Tibial cyst formation after anterior cruciate ligament reconstruction using a new bioabsorbable screw

被引:34
作者
Malhan, K [1 ]
Kumar, A [1 ]
Rees, D [1 ]
机构
[1] Robert Jones & Agnes Hunt Orthopaed Hosp, Oswestry SY10 7AG, Shrops, England
关键词
tibial cyst; bioabsorbable screw; anterior cruciate ligament reconstruction;
D O I
10.1016/S0968-0160(01)00109-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We report a case of tibial cyst formation twelve months after anterior cruciate ligament reconstruction using hamstring graft. A composite bioabsorbable interference screw made of 'beta tricalcium phosphate and Poly L-lactide' fixed the graft distally. The patient presented with acute symptoms of pain and swelling over the proximal tibia. Curettage of the cyst resulted in complete recovery within 3 months. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:73 / 75
页数:3
相关论文
共 11 条
[1]   PRELIMINARY-RESULTS OF AN ABSORBABLE INTERFERENCE SCREW [J].
BARBER, FA ;
ELROD, BF ;
MCGUIRE, DA ;
PAULOS, LE .
ARTHROSCOPY, 1995, 11 (05) :537-548
[2]   A new bioabsorbable interference screw: Preliminary results of a prospective, multicenter, randomized clinical trial [J].
Benedetto, KP ;
Fellinger, M ;
Lim, TE ;
Passler, JM ;
Schoen, JL ;
Willems, WJ .
ARTHROSCOPY, 2000, 16 (01) :41-48
[3]   OSTEOLYTIC CHANGES ACCOMPANYING DEGRADATION OF ABSORBABLE FRACTURE FIXATION IMPLANTS [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :679-682
[4]   Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: A prospective computed tomography-controlled study [J].
Fink, C ;
Benedetto, KP ;
Hackl, W ;
Hoser, C ;
Freund, MC ;
Rieger, M .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2000, 16 (05) :491-498
[5]   Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation [J].
Martinek, V ;
Friederich, NF .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1999, 15 (03) :317-320
[6]   Pretibial cyst formation after anterior cruciate ligament surgery with soft tissue autografts [J].
Simonian, PT ;
Wickiewicz, TL ;
O'Brien, SJ ;
Dines, JS ;
Schatz, JA ;
Warren, RF .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1998, 14 (02) :215-220
[7]   Clinical degradation and biocompatibility of different bioabsorbable interference screws: A report of six cases [J].
Stahelin, AC ;
Weiler, A ;
Rufenacht, H ;
Hoffmann, R ;
Geissmann, A ;
Feinstein, R .
ARTHROSCOPY, 1997, 13 (02) :238-244
[8]   Foreign body gonitis caused by a broken poly-L-lactic acid screw [J].
Takizawa, T ;
Akizuki, S ;
Horiuchi, H ;
Yasukawa, Y .
ARTHROSCOPY, 1998, 14 (03) :329-330
[9]   SUBCUTANEOUS PRETIBIAL CYST FORMATION ASSOCIATED WITH ANTERIOR CRUCIATE LIGAMENT ALLOGRAFTS - A REPORT OF 4 CASES AND LITERATURE-REVIEW [J].
VICTOROFF, BN ;
PAULOS, L ;
BECK, C ;
GOODFELLOW, DB .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1995, 11 (04) :486-494
[10]   Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction [J].
Warden, WH ;
Friedman, R ;
Teresi, LM ;
Jackson, DW .
ARTHROSCOPY, 1999, 15 (05) :474-480