Potentiometric Study of Coated Graphite Electrode and Polymeric Membrane Electrode for the Determination of Sm3+Ion

被引:7
作者
Upadhyay, Anjali [1 ]
Singh, A. K. [1 ]
Jain, A. K. [1 ]
Gupta, Vinod Kumar [1 ]
Bandi, Koteswara Rao [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
Polymeric membrane electrodes; Coated graphite electrodes; Potentiometric electrodess; Ion selective electrodes; ION-SELECTIVE ELECTRODES; SCHIFF-BASES; PVC MEMBRANE; URANYL IONS; SENSOR; SAMARIUM(III); DIBENZO-24-CROWN-8; BORATOPHOSPHATE; FABRICATION; IONOPHORES;
D O I
10.1002/elan.201200050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Preliminary studies on the two Schiff bases N2-((3H-indol-3-yl)methylene)-6-phenyl-1,3,5-triazine-2,4-diamine (L1) and N2,N4-bis((3H-indol-3-yl)methylene)-6-phenyl-1,3,5-triazine-2,4-diamine (L2) have shown that they can act as Sm3+ selective electrodes. The performances of a polymeric membrane electrode and a coated graphite electrode based on L2 were compared and the CGE proved to be better, as it shows a low detection limit of 1.8x10-8 mol?L-1, a Nernstian slope of 19.6 +/- 0.4 mV decade-1 of activity with a response time of 11 s in the pH range of 3.09.0. The CGE was used to determine Sm3+ in medicinal plants and soil samples. It was also used to determine fluoride ions in mouthwash samples and in toothpaste.
引用
收藏
页码:1630 / 1638
页数:9
相关论文
共 54 条
  • [21] Gschneidner K.A., 1979, HDB PHYS CHEM RARE E
  • [22] Gupta VK, 2009, INT J ELECTROCHEM SC, V4, P156
  • [23] Nano level detection of Cd(II) using poly(vinyl chloride) based membranes of Schiff bases
    Gupta, Vinod K.
    Al Hayat, Maysoon
    Singh, Ashok K.
    Pal, Manoj K.
    [J]. ANALYTICA CHIMICA ACTA, 2009, 634 (01) : 36 - 43
  • [24] A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of N,N′-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine
    Gupta, Vinod Kumar
    Singh, A. K.
    Gupta, Barkha
    [J]. ANALYTICA CHIMICA ACTA, 2006, 575 (02) : 198 - 204
  • [25] Gupta VK, 1999, ELECTROANAL, V11, P573, DOI 10.1002/(SICI)1521-4109(199906)11:8<573::AID-ELAN573>3.0.CO
  • [26] 2-Z
  • [27] Cadmium(II)-selective sensors based on dibenzo-24-crown-8 in PVC matrix
    Gupta, VK
    Kumar, P
    [J]. ANALYTICA CHIMICA ACTA, 1999, 389 (1-3) : 205 - 212
  • [28] Porphyrins as carrier in PVC based membrane potentiometric sensors for nickel(II)
    Gupta, VK
    Jain, AK
    Singh, LP
    Khurana, U
    [J]. ANALYTICA CHIMICA ACTA, 1997, 355 (01) : 33 - 41
  • [29] Anion recognition through modified calixarenes: a highly selective sensor for monohydrogen phosphate
    Gupta, VK
    Ludwig, R
    Agarwal, S
    [J]. ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) : 213 - 218
  • [30] Gupta VK, 2002, ELECTROANAL, V14, P1127, DOI 10.1002/1521-4109(200208)14:15/16<1127::AID-ELAN1127>3.0.CO