Scintillation sensing of 18F-FDG for the detection of metabolically active atherosclerotic plaque

被引:0
|
作者
Burke, Michael [1 ]
Dennis, Kendall [1 ]
Benscoter, Mark [2 ]
Lerman, Amir [3 ]
Sandhu, Gurpreet [3 ]
Franchi, Federico [3 ]
Rodriguez-Porcel, Martin [4 ]
机构
[1] Mayo Clin, Div Engn, Rochester, MN 55902 USA
[2] Mayo Clin, Dept Biomed Engn, Div Engn, Rochester, MN 55902 USA
[3] Mayo Clin, Dept Cardiovasc Dis, Rochester, MN 55902 USA
[4] Mayo Clin, Dept Cardiovasc Dis, Dept Biomed Engn, Rochester, MN 55902 USA
来源
2017 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) | 2017年
关键词
optical scintillating fiber; atherosclerosis; atherosclerotic plaque; fluorodeoxyglucose; macrophages;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Atherosclerosis and its consequences are the main cause of mortality in the United States and the western world. Detection of metabolically active regions of atherosclerotic plaque can provide insights on those plaques that are prone to rupture, leading to a tissue infarction. The metabolic activity of these plaques can be identified using positron emission tomography (PET). However, such detection has been elusive in the coronary arteries due to motion and detection sensitivity. One of the techniques capable of improving precision as an affordable alternative is the use of an optical scintillating fiber for the detection of 18-Fluorine Fluorodeoxyglucose (F-18-FDG), a compound that is accumulated in metabolically active areas of the atherosclerotic plaque. Here we report on a prototype scintillating fiber detection system designed to characterize the beta emission, particularly positron emission, by F-18-FDG. We demonstrate the ability to effectively measure the presence of F-18-FDG contained in-vivo along with the ability discriminate against ambient light based on energy. This paper presents a catheter-based hardware and software platform based on the use of a scintillating fiber optic catheter. The system measures a short (2-3 ns) burst of photons that are generated by the stimulation of the plastic scintillating fiber by a positron (633 kEv) emitted by the radioactive compound. It can be used to determine the presence of F-18-FDG in-vivo and accurately detect the active decay as the F-18-FDG retained in the metabolically active plaque. The proposed instrument was tested in-vitro and its sensitivity was also measured in-vivo. The developed system may be used in the detection of F-18-FDG, as surrogate of inflammation, providing critical in-vivo information of the metabolism in areas of inflammation.
引用
收藏
页码:67 / 71
页数:5
相关论文
共 50 条
  • [1] Reproducibility of 'metabolically active volume' measurements with 18F-FDG and 18F-FLT PET
    Frings, Virginie
    De Langen, Joop
    Smit, Egbert
    Hoekstra, Otto
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [2] In vivo detection of atherosclerotic plaque in APOE-/- mice using 18F-FDG PET/CT imaging
    Sleiman, L.
    Thorn, S.
    Small, G.
    deKemp, R. A.
    DaSilva, J.
    Beanlands, R. S.
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (04) : 670 - 670
  • [3] In Vivo Monitoring of Atherosclerotic Evolution and Detection of Vulnerable Plaque in a Rabbit Model by 18F-FDG PET/CT
    Zhao, Quanming
    Zhao, Xuecheng
    Feng, Tingting
    Zhao, Xin
    Zhang, Mingduo
    Zhuang, Xucui
    CIRCULATION, 2012, 126 (21)
  • [4] The possible value of ~18F-FDG positron emission tomography/computerized tomography imaging in detection of atherosclerotic plaque
    Jianwei Yuan a
    b Office of Scientific Research Management
    JournalofNanjingMedicalUniversity, 2008, (01) : 61 - 65
  • [5] Atherosclerotic Plaque Detection With a Fluorescence/Radionuclide Intravascular Imaging System for 18F-FDG and 6-NBDG
    Zaman, Raiyan
    Kosuge, Hisanori
    Pratx, Guillem
    Carpenter, Colin
    Xing, Lei
    McConnell, Michael V.
    CIRCULATION, 2013, 128 (22)
  • [6] Detection of Vulnerable Atherosclerotic Plaque and Prediction of Thrombosis Events in a Rabbit Model Using 18F-FDG -PET/CT
    Zhao, Quan-ming
    Zhao, Xin
    Feng, Ting-ting
    Zhang, Ming-duo
    Zhuang, Xu-cui
    Zhao, Xue-cheng
    Li, Li-qin
    Li, De-peng
    Liu, Yu
    PLOS ONE, 2013, 8 (04):
  • [7] Variability in quantitative analysis of atherosclerotic plaque inflammation using 18F-FDG PET/CT
    Lensen, Karel-Jan D. F.
    van Sijl, Alper M.
    Voskuyl, Alexandre E.
    van der Laken, Conny J.
    Heymans, Martijn W.
    Comans, Emile F. I.
    Nurmohamed, Mike T.
    Smulders, Yvo M.
    Boellaard, Ronald
    PLOS ONE, 2017, 12 (08):
  • [8] Imaging atherosclerotic plaque in old and hyperlipidemic rabbits using 18F-FDG and PET.
    Odaka, K
    Yoshida, K
    Tadokoro, H
    Suzuki, K
    Irie, T
    Tanada, S
    Komuro, I
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 105P - 105P
  • [9] Non-calcified active atherosclerosis plaque detection with 18F-NaF and 18F-FDG PET/CT dynamic imaging
    Douhi, Abdelillah
    Al-enezi, Mamdouh S.
    Berrahmoune, Nousra
    Khalil, Abdelouahed
    Fulop, Tamas
    Nguyen, Michel
    Turcotte, Eric
    Croteau, Etienne
    Bentourkia, M'hamed
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (01) : 295 - 302
  • [10] Non-calcified active atherosclerosis plaque detection with 18F-NaF and 18F-FDG PET/CT dynamic imaging
    Abdelillah Douhi
    Mamdouh S. Al‑enezi
    Nousra Berrahmoune
    Abdelouahed Khalil
    Tamas Fulop
    Michel Nguyen
    Eric Turcotte
    Étienne Croteau
    M’hamed Bentourkia
    Physical and Engineering Sciences in Medicine, 2023, 46 : 295 - 302