Novel potentiometric sensors based on polysulfone immobilized metallothioneins as metal-ionophores

被引:29
作者
Gonzalez-Bellavista, Anna [5 ]
Atrian, Silvia [3 ,4 ]
Munoz, Maria [2 ]
Capdevila, Merce [1 ]
Fabregas, Esteve [5 ]
机构
[1] Univ Autonoma Barcelona, Fac Ciencias, Dept Quim, Bioinorgan Chem Grp, Bellaterra 08193, BCN, Spain
[2] Univ Autonoma Barcelona, Fac Ciencias, Dept Quim, Separat Tech Grp, Bellaterra 08193, BCN, Spain
[3] Univ Barcelona, Inst Biomed, Barcelona, Spain
[4] Univ Barcelona, Fac Biol, Dept Genet, Genet Grp, E-08028 Barcelona, Spain
[5] Univ Autonoma Barcelona, Fac Ciencias, Dept Quim, Sensors & Biosensors Grp, Bellaterra 08193, BCN, Spain
关键词
Metallothionein; Polysulfone membrane; Potentiometric biosensor; Ion-selective electrode; Silver detection; ION-SELECTIVE ELECTRODES; BIOAVAILABLE HEAVY-METALS; PROTEIN-BASED BIOSENSORS; MEMBRANE ELECTRODES; PVC; MATRICES; CARRIERS; BINDING;
D O I
10.1016/j.talanta.2008.09.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We show here the use of immobilized metal-binding biomolecules for metal analysis by using novel potentiometric sensors. To this end and as a model, Ag+-ISEs were developed using polysulfone matrix embedding metallothioneins as ionophores (mouse MT1 (P1) or sea urchin SpMTA (P2)). Polysulfone, a porous polymer that was not used until the present in potentiometric biosensors, has the advantage of being compatible with biological materials. Also, the phase inversion procedure allows protein incorporation into the membrane with minima alterations, since it always remains in the aqueous phase. Construction of these biosensors required small amounts of protein; they can be dry-stored and have long lifetimes. They exhibited linear responses with slopes of ca. 61 mV per decade within the 10(-5) to 10(-2) M Ag+ concentration range, detection limits of about 10-5 M, and worked in the 2-to-8 pH range. Except for Hg2+, the Pb2+, Zn2+, Cd2+, Cu2+ cations do not interfere with Ag+ determination. Significantly, different affinities of Pb2+ and Zn2+ towards P1- and P2-ISE were found, in good correlation with the higher affinity of these cations towards SpMTA than to MT1. Consequently, the distinct metal-binding features of each MT are conserved and determine the differential properties of their biosensors. These results open a broad range of possibilities for the use of proteins as ionophores in what could be considered a new type of potentiometric biosensor if their response mechanism is taken into account. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1528 / 1533
页数:6
相关论文
共 46 条
[1]   RESPONSE CHARACTERISTICS OF CONDUCTIVE POLYMER COMPOSITE SUBSTRATE ALL-SOLID-STATE POLY(VINYL CHLORIDE) MATRIX MEMBRANE ION-SELECTIVE ELECTRODES IN AERATED AND NITROGEN-SATURATED SOLUTIONS [J].
ALEGRET, S ;
FLORIDO, A .
ANALYST, 1991, 116 (05) :473-476
[2]  
ALEGRET S, 1987, QUIM ANAL, V6, P176
[3]   Silver selective electrodes based on methyl-2-pyridyl ketone oxime, phenyl-2-pyridyl ketone oxime and bis[2-(o-carboxythiophenoxy)methyl]-4-bromo-1-methoxybenzene carriers [J].
Amini, MK ;
Ghaedi, M ;
Rafi, A ;
Mohamadpoor-Baltork, L ;
Niknam, K .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (03) :669-676
[4]   DETERMINATION OF COMPLEX-FORMATION CONSTANTS OF NEUTRAL CATION-SELECTIVE IONOPHORES IN SOLVENT POLYMERIC MEMBRANES [J].
BAKKER, E ;
WILLER, M ;
LERCHI, M ;
SEILER, K ;
PRETSCH, E .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :516-521
[5]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[6]   Bacterial metal-resistance proteins and their use in biosensors for the detection of bioavailable heavy metals [J].
Bontidean, I ;
Lloyd, JR ;
Hobman, JL ;
Wilson, JR ;
Csöregi, E ;
Mattiasson, B ;
Brown, NL .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2000, 79 (1-4) :225-229
[7]   Detection of heavy metal ions at femtomolar levels using protein-based biosensors [J].
Bontidean, I ;
Berggren, C ;
Johansson, G ;
Csöregi, E ;
Mattiasson, B ;
Lloyd, JA ;
Jakeman, KJ ;
Brown, NL .
ANALYTICAL CHEMISTRY, 1998, 70 (19) :4162-4169
[8]   Novel synthetic phytochelatin-based capacitive biosensor for heavy metal ion detection [J].
Bontidean, I ;
Ahlqvist, J ;
Mulchandani, A ;
Chen, W ;
Bae, W ;
Mehra, RK ;
Mortari, A ;
Csöregi, E .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :547-553
[9]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[10]   New materials for electrochemical sensing .1. Rigid conducting composites [J].
Cespedes, F ;
MartinezFabregas, E ;
Alegret, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (07) :296-304