Cerium oxide-graphene as the matrix for cholesterol sensor

被引:61
作者
Zhang, Meihe [1 ]
Yuan, Ruo [1 ]
Chai, Yaqin [1 ]
Wang, Cun [1 ]
Wu, Xiaoping [1 ]
机构
[1] Southwest Univ, Educ Minist, Coll Chem & Chem Engn, Key Lab Luminescence & Real Time Anal, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrogenerated chemiluminescence; Graphene; Luminol; Cerium oxide; Cholesterol biosensor; CHEMILUMINESCENT REACTION; HYDROGEN-PEROXIDE; CARBON NANOTUBES; BIOSENSOR; LUMINOL; ELECTROCHEMILUMINESCENCE; SYSTEM; NANOPARTICLES; ELECTRODE;
D O I
10.1016/j.ab.2013.01.022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and sensitive electrogenerated chemiluminescence (ECL) cholesterol biosensor was prepared based on cerium oxide-graphene (CeO2-graphene) composites as an efficient matrix. CeO2-graphene composites were prepared by depositing CeO2 onto graphene and were characterized by scanning electron microscopy. The experimental results demonstrated that CeO2-graphene could catalyze the ECL of a luminol-H2O2 (hydrogen peroxide) system to amplify the luminol ECL signal greatly. In addition, the use of CeO2-graphene provided a better biocompatible microenvironment for the immobilized enzyme, resulting in excellent stability and a long lifetime of the ECL biosensor. The surface assembly process, ECL behaviors, and electrochemistry of the biosensor were investigated in detail. The quantity of cholesterol was in the linear range from 12 mu M to 7.2 mM with a detection limit of 4.0 mu M (signal/noise = 3). In addition, the biosensor exhibited outstanding reproducibility, long-term stability, and selectivity. Moreover, this cholesterol biosensor offers an alternative analytical method with low cost and high speed. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 25 条
[1]   Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane [J].
Brahim, S ;
Narinesingh, D ;
Guiseppi-Elie, A .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :27-36
[2]   Multichannel electrochemiluminescence of luminol in neutral and alkaline aqueous solutions on a gold nanoparticle self-assembled electrode [J].
Cui, H ;
Xu, Y ;
Zhang, ZF .
ANALYTICAL CHEMISTRY, 2004, 76 (14) :4002-4010
[3]   Chemiluminescence as a diagnostic tool. A review [J].
Dodeigne, C ;
Thunus, L ;
Lejeune, R .
TALANTA, 2000, 51 (03) :415-439
[4]   Polypyrrole nanotube array sensor for enhanced adsorption of glucose oxidase in glucose biosensors [J].
Ekanayake, E. M. I. Mala ;
Preethichandra, D. M. G. ;
Kaneto, Keiichi .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (01) :107-113
[5]   Development of a stable cholesterol biosensor based on multi-walled carbon nanotubes-gold nanoparticles composite covered with a layer of chitosan-room-temperature ionic liquid network [J].
Gopalan, Anantha Iyengar ;
Lee, Kwang-Pill ;
Ragupathy, Dhanusuraman .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) :2211-2217
[6]   Ag nanoparticle-catalyzed chemiluminescent reaction between luminol and hydrogen peroxide [J].
Guo, Ji-Zhao ;
Cui, Hua ;
Zhou, Wei ;
Wang, Wei .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2008, 193 (2-3) :89-96
[7]   Chemiluminescence Reactions of a Luminol System Catalyzed by ZnO Nanoparticles [J].
Li, Shi-Feng ;
Zhang, Xin-Ming ;
Du, Wan-Xin ;
Ni, Yong-Hong ;
Wei, Xian-Wen .
JOURNAL OF PHYSICAL CHEMISTRY C, 2009, 113 (03) :1046-1051
[8]   Potassium-doped carbon nanotubes toward the direct electrochemistry of cholesterol oxidase and its application in highly sensitive cholesterol biosensor [J].
Li, Xiao-Rong ;
Xu, Jing-Juan ;
Chen, Hong-Yuan .
ELECTROCHIMICA ACTA, 2011, 56 (25) :9378-9385
[9]   Enhanced chemiluminescence detection of thrombin based on cerium oxide nanoparticles [J].
Li, Xuemei ;
Sun, Li ;
Ge, Anqing ;
Guo, Yingshu .
CHEMICAL COMMUNICATIONS, 2011, 47 (03) :947-949
[10]   Electrogenerated chemiluminescence aptamer-based biosensor for the determination of cocaine [J].
Li, Yan ;
Qi, Honglan ;
Peng, Yage ;
Yang, Jia ;
Zhang, Chengxiao .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (10) :2571-2575