Conductive and viscous sub-layers on forced convection and mechanism of critical heat flux during flow boiling of subcooled water in a circular tube at high liquid Reynolds number

被引:3
作者
Hata, K. [1 ]
Liu, Q. S. [1 ]
Masuzaki, S. [2 ]
机构
[1] Kobe Univ, Grad Sch Maritime Sci, Higashinada Ku, 5-1-1 Fukaeminami, Kobe, Hyogo 6580022, Japan
[2] Natl Inst Fus Sci, 322-6 Oroshi Cho, Toki, Gifu 5095292, Japan
关键词
PREDICTION; MODEL;
D O I
10.1007/s00231-018-2458-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
The turbulent heat transfer, the subcooled boiling heat transfer and the steady state CHF for a Pt-circular test tube of a 3mm inner diameter and a 100mm heated length are measured with a wide range of inlet subcooling and flow velocity at high liquid Reynolds number, i.e. Re-d=3.01x10(4) to 1.43x10(5). The inner surface temperature of the Pt-circular test tube calculated by the steady one-dimensional heat conduction equation is compared with the values derived from authors' turbulent heat transfer correlation and with the numerical solutions of the RANS equations (Reynolds Averaged Navier-Stokes Simulation) of k-epsilon turbulence model for the flow velocities ranging from 4 to 21m/s. The thicknesses of conductive sub-layer from non-boiling regime to CHF are measured by numerically analyzing the heat transfers with conductive sub-layer on forced convection and with thinner one dissipated by the evaporation on nucleate boiling. The thicknesses of viscous sub-layer on forced convection are estimated from the thicknesses of the conductive sub-layer and Prandtl numbers of the surface temperature on the heated surface. Furthermore, the thicknesses of conductive sub-layer at the CHF point are extrapolated from the measured values at various flow velocities. The experimental values of the CHF are also compared with authors' widely and precisely predictable correlations of critical heat flux during flow boiling of subcooled water and the corresponding theoretical values of the liquid sub-layer dry-out models suggested by other researchers, respectively. The authors' correlations and other researchers' theoretical values can represent the subcooled boiling CHFs obtained in this study within the ranges of -13.27 to 6.76% difference and-32.51 to 13.16% one, respectively. A suggestion based on the experimental data as to what the dominant mechanism is for critical heat flux during flow boiling of subcooled water on a vertical circular tube is confirmed again at high liquid Reynolds number. The transitions to film boiling at the subcooled water flow boiling on the Pt test tube of d=3mm and L=100mm would occur due to the liquid sub-layer dry-out model at the steady-state CHF as well as those on the Pt test tube of d=3mm and L=66.5mm, but not due to the heterogeneous spontaneous nucleation and the hydro-dynamic instability.
引用
收藏
页码:175 / 195
页数:21
相关论文
共 37 条
[1]  
[Anonymous], 1988, TRANSPORT PHENOMENA
[2]  
[Anonymous], 2009, ANAL MODELING PHYS T
[3]  
Bergles A.E., 1964, J HEAT TRANSF, V86, P365
[4]   RATIONALIZATION OF EXISTING MECHANISTIC MODELS FOR THE PREDICTION OF WATER SUBCOOLED FLOW BOILING CRITICAL HEAT-FLUX [J].
CELATA, GP ;
CUMO, M ;
MARIANI, A ;
SIMONCINI, M ;
ZUMMO, G .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 :347-360
[5]  
Favre-Marinet M., 2009, Convective Heat Transfer
[6]  
Ghiaasiaan SM, 2008, TWO-PHASE FLOW, BOILING AND CONDENSATION: IN CONVENTIONAL AND MINIATURE SYSTEMS, P38
[7]   Ultra-high critical heat flux (CHF) for subcooled water flow boiling - II: High-CHF database and design equations [J].
Hall, DD ;
Mudawar, I .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (08) :1429-1456
[8]   Conductive sublayer of turbulent heat transfer for heating of water in a circular tube [J].
Hata, K. ;
Fukuda, K. ;
Masuzaki, S. .
HEAT AND MASS TRANSFER, 2017, 53 (08) :2559-2576
[9]   Critical heat fluxes of subcooled water flow boiling against inlet subcooling in short vertical tube [J].
Hata, K ;
Komori, H ;
Shiotsu, M ;
Noda, N .
JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2004, 47 (02) :306-315
[10]   Critical heat fluxes of subcooled water flow boiling against outlet subcooling in short vertical tube [J].
Hata, K ;
Shiotsu, M ;
Noda, N .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2004, 126 (03) :312-320