Preconcentration of lead with Amberlite XAD-2 and Amberlite XAD-7 based chelating resins for its determination by flame atomic absorption spectrometry

被引:158
作者
Tewari, PK [1 ]
Singh, AK [1 ]
机构
[1] Indian Inst Technol, Dept Chem, New Delhi 110016, India
关键词
Amberlite XAD-2; Amberlite XAD-7; lead; atomic absorption spectrometry; chelating resins; preconcentration; chromotropic acid; pyrocatechol; thiosalicylic acid; xylenol orange;
D O I
10.1016/S0039-9140(01)00606-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four chelating matrices prepared by coupling Amberlite XAD-2 with chromotropic acid (AXAD-2-CA or 1), pyrocatechol (AXAD-2-PC or 2) and thiosalicylic acid (AXAD-2-TSA or 3) through azo spacer and impregnation of Amberlite XAD-7 with xylenol orange (AXAD-7-XO or 4) have been studied for enrichment of lead(II). All the four resins quantitatively sorb Pb(II) at pH 3.0-8.0 when the flow rate is maintained between 2 and 10 ml min(-1). HNO, (0.5-4.0 M) instantaneously elutes Pb(II) from all the four chelating resins. The sorption capacity is in the range 16.0-186.0 mumol g(-1) and loading half time (t(1/2)) between 3.2 and 15.5 min. The tolerance limits of electrolytes (NaCl, NaBr, NaNO3, Na2SO4, Na3PO4) and cations (Ca and Mg) are reported. Phosphate interferes in the sorption with 3 and 4. The limit of detection and limit of quantification have been found to be in the ranges 2.44-7.87 and 2.76-8.64 ng ml(-1), respectively. Lead has been determined in river (RSD similar to2.6-12.8%) and tap (RSD similar to1.8-7.2%) water samples. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:735 / 744
页数:10
相关论文
共 38 条
[1]   IMMOBILIZED 8-OXINE UNITS ON DIFFERENT SOLID SORBENTS FOR THE UPTAKE OF METAL TRACES [J].
ABOLLINO, O ;
MENTASTI, E ;
PORTA, V ;
SARZANINI, C .
ANALYTICAL CHEMISTRY, 1990, 62 (01) :21-26
[2]   Determination of metals in highly saline matrices by solid-phase extraction and slurry-sampling inductively coupled plasma-atomic emission spectrometry [J].
Abollino, O ;
Aceto, M ;
Bruzzoniti, MC ;
Mentasti, E ;
Sarzanini, C .
ANALYTICA CHIMICA ACTA, 1998, 375 (03) :293-298
[3]  
Bilba D, 1998, CROAT CHEM ACTA, V71, P155
[4]   COLUMN PRECONCENTRATION OF TRACE-METALS FROM SEA-WATER WITH MACROPOROUS RESINS IMPREGNATED WITH LIPOPHILIC TETRAAZA MACROCYCLES [J].
BLAIN, S ;
APPRIOU, P ;
HANDEL, H .
ANALYST, 1991, 116 (08) :815-820
[5]   PRECONCENTRATION AND SEPARATION OF METAL-IONS BY MEANS OF AMBERLITE XAD-2 LOADED WITH PYROCATECHOL VIOLET [J].
BRAJTER, K ;
OLBRYCHSLESZYNSKA, E ;
STASKIEWICZ, M .
TALANTA, 1988, 35 (01) :65-67
[6]   Preparation and properties of a new chelating resin containing imidazolyl azo groups [J].
Chattopadhyay, P ;
Sinha, C ;
Pal, DK .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (04) :368-372
[7]   SYNTHESIS AND ANALYTICAL CHARACTERIZATION OF A CHELATING RESIN LOADED WITH DITHIZONE [J].
CHWASTOWSKA, J ;
KOSIARSKA, E .
TALANTA, 1988, 35 (06) :439-442
[8]   Chelating resins and their applications in the analysis of trace metal ions [J].
Garg, BS ;
Sharma, RK ;
Bhojak, N ;
Mittal, S .
MICROCHEMICAL JOURNAL, 1999, 61 (02) :94-114
[9]   The effect of freshwater UV-irradiation prior to resin preconcentration of trace metals [J].
Guéguen, C ;
Belin, C ;
Thomas, BA ;
Monna, F ;
Favarger, PY ;
Dominik, J .
ANALYTICA CHIMICA ACTA, 1999, 386 (1-2) :155-159
[10]   PREPARATION OF AMBERLITE XAD RESINS COATED WITH DITHIOSEMICARBAZONE COMPOUNDS AND PRECONCENTRATION OF SOME METAL-IONS [J].
HOSHI, S ;
FUJISAWA, H ;
NAKAMURA, K ;
NAKATA, S ;
UTO, M ;
AKATSUKA, K .
TALANTA, 1994, 41 (04) :503-507