Prestresses in bilayered all-ceramic restorations

被引:65
作者
Aboushelib, Moustafa N. [1 ,2 ,3 ]
Feilzer, Albert J. [2 ,3 ]
de Jager, Niek [2 ,3 ]
Kleverlaan, Cornelis J. [2 ,3 ]
机构
[1] Univ Alexandria, Fac Dent, Dent Biomat Dept, Alexandria, Egypt
[2] Vrije Univ, Acad Ctr Dent Amsterdam ACTA, Dept Dent Mat Sci, Amsterdam, Netherlands
[3] Univ Amsterdam, Amsterdam, Netherlands
关键词
ceramic; zirconia; finite element analysis; fractography;
D O I
10.1002/jbm.b.31083
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: A general trend in all ceramic systems is to use veneering ceramics of slightly lower thermal expansion coefficients compared with that of the framework resulting in a positive mismatch in thermal expansion coefficient (+Delta TEC). The concept behind this TEC mismatch is to generate compressive stresses in the weaker veneering ceramic and thus enhance the overall strength of the restoration. This technique had excellent results with porcelain fused to metal restorations (PFM). However, there are concerns to apply this concept to all-ceramic restorations. The aim of this research was to determine the stresses in bilayered all-ceramic restorations due to the mismatch in TEC. Materials and methods: Two commercial veneering ceramics with a TEC lower than that of zirconia (+Delta TEC); NobelRondo zirconia (TM) and Lava Ceram (TM), plus one experimental veneering ceramic with an identical TEC that matches that of zirconia (Delta TEC = 0) were used to veneer zirconia discs. The specimens were loaded in biaxial flexure test setup with the veneer ceramic in tension. The stresses due to load application and TEC mismatch were calculated using fractography, engineering mathematics, and finite element analysis (FEA). Results: In this study, the highest load at failure (64 N) was obtained with the experimental veneer where the thermal mismatch between zirconia and veneering ceramic was minimal. For the two Commercial veneer ceramics the magnitude of the thermal mismatch localized at the zirconia veneer interface (42 MPa) exceeded the bond strength between the two materials and resulted in delamination failure during testing (ca. 50 MPa). Significance: For all-ceramic zirconia veneered restorations it is recommended to minimize the thermal mismatch as much as possible. (c) 2008 Wiley Periodicals, Inc.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 22 条
[1]   Microtensile bond strength of different components of core veneered all-ceramic restorations [J].
Aboushelib, MN ;
de Jager, N ;
Kleverlaan, CJ ;
Feiler, AJ .
DENTAL MATERIALS, 2005, 21 (10) :984-991
[2]   Microtensile bond strength of different components of core veneered all-ceramic restorations - Part II: Zirconia veneering ceramics [J].
Aboushelib, Moustafa N. ;
Kleverlaan, Cornelis J. ;
Feilzer, Albert J. .
DENTAL MATERIALS, 2006, 22 (09) :857-863
[3]   TRANSIENT AND RESIDUAL-STRESS IN A PORCELAIN-METAL STRIP [J].
ASAOKA, K ;
TESK, JA .
JOURNAL OF DENTAL RESEARCH, 1990, 69 (02) :463-469
[4]   The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns [J].
De Jager, N ;
Pallav, P ;
Feilzer, AJ .
DENTAL MATERIALS, 2005, 21 (03) :242-251
[5]  
DeHoff PH, 1998, J BIOMED MATER RES, V41, P614, DOI 10.1002/(SICI)1097-4636(19980915)41:4<614::AID-JBM14>3.0.CO
[6]  
2-E
[7]   The in-vitro clinical failure of all-ceramic crowns and the connector area of fixed partial dentures: the influence of interfacial surface roughness [J].
Fleming, GJP ;
Nolan, L ;
Harris, JJ .
JOURNAL OF DENTISTRY, 2005, 33 (05) :405-412
[8]  
FLEMING GJP, 2006, DENT MATER, V22, P1
[9]  
Guazzato M, 2004, INT J PROSTHODONT, V17, P142
[10]   Stress distributions in thin bilayer discs subjected to ball-on-ring tests [J].
Hsueh, CH ;
Lance, MJ ;
Ferber, MK .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2005, 88 (06) :1687-1690