Gated Myocardial Perfusion SPECT: Algorithm-Specific Influence of Reorientation on Calculation of Left Ventricular Volumes and Ejection Fraction

被引:9
|
作者
Knollmann, Daniela [1 ]
Winz, Oliver H. [1 ]
Meyer, Philipp T. [1 ]
Raptis, Mardjan [1 ]
Krohn, Thomas [1 ]
Koch, Karl-Christian [2 ]
Schaefer, Wolfgang M. [1 ]
机构
[1] Rhein Westfal TH Aachen, Univ Hosp Aachen, Dept Nucl Med, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Univ Hosp Aachen, Med Clin Cardiol 1, D-52074 Aachen, Germany
关键词
gated SPECT; QGS; 4D-MSPECT; CARE heart; reorientation;
D O I
10.2967/jnumed.108.050484
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gated myocardial perfusion SPECT allows calculation of end-diastolic and end-systolic volumes (EDV and ESV, respectively) and left ventricular ejection fraction (LVEF). The quantification algorithms QGS (quantitative gated SPECT), 4D-MSPECT, and CARE heart show a good correlation with cardiac MRI. Nevertheless, differences in contour finding suggest algorithm-specific effects if heart axes vary. The effect of tilting heart axes on gated SPECT was quantified as a possible source of error. Methods: Sixty men underwent gated SPECT (450 MBq of Tc-99m-tetrofosmin or sestamibi, 8 gates/cycle). After correct reorientation (R-0), datasets were tilted by 5, 10, 15, 20, 30, and 45 along both long axes (R-5, R-10, R-15, R-20, R-30, and R-45, respectively). EDV, ESV, and LVEF were calculated using QGS, 4D-MSPECT, and CARE heart. Because a 15 tilt could be a maximum possible misreorientation in routine, R-0 and R-15 results were analyzed in detail. Absolute-difference values between results of tilted and correctly reoriented datasets were calculated for all tilts and algorithms. Results: QGS and CARE heart succeeded for R-0 and R-15 in all cases, whereas 4D-MSPECT failed to find the basal plane in 1 case (patient B). R-2 values between paired R-15/R-0 results were 0.992 (QGS), 0.796 (4D-MSPECT; R-2 = 0.919 inn = 59 after exclusion of the failed case), and 0.916 (CARE heart) for EDV; 0.994 (QGS), 0.852 (4D-MSPECT; R-2 = 0.906 in n = 59), and 0.899 (CARE heart) for ESV; and 0.988 (QGS), 0.814 (4D-MSPECT; R-2 = 0.810 in n = 59), and 0.746 (CARE heart) for LVEF Concerning all levels of misreorientation, 1 patient was excluded for all algorithms because of multiple problems in contour finding; additionally for 4D-MSPECT patient B was excluded. In the 45 group, QGS succeeded in 58 of 59 cases, 4D-MSPECT in 58 of 58, and CARE heart in 33 of 59. Mean absolute differences for EDV ranged from 5.1 +/- 4.1 to 12.8 +/- 10.5 mL for QGS, from 6.7 +/- 6.3 to 34.2 +/- 20.7 mL for 4D-MSPECT, and from 5.4 +/- 5.6 to 25.2 +/- 16.1 mL for CARE heart (tilts between 5 and 45). Mean absolute differences for ESV ranged from 4.1 +/- 3.7 to 8.0 +/- 9.4 mL for QGS, from 5.6 +/- 8.0 to 10.0 +/- 10.5 mL for 4D-MSPECT, and from 5.4 +/- 5.6 to 25.5 +/- 16.1 mLfor CARE heart. Mean absolute differences for LVEF ranged from 1.1% +/- 1.0% to 2.2% +/- 1.8% for QGS, from 4.0% +/- 3.5% +/- to 8.0% +/- 7.1 for 4D-MSPECT, and from 3.4% +/- 2.9% to 9.2% +/- 6.0% for CARE heart. Conclusion: Despite tilted heart axes, QGS showed stable results even when using tilts up to 45. 4D-MSPECT and CARE heart results varied with reorientation of the heart axis, implying that published validation results apply to correctly reoriented data only.
引用
收藏
页码:1636 / 1642
页数:7
相关论文
共 50 条
  • [21] Quantification of left ventricular volumes and ejection fraction from 16- and rebinned 8-frame gated 99mTc-tetrofosmin SPECT
    Schaefer, W. M.
    Kaiser, H-J.
    Kuehl, H.
    Koch, K-C.
    Nowak, B.
    Buell, U.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2007, 46 (01): : 22 - 28
  • [22] Potential Impact of SPECT Resolution on Quantification of Left Ventricular Volumes and Ejection Fraction: A Phantom Study
    Liu, Hui
    Aslan, Mehmet
    Sandoval, Veronica
    Liu, Yi-Hwa
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2022, 42 (05) : 734 - 743
  • [23] Assessment of poststress left ventricular ejection fraction by gated SPECT: comparison with equilibrium radionuclide angiocardiography
    Wanda Acampa
    Maria Grazia Caprio
    Emanuele Nicolai
    Raffaele Liuzzi
    Serena De Luca
    Enza Capasso
    Luca Luongo
    Mario Petretta
    Alberto Cuocolo
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 349 - 356
  • [24] Gated myocardial perfusion tomography for the assessment of left ventricular function and volumes: Comparison with echocardiography
    Cwajg, E
    Cwajg, J
    He, ZX
    Hwang, WS
    Keng, F
    Nagueh, SF
    Verani, MS
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (11) : 1857 - 1865
  • [25] Assessment of poststress left ventricular ejection fraction by gated SPECT: comparison with equilibrium radionuclide angiocardiography
    Acampa, Wanda
    Caprio, Maria Grazia
    Nicolai, Emanuele
    Liuzzi, Raffaele
    De Luca, Serena
    Capasso, Enza
    Luongo, Luca
    Petretta, Mario
    Cuocolo, Alberto
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (02) : 349 - 356
  • [26] Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies
    Giulia Montelatici
    Roberto Sciagrà
    Alessandro Passeri
    Manjola Dona
    Alberto Pupi
    European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 : 2059 - 2065
  • [27] Myocardial perfusion and left ventricular quantitative parameters obtained using gated myocardial SPECT: Comparison of three software packages
    Sotiria Alexiou
    Panagiotis Georgoulias
    George Angelidis
    Varvara Valotassiou
    Ioannis Tsougos
    Dimitrios Psimadas
    Velissarios Lakiotis
    Agaristi Kaspiri
    Dimitrios Alexopoulos
    Dimitrios Apostolopoulos
    Pavlos Vassilakos
    Journal of Nuclear Cardiology, 2018, 25 : 911 - 924
  • [28] Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies
    Montelatici, Giulia
    Sciagra, Roberto
    Passeri, Alessandro
    Dona, Manjola
    Pupi, Alberto
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (11) : 2059 - 2065
  • [29] Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard
    Soneson, Helen
    Hedeer, Fredrik
    Arevalo, Carmen
    Carlsson, Marcus
    Engblom, Henrik
    Ubachs, Joey F. A.
    Arheden, Hakan
    Heiberg, Einar
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (05) : 874 - 885
  • [30] Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard
    Helen Soneson
    Fredrik Hedeer
    Carmen Arévalo
    Marcus Carlsson
    Henrik Engblom
    Joey F. A. Ubachs
    Håkan Arheden
    Einar Heiberg
    Journal of Nuclear Cardiology, 2011, 18 : 874 - 885