam CT; Patient localization; Breast cancer; Limited angle cone-beam CT; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; 2ND CANCERS; LOCALIZATION; FEASIBILITY; LUMPECTOMY; GUIDANCE; WOMEN; SETUP;
D O I
10.1016/j.ijrobp.2008.10.036
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate digital tomosynthesis (DTS) technology for daily positioning of patients receiving accelerated partial breast irradiation (APBI) and to compare the positioning accuracy of DTS to three-dimensional cone-beam computed tomography (CBCT). Methods and Materials: Ten patients who underwent APBI were scanned daily with on-board CBCT. A subset of the CBCT projections was used to reconstruct a stack of DTS image slices. To optimize soft-tissue visibility, the DTS images were reconstructed in oblique directions so that the tumor bed, breast tissue, ribs, and lungs were well separated. Coronal and sagittal DTS images were also reconstructed. Translational shifts of DTS images were obtained on different days from the same patients and were compared with the translational shifts of corresponding CBCT images. Seventy-seven CBCT scans and 291 DTS scans were obtained from nine evaluable patients. Results: Tumor beds were best visible in the oblique DTS scans. One-dimensional positioning differences between DTS and CBCT images were 0.8-1.7 mm for the six patients with clips present and 1.2-2.0 mm for the three patients without clips. Because of the limited DTS scan angle, the DTS registration accuracy along the off-plane direction is lower than the accuracy along the in-plane directions. Conclusions: For patients receiving APBI, DTS localization offers comparable accuracy to CBCT localization for daily patient positioning while reducing mechanical constraints and imaging dose. Published by Elsevier Inc.
引用
收藏
页码:952 / 957
页数:6
相关论文
共 21 条
  • [1] Digital x-ray tomosynthesis: current state of the art and clinical potential
    Dobbins, JT
    Godfrey, DJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) : R65 - R106
  • [2] Assessment of the residual error in soft tissue setup in patients undergoing partial breast irradiation: Results of a prospective study using cone-beam computed tomography
    Fatunase, Toyosi
    Wang, Zhiheng
    Yoo, Sua
    Hubbs, Jessica L.
    Prosnitz, Robert G.
    Yin, Fang-Fang
    Marks, Lawrence B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1025 - 1034
  • [3] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [4] Second cancers after conservative surgery and radiation for Stages I-II breast cancer: Identifying a subset of women at increased risk
    Fowble, B
    Hanlon, A
    Freedman, G
    Nicolaou, N
    Anderson, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (03): : 679 - 690
  • [5] Digital tomosynthesis with an on-board kilovoltage imaging device
    Godfrey, DJ
    Yin, FF
    Oldham, M
    Yoo, S
    Willett, C
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (01): : 8 - 15
  • [6] Optimization of the matrix inversion tomosynthesis (MITS) impulse response and modulation transfer function characteristics for chest imaging
    Godfrey, DJ
    McAdams, HP
    Dobbins, JT
    [J]. MEDICAL PHYSICS, 2006, 33 (03) : 655 - 667
  • [8] Tomosynthesis: Potential clinical role in breast Imaging
    Gur, David
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (03) : 614 - 615
  • [9] Intensity-modulated radiation therapy, protons, and the risk of second cancers
    Hall, Eric J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (01): : 1 - 7
  • [10] Digital Tomosynthesis in breast imaging
    Niklason, LT
    Christian, BT
    Niklason, LE
    Kopans, DB
    Castleberry, DE
    OpsahlOng, BH
    Landberg, CE
    Slanetz, PJ
    Giardino, AA
    Moore, R
    Albagli, D
    DeJule, MC
    Fitzgerald, PF
    Fobare, DF
    Giambattista, BW
    Kwasnick, RF
    Liu, JQ
    Lubowski, SJ
    Possin, GE
    Richotte, JF
    Wei, CY
    Wirth, RF
    [J]. RADIOLOGY, 1997, 205 (02) : 399 - 406