A rapid and sensitive liquid chromatography/negative ion tandem mass spectrometry method for the determination of an indolocarbazole in human plasma using internal standard (IS) 96-well diatomaceous earth plates for solid-liquid extraction

被引:28
|
作者
Wang, AQ [1 ]
Zeng, W [1 ]
Musson, DG [1 ]
Rogers, JD [1 ]
Fisher, AL [1 ]
机构
[1] Merck & Co Inc, Merck Res Labs, W Point, PA 19486 USA
关键词
D O I
10.1002/rcm.669
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the quantitation of a novel topoisomerase I inhibitor (indolocarbazole derivative I) in human plasma was developed to support clinical studies. Drug and internal standard were isolated from plasma by solid-liquid extraction using 96-well diatomaceous earth plates. Various extraction solvents were evaluated for extraction of I and 9% isopropyl alcohol (IPA) in methyl-tert-butyl ether (MtBE) was chosen as the optimal extraction solvent. The sensitivity of this LC/MS/MS method is 10x higher in negative ion mode using alkaline conditions than in positive ion mode using a wide range of pH's. A mobile phase with 2 mM ammonium hydroxide enhanced the sensitivity in negative ion mode over other volatile bases. The calibration curve for compound I is linear over the range 0.05-200 ng/mL in plasma and the lower limit of quantification (LLOQ) of the assay is 0.05 ng/mL, when 0.25 mL of plasma is processed. The method was fully validated and successfully applied to plasma samples from clinical studies. Performing chromatography at high pH, for enhanced negative ion sensitivity, eliminates the need for post-column addition of base. Furthermore, the 96-well diatomaceous earth plate extraction offers the following advantages over liquid-liquid extraction (LLE) or solid-phase extraction (SPE): clean sample extracts with reduced sample preparation time; increased sample throughput; no conditioning or washing steps; and a neutral eluate applicable to acid/base labile compounds. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:975 / 981
页数:7
相关论文
共 50 条
  • [1] A rapid and sensitive liquid chromatography/negative ion tandem mass spectrometry method for the determination of an indolocarbazole in human plasma using 96-well diatomaceous earth plates for solid-liquid extraction (vol 16, pg 975, 2002)
    Wang, AQ
    Zeng, W
    Musson, DG
    Rogers, JD
    Fisher, AL
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (16) : 1610 - 1610
  • [2] A highly automated 96-well solid phase extraction and liquid chromatography/tandem mass spectrometry method for the determination of fentanyl in human plasma
    Shou, WZ
    Jiang, XY
    Beato, BD
    Weng, ND
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (07) : 466 - 476
  • [3] Development of a rapid method for the determination of glimepiride in human plasma using liquid-liquid extraction based on 96-well format micro-tubes and liquid chromatography/tandem mass spectrometry
    Dotsikas, Y
    Kousoulos, C
    Tsatsou, G
    Loukas, YL
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (14) : 2055 - 2061
  • [4] A rapid and sensitive liquid chromatography/positive ion tandem mass spectrometry method for the determination of cimetropium in human plasma by liquid-liquid extraction
    Lee, Heon-Woo
    Park, Wan-Su
    Kim, Yong-Won
    Cho, Sung-Hee
    Kim, Sung-Su
    Seo, Ji-Hyung
    Lee, Kyung-Tae
    JOURNAL OF MASS SPECTROMETRY, 2006, 41 (07): : 855 - 860
  • [5] Automated 96-well liquid-liquid back extraction liquid chromatography-tandem mass spectrometry method for the determination of ABT-202 in human plasma
    Xu, NX
    Kim, GE
    Gregg, H
    Wagdy, A
    Swaine, BA
    Chang, MS
    El-Shourbagy, TA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (01) : 189 - 195
  • [6] Liquid-liquid extraction using 96-well plate format in conjunction with liquid chromatography/tandem mass spectrometry for quantitative determination of methylphenidate (Ritalin®) in human plasma
    Ramos, L
    Bakhtiar, R
    Tse, FLS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (09) : 740 - 745
  • [7] Stabilization and determination of a PPAR agonist in human urine using automated 96-well liquid-liquid extraction and liquid chromatography/tandem mass spectrometry
    Groff, Michelle
    Riffel, Kerry
    Song, Hengchang
    Lo, Man-Wai
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 842 (02): : 122 - 130
  • [8] Development and validation of a rapid 96-well format based liquid-liquid extraction and liquid chromatography-tandem mass spectrometry analysis method for ondansetron in human plasma
    Dotsikas, Yannis
    Kousoulos, Constantinos
    Tsatsou, Georgia
    Loukas, Yannis L.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 836 (1-2): : 79 - 82
  • [9] Validation of a sensitive and automated 96-well solid-phase extraction liquid chromatography-tandem mass spectrometry method for the determination of desloratadine and 3-hydroxydesloratadine in human plasma
    Yang, LY
    Clement, RP
    Kantesaria, B
    Reyderman, L
    Beaudry, F
    Grandmaison, C
    Di Donato, L
    Masse, R
    Rudewicz, PJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02): : 229 - 240
  • [10] Simultaneous quantitation of enalapril and enalaprilat in human plasma by 96-well solid-phase extraction and liquid chromatography/tandem mass spectrometry
    Lee, J
    Son, J
    Lee, M
    Lee, KT
    Kim, DH
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (11) : 1157 - 1162