Different loss of BMD using uncemented press-fit and whole polyethylene cups fixed with cement -: Repeated DXA studies in 96 hips randomized to 3 types of fixation

被引:49
作者
Digas, G [1 ]
Kärrholm, J [1 ]
Thanner, J [1 ]
机构
[1] Sahlgrenska Univ Hosp, Dept Orthoped, SE-41345 Gothenburg, Sweden
关键词
D O I
10.1080/17453670610045948
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background In cemented THA, aseptic loosening of the cup is more common than loosening of the stem, while periprosthetic osteolysis of the socket resulting in difficult reconstruction problems has emerged as the most significant problem with cementless cup fixation. Patients and methods 90 patients (96 hips) scheduled for THA were stratified in three groups according to the method of fixation of the acetabular component: acrylic bone cement with fluoride (Cemex-F), porous-coated press-fit cup with ceramic coating (Trilogy, uncemented) and acrylic cement with gentamicin (Palacos). All patients received the Spectron EF stem. Acetabular bone mineral density was measured with dual-energy X-ray absorptiometry (DXA) 1 week postoperatively, and after 12 and 24 months. The periprosthetic BMD was evaluated in 5 ROIs positioned around the acetabular component. Results In the uncemented sockets, the BMD had decreased proximally and medially to the cup after 2 years. The difference was significant in the proximal region as compared to the control group (Palacos). No difference was noted between the 2 groups with cemented components after 2 years. Stepwise linear regression analysis showed that loss of periprosthetic BMD in the proximal high-pressure region after 2 years increased with higher postoperative BMD and when the uncemented design had been used. Interpretation Contrary to previous studies of cemented stems, the use of fluoride cement did not influence the periprosthetic BMD 2 years after the examination. Increased loss of BMD with use of uncemented press-fit cups in the region in which osteolytic lesions are commonly found suggests that stress shielding may initiate the development of this complication. Longer follow-up will, however, be necessary to substantiate this hypothesis.
引用
收藏
页码:218 / 226
页数:9
相关论文
共 31 条
[1]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[2]  
Archibeck M J, 2001, Instr Course Lect, V50, P185
[3]   BIOPHYSICAL STUDY OF BONE-MINERAL IN BIOPSIES OF OSTEOPOROTIC PATIENTS BEFORE AND AFTER LONG-TERM TREATMENT WITH FLUORIDE [J].
BAUD, CA ;
VERY, JM ;
COURVOISIER, B .
BONE, 1988, 9 (06) :361-365
[4]   Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty - A five-year longitudinal study [J].
Brodner, W ;
Bitzan, P ;
Lomoschitz, F ;
Krepler, P ;
Jankovsky, R ;
Lehr, S ;
Kainberger, F ;
Gottsauner-Wolf, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (01) :20-26
[5]   Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement [J].
Bugbee, WD ;
Culpepper, WJ ;
Engh, CA ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1007-1012
[6]   Results of Charnley total hip arthroplasty at a minimum of thirty years - A concise follow-up of a previous report [J].
Callaghan, JJ ;
Templeton, JE ;
Liu, SS ;
Pedersen, DR ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (04) :690-695
[7]   Fluoride-containing acrylic bone cement in total hip arthroplasty.: Randomized evaluation of 97 stems using radiostereometry and dual-energy X-ray absorptiometry [J].
Digas, G ;
Thanner, J ;
Anderberg, C ;
Kärrholm, J .
JOURNAL OF ARTHROPLASTY, 2005, 20 (06) :784-792
[8]   Bioactive cement or ceramic/porous coating vs. conventional cement to obtain early stability of the acetabular cup -: Randomised study of 96 hips followed with radiostereometry [J].
Digas, G ;
Thanner, J ;
Anderberg, C ;
Kärrholm, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (05) :1035-1043
[9]   Increase in early polyethylene wear after sterilization with ethylene oxide -: Radiostereometric analyses of 201 total hips [J].
Digas, G ;
Thanner, J ;
Nivbrant, B ;
Röhrl, S ;
Ström, H ;
Kärrholm, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (05) :531-541
[10]  
HUISKES R, 1987, ACTA ORTHOP SCAND, V58, P620