Eccentricity dependent changes of density, spacing and packing arrangement of parafoveal cones

被引:63
|
作者
Lombardo, Marco [1 ]
Serrao, Sebastiano [1 ]
Ducoli, Pietro [1 ]
Lombardo, Giuseppe [2 ,3 ]
机构
[1] Fdn GB Bietti IRCCS, Rome, Italy
[2] Univ Calabria, CNR IPCF Unit Support Cosenza, I-87036 Arcavacata Di Rende, Italy
[3] Vis Engn, Rome, Italy
关键词
adaptive optics; cone density; cone spacing; cone packing arrangement; ADAPTIVE-OPTICS; MEASUREMENT ERROR; RETINAL IMAGES; PHOTORECEPTOR; EYE; RESOLUTION; LIMIT; OPHTHALMOSCOPE; IDENTIFICATION; DEGENERATION;
D O I
10.1111/opo.12053
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To investigate the distribution of cone density and spacing as well as the preferred packing arrangement of the cone mosaic as a function of retinal eccentricity. Methods An adaptive optics retinal camera (rtx1, www.imagine-eyes.com) was used to obtain images of the parafoveal cone mosaic in nineteen healthy volunteers. Cone density and spacing were estimated for each subject (both eyes) using a sampling window of 80x80 pixels, at 250-, 450-, 650- and 1100-m eccentricities from the fovea along the nasal and temporal retina of both eyes. The inter-subject and intra-subject variation of cone density and spacing were calculated via Coefficient of Variation (CoV). Cone packing arrangement was assessed using Voronoi analysis; calculations were done over 1024x128 pixels image sections of the cone mosaic across the horizontal meridian from 200- to 1050-m eccentricities. Results The inter-subject variation of parafoveal cone density ranged between 10% and 15% (p<0.001) and the intra-subject variation of cone density was lower than 8% in all subjects, except for two. The cone spacing values showed a moderate inter-subject (CoV<7%; p<0.001) and a low intra-subject variation (CoV<4% in all subjects, except for two cases). In the parafoveal region, 40-50% of cones were hexagonally arranged; the percentage of non-hexagonal Voronoi tiles increased at greater eccentricities. Conclusion The use of multiple and complementary metric descriptors allows for a more detailed description of packing distribution and preferred arrangement of cone photoreceptors across the parafoveal retina.
引用
收藏
页码:516 / 526
页数:11
相关论文
共 5 条
  • [1] Influence of sampling window size and orientation on parafoveal cone packing density
    Lombardo, Marco
    Serrao, Sebastiano
    Ducoli, Pietro
    Lombardo, Giuseppe
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (08): : 1318 - 1331
  • [2] Repeatability of In Vivo Parafoveal Cone Density and Spacing Measurements
    Garrioch, Robert
    Langlo, Christopher
    Dubis, Adam M.
    Cooper, Robert F.
    Dubra, Alfredo
    Carroll, Joseph
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (05) : 632 - 643
  • [3] Variation of Cone Photoreceptor Packing Density with Retinal Eccentricity and Age
    Song, Hongxin
    Chui, Toco Yuen Ping
    Zhong, Zhangyi
    Elsner, Ann E.
    Burns, Stephen A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7376 - 7384
  • [4] Variations in the cone packing density with eccentricity in emmetropes
    Dabir, S.
    Mangalesh, S.
    Kumar, K. A.
    Kummelil, M. K.
    Roy, A. Sinha
    Shetty, R.
    EYE, 2014, 28 (12) : 1488 - 1493
  • [5] Distribution of cone density, spacing and arrangement in adult healthy retinas with adaptive optics flood illumination
    Legras, Richard
    Gaudric, Alain
    Woog, Kelly
    PLOS ONE, 2018, 13 (01):