B-type Natruiretic Peptide Levels Stratify the Risk for Arrhythmia Among Implantable Cardioverter Defibrillator Patients

被引:11
作者
Galante, Ori [2 ]
Amit, Guy [1 ]
Zahger, Doron [2 ]
Wagshal, Abraham [2 ]
Ilia, Reuben [2 ]
Katz, Amos [3 ]
机构
[1] Case Western Reserve Univ, Heart & Vasc Res Ctr, Cleveland, OH 44109 USA
[2] Ben Gurion Univ Negev, Fac Hlth Sci, Soroka Univ, Dept Cardiol,Med Ctr, Beer Sheva, Israel
[3] Ben Gurion Univ Negev, Fac Hlth Sci, Barzilai Med Ctr, Dept Cardiol, Ashqelon, Israel
关键词
B-type natriuretic peptide; sudden death; ventricular tachycardia; ventricular fibrillation; implantable cardioverter defibrillator;
D O I
10.1002/clc.20336
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We sought to study the association between brain natriuretic peptide (BNP) levels and the occurrence of ventricular arrhythmias in patients with left ventricular dysfunction (LVD) and an implantable cardioverter defibrillator (ICD). Methods: This was a prospective study of consecutive, stable, ambulatory patients with moderate and severe ischemic LVD and an ICD. A plasma BNP level was obtained at recruitment. Patients were evaluated every 3-6 mo for a minimum of 1 y. The primary end point was the occurrence of malignant ventricular arrhythmia or sudden cardiac death (SCD). Results: The cohort consisted Of 94 subjects (6 women) with a mean +/- standard deviation (SD) age of 69 +/- 10 y. The ICD implantation indication was primary and secondary prevention of SCD in 49% and 51% of subjects, respectively. A primary end point occurred in 27 patients (29%), and was more frequent in symptomatic heart failure patients and those implanted for secondary prevention of SCD. The median BNP level was significantly higher among patients who experienced an end point (191 pg/ml versus 142 pg/ml, P = 0.03). After controlling for New York Heart Association heart failure class and ICD implantation indication, the odds ratio (OR) for experiencing an adverse outcome among the upper BNP quartile versus all others was 3.5 (95% confidence interval [Cl]: 1.2-10.2). Among patients implanted for primary prevention of SCD, none of the patients in the lower BNP quartile (BNP < 91 pg/ml) experienced an adverse outcome. Conclusions: These results suggest that abnormally high BNP levels not only predict cardiac death, but also arrhythmic death in this patient population, and a low BNP level can serve to identify low risk patients.
引用
收藏
页码:586 / 589
页数:4
相关论文
共 12 条
[1]   B-type natriuretic peptide predicts sudden death in patients with chronic heart failure [J].
Berger, R ;
Huelsman, M ;
Strecker, K ;
Bojic, A ;
Moser, P ;
Stanek, B ;
Pacher, R .
CIRCULATION, 2002, 105 (20) :2392-2397
[2]  
BLANGY H, EUROPACE
[3]  
Gold MR, 2000, PACE, V23, P1981
[4]   Effects of mechanosensitive ion channels on ventricular electrophysiology: experimental and theoretical models [J].
Kohl, P ;
Bollensdorff, C ;
Garny, A .
EXPERIMENTAL PHYSIOLOGY, 2006, 91 (02) :307-321
[5]   Amino-terminal pro-brain natriuretic peptide predicts ventricular arrhythmogenesis in patients with ischemic cardiomyopathy and implantable cardioverter-defibrillators [J].
Manios, EG ;
Kallergis, EM ;
Kanoupakis, EM ;
Mavrakis, HE ;
Kambouraki, DC ;
Arfanakis, DA ;
Vardas, PE .
CHEST, 2005, 128 (04) :2604-2610
[6]  
McAnulty J, 1997, NEW ENGL J MED, V337, P1576
[7]   Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction [J].
Moss, AJ ;
Zareba, W ;
Hall, WJ ;
Klein, H ;
Wilber, DJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Brown, MW ;
Andrews, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) :877-883
[8]   Cost-effectiveness of implantable cardioverter-defibrillators [J].
Sanders, GD ;
Hlatky, MA ;
Owens, DK .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (14) :1471-1480
[9]   Natriuretic peptides as predictors of non-sudden and sudden cardiac death after acute myocardial infarction in the beta-blocking era [J].
Tapanainen, JM ;
Lindgren, KS ;
Mäkikallio, TH ;
Vuolteenaho, O ;
Leppäluoto, J ;
Huikuri, HV .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :757-763
[10]   Preimplantation B-type natriuretic peptide concentration is an independent predictor of future appropriate implantable defibrillator therapies [J].
Verma, A ;
Kilicaslan, F ;
Martin, DO ;
Minor, S ;
Starling, R ;
Marrouche, NF ;
Almahammed, S ;
Wazni, OM ;
Duggal, S ;
Zuzek, R ;
Yamaji, H ;
Cummings, J ;
Chung, MK ;
Tchou, PJ ;
Natale, A .
HEART, 2006, 92 (02) :190-195