Flexural strengths, failure load, and hardness of glass-ceramics for dental applications

被引:8
|
作者
Alghazzawi, Tariq F. [1 ,2 ,3 ]
机构
[1] Taibah Univ, Dept Substitut Dent Sci, Madina, Saudi Arabia
[2] Univ Alabama Birmingham, Dept Mat Sci & Engn, Birmingham, AL USA
[3] POB 51209, Riyadh 11543, Saudi Arabia
关键词
MECHANICAL-PROPERTIES; FRACTURE-RESISTANCE; CROWNS;
D O I
10.1016/j.prosdent.2022.05.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Glass-ceramics are often selected for use in dental restorations based upon advertised flexural strengths obtained from standardized tests on prefabricated specimens (bars and disks); these may not accurately reflect their performance in dental applications. Purpose. The purpose of this in vitro study was to determine and compare 4-point flexural strength, biaxial flexural strength, hardness, and crown failure loads for 3 commercially available glass-ceramics. Material and methods. Specimens were pressed and prepared from 3 brands of glass-ceramics: Celtra (CEL), IPS e.max (EMA), and Lisi (LIS). Rectangular bars, circular disks, and fully contoured crowns were created (n=15 specimens per glass-ceramic, 45 specimens per geometry, totaling 135 specimens). Disks were tested for biaxial flexural strength by using a piston-on-3-ball (POB) test, while bars were tested for 4-point flexural strength by using 4-point bending (4PB) and Vickers hardness (VH) tests. Crown failure loads were assessed in "crunch-the-crown " (CTC) tests. The results were analyzed by using general linear modeling, the Pearson correlation coefficient, and Weibull analysis. Results. The general linear modeling revealed significant differences (P <.05) in the failure load for crown specimens (EMA > LIS > CEL), the 4-point flexural strength (EMA > LIS > CEL), and the biaxial flexural strength (EMA > LIS=CEL). The disk specimens had higher flexural strengths than the bar specimens for CEL and EMA materials. LIS had a higher Weibull modulus than EMA and CEL for bar and crown specimens. CEL had a higher Weibull modulus than LIS and EMA for disk specimens. There was no correlation among the VH (R-2=0.86 and P=.24), biaxial flexural strength (R-2=0.84 and P=.26), and crown failure load. However, there was a high correlation between the failure load (crown specimens) and 4-point flexural strength (bar specimens) (R2=0.99 and P=.03). Conclusions. The 4-point flexural strength correlated significantly with crown failure load.
引用
收藏
页码:512.e1 / 512.e9
页数:9
相关论文
共 50 条
  • [21] Effect of sintering parameters on phase evolution and strength of dental lithium silicate glass-ceramics
    Lohbauer, Ulrich
    Belli, Renan
    Alonso, Alexandre Abdalla
    Goetz-Neunhoeffer, Friedlinde
    Hurle, Katrin
    DENTAL MATERIALS, 2019, 35 (10) : 1360 - 1369
  • [22] Surface Characterization and Optical Properties of Reinforced Dental Glass-Ceramics Related to Artificial Aging
    Porojan, Liliana
    Vasiliu, Roxana-Diana
    Birdeanu, Mihaela-Ionela
    Porojan, Sorin-Daniel
    MOLECULES, 2020, 25 (15):
  • [23] Mechanical Properties and Porosity of Dental Glass-Ceramics Hot-Pressed at Different Temperatures
    Gonzaga, Carla Castiglia
    Cesar, Paulo Francisco
    Okada, Cristina Yuri
    Fredericci, Catia
    Beneduce Neto, Flavio
    Yoshimura, Humberto Naoyuki
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2008, 11 (03): : 301 - 306
  • [24] A Comparison of Failure Loads for Polycrystalline Zirconia Ceramics with Varying Amounts of Yttria, Glass-Ceramics and Polymers in Two Different Test Conditions
    Alghazzawi, Tariq F.
    POLYMERS, 2023, 15 (23)
  • [25] The effect of ZrO2 and TiO2 on solubility and strength of apatite-mullite glass-ceramics for dental applications
    Fathi, Hawa M.
    Miller, Cheryl
    Stokes, Christopher
    Johnson, Anthony
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2014, 25 (03) : 583 - 594
  • [26] Bioactive Glasses and Glass-Ceramics for Healthcare Applications in Bone Regeneration and Tissue Engineering
    Fernandes, Hugo R.
    Gaddam, Anuraag
    Rebelo, Avito
    Brazete, Daniela
    Stan, George E.
    Ferreira, Jose M. F.
    MATERIALS, 2018, 11 (12)
  • [27] Design, selection and characterization of novel glasses and glass-ceramics for use in prosthetic applications
    Baino, Francesco
    Marshall, Martyn
    Kirk, Nicholas
    Vitale-Brovarone, Chiara
    CERAMICS INTERNATIONAL, 2016, 42 (01) : 1482 - 1491
  • [28] Relation of Crown Failure Load to Flexural Strength for Three Contemporary Dental Polymers
    Alghazzawi, Tariq F.
    POLYMERS, 2023, 15 (21)
  • [29] Influence of particle size on sinterability, crystallisation kinetics and flexural strength of wollastonite glass-ceramics from waste glass and fly ash
    Lu, Jinshan
    Lu, Zhangyang
    Peng, Changhao
    Li, Xibao
    Jiang, Hongliu
    MATERIALS CHEMISTRY AND PHYSICS, 2014, 148 (1-2) : 449 - 456
  • [30] Magnesium-containing bioactive polycrystalline silicate-based ceramics and glass-ceramics for biomedical applications
    Diba, Mani
    Goudouri, Ourania-Menti
    Tapia, Felipe
    Boccaccini, Aldo R.
    CURRENT OPINION IN SOLID STATE & MATERIALS SCIENCE, 2014, 18 (03) : 147 - 167