Corneal shape changes induced by first and second generation silicone hydrogel contact lenses in daily wear

被引:37
作者
Alba-Bueno, Francisco [1 ]
Beltran-Masgoret, Angel [1 ]
Sanjuan, Cristian [1 ]
Biarnes, Marc [1 ]
Marin, Jesus [1 ]
机构
[1] EUOOT, Terrassa 08222, Barcelona, Spain
关键词
Silicone hydrogel contact lenses; Corneal shape change; Computerized corneal topography; Oxygen transmissibility; Modulus of elasticity;
D O I
10.1016/j.clae.2008.11.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the corneal topographical changes induced by two first and second generation silicone-hydrogel (SiH) contact lenses after 3 months of daily wear (DW). Methods: Prospective, consecutive case-series in which patients wore one of 3 different contact lenses (either the first generation SiH Focus Night & Day, the second generation SiH Acuvue Oasys or the monthly disposable Soflens 38 hydrogel lens as control group) on a DW basis for 3 months. Over-refraction, visual acuity, mean keratometry, corneal astigmatism, corneal eccentricity, superficial regularity and superficial asymmetry indices were monitored over the 3-month period. Results: Nineteen eyes of 10 patients completed the study. Seven Focus Night & Day, 7 Acuvue Oasys and 5 Soflens 38 contact lenses were fitted. There were no significant changes between any of the parameters measured at the 3-month visit in any of the SiH groups (non-parametric Wilcoxon test, p > 0.05). However, the control group (Soflens 38) showed statistically significant changes regarding mean keratometry, corneal astigmatism and corneal eccentricity (p < 0.05). Three patients wearing the first generation SiH showed adverse events of different degree related to their high modulus of elasticity. Conclusions: After 3 months of DW, wearers of first and second generation SiH lenses showed greater corneal stability than hydrogel monthly disposable contact lenses users regarding commonly used topographic corneal shape indices. However, complications related to the mechanical properties of first generation SiH were seen in three patients in the follow-up time. (C) 2009 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:88 / 92
页数:5
相关论文
共 18 条
[11]  
Lopez Alemany A, 2003, USO PROLONGADO LENTE
[12]  
Morgan PB, 2005, IS DAILY WEAR PRINCI
[13]  
Sweeney Deborah F, 2003, Eye Contact Lens, V29, pS22
[14]   Mucin balls with wear of conventional and silicone hydrogel contact lenses [J].
Tan, J ;
Keay, L ;
Jalbert, I ;
Naduvilath, TJ ;
Sweeney, DF ;
Holden, BA .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (04) :291-297
[15]   Predicting time to refractive stability after discontinuation of rigid contact lens wear before refractive surgery [J].
Tsai, PS ;
Dowidar, A ;
Naseri, A ;
McLeod, SD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (11) :2290-2294
[16]   Mistaken diagnosis of keratoconus because of corneal warpage induced by hydrogel lens wear [J].
Tseng, Santos Shan-Yu ;
Hsiao, John Ching-Jen ;
Chang, David Chao-Kai .
CORNEA, 2007, 26 (09) :1153-1155
[17]  
Wang Xiaohong, 2002, CLAO Journal, V28, P169
[18]  
WILSON S E, 1990, CLAO Journal, V16, P177