Transcatheter Closure of Intracristal Ventricular Septal Defect With Mild Aortic Cusp Prolapse Using Zero Eccentricity Ventricular Septal Defect Occluder

被引:26
作者
Chen, Feng [1 ]
Li, Pan [1 ]
Liu, Suxuan [1 ]
Du, He [1 ]
Zhang, Bili [1 ]
Jin, Xiucai [2 ]
Zheng, Xing [1 ]
Wu, Hong [1 ]
Chen, Shaoping [1 ]
Han, Lin [3 ]
Qin, Yongwen [1 ]
Zhao, Xianxian [1 ]
机构
[1] Second Mil Med Univ, Changhai Hosp, Dept Cardiol, Shanghai 200433, Peoples R China
[2] Second Mil Med Univ, Changhai Hosp, Dept Echocardiog, Shanghai 200433, Peoples R China
[3] Second Mil Med Univ, Changhai Hosp, Dept Cardiothorac Surg, Shanghai 200433, Peoples R China
关键词
Cardiac catheterization/intervention; Congenital; Coronary cusp prolapse; Heart defects; Intracristal ventricular septal defect; VALVE PROLAPSE; SURGICAL CLOSURE; NATURAL-HISTORY; DEVICE CLOSURE; REGURGITATION; EXPERIENCE; OUTCOMES;
D O I
10.1253/circj.CJ-15-0301
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transcatheter closure is a well-established therapy for patients with perimembranous ventricular septal defects (VSDs), but with limited experience in intracristal VSDs (IVSDs) with aortic cusp prolapse (ACP). Methods and Results: From 2012 to 2014, we reviewed 38 patients with IVSDs complicated with mild ACP who underwent device closure, and, in light of the findings, assessed the effect of transcatheter intervention on preoperative mild ACP. The zero eccentric VSD occluder was chosen for closure (Shanghai Shape Memory Alloy Ltd, Shanghai, China). The mean defect was 4.8 +/- 1.6 mm (range, 2-8) as measured by transthoracic echocardiography and the mean device size was 10.1 +/- 2.1 mm (range, 4-14). Placement of the device was successful in 35 patients (92.1%). In the remaining 3 patients (7.9%), major complications occurred and they were converted to surgical intervention: severe aortic regurgitation (AR) in 2 patients and occluder dislodgement in 1 patient. During the follow-up (median 14.2 months; range, 3-24), no deaths, residual shunt, late-onset AR, heart block, or device failure occurred. Conclusions: The mid-term prognostic results of high success rate and low complications rate in this study are inspiring. Transcatheter closure of IVSD with mild ACP can be performed safely and effectively as an alternative to surgery in selected patients.
引用
收藏
页码:2162 / 2168
页数:7
相关论文
共 28 条
[11]  
Jacobs J P, 2000, Ann Thorac Surg, V69, pS25
[12]  
Jian-Jun Ge, 2006, Heart Lung Circ, V15, P168, DOI 10.1016/j.hlc.2005.10.006
[13]   Surgical strategy for doubly committed subarterial ventricular septal defect with aortic cusp prolapse [J].
Komai, H ;
Naito, Y ;
Fujiwara, K ;
Noguchi, Y ;
Nishimura, Y ;
Uemura, S .
ANNALS OF THORACIC SURGERY, 1997, 64 (04) :1146-1149
[14]   Conduction Abnormality and Arrhythmia After Transcatheter Closure of Atrial Septal Defect [J].
Komar, Monika ;
Przewlocki, Tadeusz ;
Olszowska, Maria ;
Sobien, Bartosz ;
Stepniewski, Jakub ;
Podolec, Jakub ;
Mleczko, Szymon ;
Tomkiewicz-Pajak, Lidia ;
Zmudka, Krzysztof ;
Podolec, Piotr .
CIRCULATION JOURNAL, 2014, 78 (10) :2415-2421
[15]   Intraoperative TEE assessment of ventricular septal defect with aortic regurgitation [J].
Leung, MP ;
Chau, KT ;
Chiu, C ;
Yung, TC ;
Mok, CK .
ANNALS OF THORACIC SURGERY, 1996, 61 (03) :854-860
[16]   Arrhythmias after transcatheter closure of perimembranous ventricular septal defects with a modified double-disk occluder: early and long-term results [J].
Li, Pan ;
Zhao, Xian-xian ;
Zheng, Xing ;
Qin, Yong-wen .
HEART AND VESSELS, 2012, 27 (04) :405-410
[17]   Analysis of indications for surgical closure of subarterial ventricular septal defect without associated aortic cusp prolapse and aortic regurgitation [J].
Lun, KS ;
Li, H ;
Leung, MP ;
Chau, AKT ;
Yung, TC ;
Chiu, CSW ;
Cheung, YF .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (11) :1266-1270
[18]   NATURAL-HISTORY OF SUBARTERIAL INFUNDIBULAR VENTRICULAR SEPTAL-DEFECT [J].
MOMMA, K ;
TOYAMA, K ;
TAKAO, A ;
ANDO, M ;
NAKAZAWA, M ;
HIROSAWA, K ;
IMAI, Y .
AMERICAN HEART JOURNAL, 1984, 108 (05) :1312-1317
[19]  
MORI K, 1995, EUR J PEDIATR, V154, P176, DOI 10.1007/s004310050270
[20]   Comparison Between the New Gore Septal and Amplatzer Devices For Transcatheter Closure of Patent Foramen Ovale - Short- and Mid-Term Clinical and Echocardiographic Outcomes [J].
Musto, Carmine ;
Cifarelli, Alberta ;
Fiorilli, Rosario ;
De Felice, Francesco ;
Parma, Antonio ;
Nazzaro, Marco Stefano ;
Guerra, Elena ;
Fiorilli, Francesca ;
Violini, Roberto .
CIRCULATION JOURNAL, 2013, 77 (12) :2922-2927