Comparative Performance Analysis of the DC-AC Converter Control System Based on Linear Robust or Nonlinear PCH Controllers and Reinforcement Learning Agent

被引:3
作者
Nicola, Marcel [1 ]
Nicola, Claudiu-Ionel [1 ]
机构
[1] Natl Inst Res Dev & Testing Elect Engn ICMET Craio, Res & Dev Dept, Craiova 200746, Romania
关键词
robust control; Port Controlled Hamiltonian; Reinforcement learning; DC-AC converter; grid;
D O I
10.3390/s22239535
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Starting from the general topology and the main elements that connect a microgrid represented by a DC power source to the main grid, this article presents the performance of the control system of a DC-AC converter. The main elements of this topology are the voltage source inverter represented by a DC-AC converter and the network filters. The active Insulated Gate Bipolar Transistor (IGBT) or Metal-Oxide-Semiconductor Field-Effect Transistor (MOSFET) elements of the DC-AC converter are controlled by robust linear or nonlinear Port Controlled Hamiltonian (PCH) controllers. The outputs of these controllers are modulation indices which are inputs to a Pulse-Width Modulation (PWM) system that provides the switching signals for the active elements of the DC-AC converter. The purpose of the DC-AC converter control system is to maintain u(d) and u(q) voltages to the prescribed reference values where there is a variation of the three-phase load, which may be of balanced/unbalanced or nonlinear type. The controllers are classic PI, robust or nonlinear PCH, and their performance is improved by the use of a properly trained Reinforcement Learning-Twin Delayed Deep Deterministic Policy Gradient (RL-TD3) agent. The performance of the DC-AC converter control systems is compared using performance indices such as steady-state error, error ripple and Total Harmonic Distortion (THD) current value. Numerical simulations are performed in Matlab/Simulink and conclude the superior performance of the nonlinear PCH controller and the improvement of the performance of each controller presented by using an RL-TD3 agent, which provides correction signals to improve the performance of the DC-AC converter control systems when it is properly trained.
引用
收藏
页数:32
相关论文
共 28 条
[1]  
[Anonymous], 1995, IEEE Recommended Practice for Electric Power Distribution for, P1, DOI DOI 10.1109/IEEESTD.2015.7024095.12
[2]  
[Anonymous], MATHWORKS REINFORCEM
[3]  
[Anonymous], MATLAB CENTRAL FILE
[4]   A Bidirectional Grid-Connected DC-AC Converter for Autonomous and Intelligent Electricity Storage in the Residential Sector [J].
Aouichak, Ismail ;
Jacques, Sebastien ;
Bissey, Sebastien ;
Reymond, Cedric ;
Besson, Teo ;
Le Bunetel, Jean-Charles .
ENERGIES, 2022, 15 (03)
[5]   Deterioration of Electrical Load Forecasting Models in a Smart Grid Environment [J].
Azeem, Abdul ;
Ismail, Idris ;
Jameel, Syed Muslim ;
Romlie, Fakhizan ;
Danyaro, Kamaluddeen Usman ;
Shukla, Saurabh .
SENSORS, 2022, 22 (12)
[6]  
Beale M.H., 2020, Deep Learning Toolbox TM User' s Guide
[7]  
Brandimarte P., 2021, SHORTEST PATHS REINF, P185
[8]   Control Technique for Transformerless Regenerative Testing of Grid-Connected Power Converters [J].
Das, Partha Pratim ;
Chatterjee, Debanjan ;
Kadavelugu, Arun K. .
2022 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2022, :1430-1436
[9]   Robustness of Model-Predictive and Passivity-Based Control in the Three-Phase DC/AC Converter Application [J].
Dyga, Lukasz ;
Alhasheem, Mohammed ;
Davari, Pooya ;
Rymarski, Zbigniew .
APPLIED SCIENCES-BASEL, 2022, 12 (09)
[10]   Day Ahead Optimal Dispatch Schedule in a Smart Grid Containing Distributed Energy Resources and Electric Vehicles [J].
Fotopoulou, Maria ;
Rakopoulos, Dimitrios ;
Blanas, Orestis .
SENSORS, 2021, 21 (21)