摘要
Purpose: To investigate the image quality and vessel depiction of renal MRA with integrated parallel imaging techniques (iPAT) using acceleration factors of 2 and 3. Materials and Methods: In this prospective study renal MRA was performed on 14 and 12 patients with acceleration factors of 3 and 2, respectively. For the MRA a 3D-GRE sequence with an acquired spatial resolution of 0.9 x 0.8 x 1.0 mm(3) was applied (TR/TE = 3.79 msec/1.39 msec, FOV = 400 mm x 320 mm, acquired matrix = 512 x 384, flip angle = 25 degrees) on a 32-channel 1.5T MR scanner. The acquisition time was 26 seconds with iPAT 2, and 19 seconds with iPAT3. All parameters other than acquisition time and acceleration factor were kept constant. To assess the signal-to-noise ratio (SNR) we performed repetitive phantom measurements using iPAT 2 and 3. The images were rated by two radiologists in terms of noise, artifacts, and the quality of vessel depiction for the proximal, segmental, and subsegmental renal artery. A Mann-Whitney U test and kappa-test were used for statistical analysis Results: SNR decreased significantly with iPAT 3 in the phantom measurements. The two readers found no difference in noise, but significantly fewer artifacts with iPAT 3. The depiction of segmental vessels was significantly better for both readers with iPAT3, and the subsegmental vessels were rated significantly better by one reader. iPAT 3 also resulted in a better interreader agreement. Conclusion: The use of iPAT 3 for renal MRA enables a better depiction of the distal parts of the renal artery. The decrease in SNR is not diagnostically imapiring.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 20 条
[1]  
Chen Q, 2004, RADIOLOGY, V231, P893, DOI [10.1148/radiol.2313021113, 10.1148/radio1:2313021113]
[2]   Using a 1 M Gd-chelate (gadobutrol) for total-body three-dimensional MR angiography:: preliminary experience [J].
Goyen, M ;
Herborn, CU ;
Vogt, FM ;
Kröger, K ;
Verhagen, R ;
Yang, F ;
Bosk, S ;
Debatin, JF ;
Ruehm, SG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (05) :565-571
[3]   0.5 M Gd chelate (Magnevist®) versus 1.0 M Gd chelate (Gadovist®):: Dose-independent effect on image quality of pelvic three-dimensional MR-angiography [J].
Goyen, M ;
Lauenstein, TC ;
Herborn, CU ;
Debatin, JF ;
Bosk, S ;
Ruehm, SG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) :602-607
[4]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[5]   CT evaluation of renovascular disease [J].
Kawashima, A ;
Sandler, CM ;
Ernst, RD ;
Tamm, EP ;
Goldman, SM ;
Fishman, EK .
RADIOGRAPHICS, 2000, 20 (05) :1321-1340
[6]   Single-dose breath-hold gadolinium-enhanced three-dimensional MR angiography of the renal arteries [J].
Lee, VS ;
Rofsky, NM ;
Krinsky, GA ;
Stemerman, DH ;
Weinreb, JC .
RADIOLOGY, 1999, 211 (01) :69-78
[7]  
Michaely Henrik J, 2005, Magn Reson Imaging Clin N Am, V13, P131, DOI 10.1016/j.mric.2004.12.007
[8]   Is magnetic resonance angiography useful in renovascular disease? [J].
Prasad, S ;
Bannister, K ;
Taylor, J .
INTERNAL MEDICINE JOURNAL, 2003, 33 (03) :84-90
[9]   GADOLINIUM-ENHANCED MR AORTOGRAPHY [J].
PRINCE, MR .
RADIOLOGY, 1994, 191 (01) :155-164
[10]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO