Use of three-dimensional speckle tracking to assess left ventricular myocardial mechanics: inter-vendor consistency and reproducibility of strain measurements

被引:78
作者
Badano, Luigi P. [1 ]
Cucchini, Umberto [1 ]
Muraru, Denisa [1 ]
Al Nono, Osama [1 ]
Sarais, Cristiano [1 ]
Iliceto, Sabino [1 ]
机构
[1] Univ Padua, Dept Cardiac Vasc & Thorac Sci, I-35128 Padua, Italy
关键词
Three-dimensional echocardiography; Strain; Left ventricular function; Myocardial mechanics; Myocardial deformation; Speckle tracking; Reproducibility; Deformation imaging; MOTION TRACKING; AREA TRACKING; ECHOCARDIOGRAPHY; DEFORMATION;
D O I
10.1093/ehjci/jes184
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Since there is insufficient data available about the inter-vendor consistency of three-dimensional (3D) speckle-tracking (STE) measurements, we undertook this study to (i) assess the inter-vendor consistency of 3D LV global strain values obtained using two different scanners; (ii) identify the sources of inter-vendor inconsistencies, if any; and (iii) compare their respective intrinsic variability. Sixty patients (38 12 years, 64 males) with a wide range of LV end-diastolic volumes (from 74 to 205 ml) and ejection fractions (from 17 to 70) underwent two 3D LV data set acquisitions using VividE9 and Artida ultrasound systems. Global longitudinal (L?), radial (R?), circumferential (C?) and area (A?) strain values were obtained offline using the corresponding 3D STE softwares. Despite being significantly different, L? showed the closest values between the two platforms (bias 1.5, limits of agreement(LOA) from 2.9 to 5.9, P 0.05). Artida produced significantly higher values of both C? and A? than VividE9 (bias 6.6, LOA: 14.1 to 0.9, and bias 6.0, LOA 28.28.6, respectively, P 0.001). Conversely, R? values obtained with Artida were significantly lower than those measured using VividE9 platform (bias 24.2, LOA: 1.549.9, P 0.001). All strain components showed good reproducibility (intra-class correlation coefficients: 0.820.98), except for R? by Artida, which showed only a moderate reproducibility. Apart from L?, the inter-vendor agreement of R?, C? and A? measured with Artida and VividE9 was poor. Reference values should be specific for each system and baseline and follow-up data in longitudinal studies should be obtained using the same 3D STE platform.
引用
收藏
页码:285 / 293
页数:9
相关论文
共 23 条
  • [1] [Anonymous], 2011, 4D STRAIN ADV RES AP
  • [2] Reproducibility and Inter-Vendor Variability of Left Ventricular Deformation Measurements by Three-Dimensional Speckle-Tracking Echocardiography
    Gayat, Etienne
    Ahmad, Homaa
    Weinert, Lynn
    Lang, Roberto M.
    Mor-Avi, Victor
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (08) : 878 - 885
  • [3] Reliability of left ventricular volumes and function measurements using three-dimensional speckle tracking echocardiography
    Kleijn, Sebastiaan A.
    Aly, Mohamed F. A.
    Terwee, Caroline B.
    van Rossum, Albert C.
    Kamp, Otto
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (02) : 159 - 168
  • [4] Recommendations for chamber quantification
    Lang, Roberto M.
    Bierig, Michelle
    Devereux, Richard B.
    Flachskampf, Frank A.
    Foster, Elyse
    Pellikka, Patricia A.
    Picard, Michael H.
    Roman, Mary J.
    Seward, James
    Shanewise, Jack
    Solomon, Scott
    Spencer, Kirk T.
    Sutton, Martin St. John
    Stewart, William
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (02): : 79 - 108
  • [5] Novel Area Strain Based on Three-Dimensional Wall Motion Analysis for Assessment of Global Left Ventricular Performance after Repair of Tetralogy of Fallot
    Li, Shu-na
    Wong, Sophia J.
    Cheung, Yiu-fai
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (08) : 819 - 825
  • [6] Three-dimensional simultaneous strain-volume analysis describes left ventricular remodelling and its progression: a pilot study
    Lilli, Alessio
    Baratto, Marco Tullio
    Del Meglio, Jacopo
    Chioccioli, Marco
    Magnacca, Massimo
    Svetlich, Carla
    Ottonelli, Andrea Ghidini
    Poddighe, Rosa
    Comella, Alessandro
    Casolo, Giancarlo
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (07): : 520 - 527
  • [7] Quantitative Evaluation of Regional Left Ventricular Function Using Three-Dimensional Speckle Tracking Echocardiography in Patients With and Without Heart Disease
    Maffessanti, Francesco
    Nesser, Hans-Joachim
    Weinert, Lynn
    Steringer-Mascherbauer, Regina
    Niel, Johannes
    Gorissen, Willem
    Sugeng, Lissa
    Lang, Roberto M.
    Mor-Avi, Victor
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (12) : 1755 - 1762
  • [8] Assessment of left ventricular function by different speckle-tracking software
    Manovel, Ana
    Dawson, David
    Smith, Benjamin
    Nihoyannopoulos, Petros
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (05): : 417 - 421
  • [9] Consistency of myocardial deformation imaging between vendors
    Marwick, Thomas H.
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (05): : 414 - 416
  • [10] Current and Evolving Echocardiographic Techniques for the Quantitative Evaluation of Cardiac Mechanics: ASE/EAE Consensus Statement on Methodology and Indications Endorsed by the Japanese Society of Echocardiography
    Mor-Avi, Victor
    Lang, Roberto M.
    Badano, Luigi P.
    Belohlavek, Marek
    Cardim, Nuno Miguel
    Derumeaux, Genevieve
    Galderisi, Maurizio
    Marwick, Thomas
    Nagueh, Sherif F.
    Sengupta, Partho P.
    Sicari, Rosa
    Smiseth, Otto A.
    Smulevitz, Beverly
    Takeuchi, Masaaki
    Thomas, James D.
    Vannan, Mani
    Voigt, Jens-Uwe
    Zamorano, Jose Luis
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (03): : 167 - 205