Numerical design and experimental analysis of cell-based sensors

被引:0
作者
Cai, Hua [1 ]
Qin, Lifeng [1 ]
Liu, Qingjun [1 ]
Xu, Ying [1 ]
Li, Rong [1 ]
Wang, Ping [1 ]
机构
[1] Zhejiang Univ, Dept Biomed Engn, Key Lab Biomed Engn Educ Minist, Biosensor Natl Special Lab, Hangzhou 310027, Peoples R China
来源
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7 | 2005年
关键词
cell-based sensor; biosensors; numerical analysis; modeling of sensors;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel numerical design of experimental analysis of cell-based sensors was introduced in the paper. In order to increase the signals to noise ratio and improve the performance of the chips, we analyzed cell-based sensors numerically and experimentally. Since the action potential which is about dozens of milliseconds changes quickly, we demonstrated an improved equivalent circuit model. Based on modeling of the interface between neuron and sensor, we predicted the experimental results. Furthermore, the experiment results indicate that the designed cell-based sensors can detect the extracellular AP, which meets the numerical consequence quite well.
引用
收藏
页码:1051 / 1054
页数:4
相关论文
共 11 条
  • [1] Fromherz P, 2002, CHEMPHYSCHEM, V3, P276, DOI 10.1002/1439-7641(20020315)3:3<276::AID-CPHC276>3.0.CO
  • [2] 2-A
  • [3] Investigation on light-addressable potentiometric sensor as a possible cell-semiconductor hybrid
    Ismail, ABM
    Yoshinobu, T
    Iwasaki, H
    Sugihara, H
    Yukimasa, T
    Hirata, I
    Iwata, H
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (12) : 1509 - 1514
  • [4] LIGHT-ADDRESSABLE CHEMICAL SENSORS - MODELING AND COMPUTER-SIMULATIONS
    MASSOBRIO, G
    MARTINOIA, S
    GRATTAROLA, M
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) : 484 - 487
  • [5] COMPUTER-SIMULATION AND OPTIMIZATION OF A LIGHT ADDRESSABLE POTENTIOMETRIC SENSOR
    SARTORE, M
    ADAMI, M
    NICOLINI, C
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (01) : 57 - 64
  • [6] Extracellular measurements of averaged ionic currents with the light-addressable potentiometric sensor (LAPS)
    Stein, B
    George, M
    Gaub, HE
    Parak, WJ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2004, 98 (2-3) : 299 - 304
  • [7] Cell-based biosensors and its application in biomedicine
    Wang, P
    Xu, GX
    Qin, LF
    Xu, Y
    Li, Y
    Li, R
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) : 576 - 584
  • [8] A novel microphysiometer based on MLAPS for drugs screening
    Wu, YC
    Wang, P
    Ye, XS
    Zhang, QT
    Li, R
    Yan, WM
    Zheng, XX
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (4-5) : 277 - 286
  • [9] Wu YC, 2001, SENSOR ACTUAT B-CHEM, V80, P215, DOI 10.1016/S0925-4005(01)00891-7
  • [10] Cell-based biosensors based on light-addressable potentiometric sensors for single cell monitoring
    Xu, GX
    Ye, XS
    Qin, LF
    Xu, Y
    Li, Y
    Li, R
    Wang, P
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (09) : 1757 - 1763