Bone Conduction Trial Device to Eliminate the Effect of Transcranial Attenuation: A Prospective Observational Study in Single-Sided Deaf Subjects

被引:2
作者
Claes, Annes [1 ,2 ]
Bouzegta, Rajae [1 ]
Van Rompaey, Vincent [1 ,2 ]
Vanderveken, Olivier [1 ,2 ]
Van de Heyning, Paul [1 ,2 ]
Mertens, Griet [1 ,2 ]
机构
[1] Antwerp Univ Hosp, Dept Otorhinolaryngol Head & Neck Surg, Antwerp, Belgium
[2] Univ Antwerp, Fac Med & Hlth Sci, Expt Lab Translat Neurosci & Dentootolaryngol, Antwerp, Belgium
关键词
Bone conduction; Contact mini; Hearing aid; Transcranial attenuation; Single-sided deafness; Unilateral hearing loss; Hearing performance; UNILATERAL DEAFNESS; HEARING-LOSS; ADULTS;
D O I
10.1159/000503844
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives:The contact mini(TM) (CM) is a nonimplantable, digital bone conduction device (BCD) consisting of 2 isolated units: an electronic housing, including the microphone, and a vibrator housing. The study investigated whether the CM can be used as an alternative test device for a BCD trial in single-sided deaf (SSD) adults with the microphone placed at the SSD ear and the vibrator at the normal-hearing (NH) ear (i.e., cross position).Methods:Twenty SSD adults (mean age: 50 [+/- 13.2] years) participated in a 2-week BCD trial with the CM on the headband in cross position. Prior to the trial, the subjects performed adaptive speech-in-noise tests in an unaided condition. After the trial, speech-in-noise tests were performed with the CM in cross position (CMcross) and ipsilateral position, i.e., both units at the SSD ear (CMipsi). Five different speech-in-noise configurations were used (S0N0; S0NNH; S0NSSD; S0 degrees NNH+SSD; and SSSDNNH). Speech reception thresholds (SRT) were analyzed comparing the unaided, the CMcross condition, and the CMipsi condition.Results:Friedman's test revealed no significant differences in SRTs between the CMcross, CMipsi, and the unaided condition for the S0N0, S0NNH, S0NSSD, and S0 degrees NNH+SSD configuration. However, in the SSSDNNH configuration, a significant effect was found (p< 0.001). Wilcoxon pairwise comparisons with Bonferroni correction indicated that SRTs in the CMcross condition were significantly lower (i.e., better speech understanding) than those in the unaided (p< 0.001) and the CMipsi condition (p< 0.05).Conclusion:The CM may be a good alternative for patients with SSD, resulting in significantly better speech recognition when noise is presented to the NH ear and speech to the SSD ear. As the speech recognition results are better in the cross than the ipsilateral position, the CMcross might help to overcome the negative effect of transcranial attenuation during BCD trials.
引用
收藏
页码:231 / 236
页数:6
相关论文
共 18 条
[1]  
Arndt S, 2017, HNO, V65, P98, DOI 10.1007/s00106-016-0297-5
[2]   Comparison of Pseudobinaural Hearing to Real Binaural Hearing Rehabilitation After Cochlear Implantation in Patients With Unilateral Deafness and Tinnitus [J].
Arndt, Susan ;
Aschendorff, Antje ;
Laszig, Roland ;
Beck, Rainer ;
Schild, Christian ;
Kroeger, Stefanie ;
Ihorst, Gabriele ;
Wesarg, Thomas .
OTOLOGY & NEUROTOLOGY, 2011, 32 (01) :39-47
[3]   Importance of Binaural Hearing [J].
Avan, Paul ;
Giraudet, Fabrice ;
Bueki, Bela .
AUDIOLOGY AND NEURO-OTOLOGY, 2015, 20 :3-6
[4]  
BHM-Tech Produktionsgesellschaft mbH, CONT MIN COND HEAR S
[5]  
Briggs R, 2015, OTOL NEUROTOL, V36, P834, DOI 10.1097/MAO.0000000000000712
[6]   Audiological and clinical outcomes of a transcutaneous bone conduction hearing implant: Six-month results from a multicentre study [J].
den Besten, Christine A. ;
Monksfield, Peter ;
Bosman, Arjan ;
Skarzynski, Piotr H. ;
Green, Kevin ;
Runge, Christina ;
Wigren, Stina ;
Blechert, Johan I. ;
Flynn, Mark C. ;
Mylanus, Emmanuel A. M. ;
Hol, Myrthe K. S. .
CLINICAL OTOLARYNGOLOGY, 2019, 44 (02) :144-157
[7]   Speech Understanding and Sound Localization with a New Nonimplantable Wearing Option for Baha [J].
Gawliczek, Tom ;
Wimmer, Wilhelm ;
Munzinger, Fabio ;
Caversaccio, Marco ;
Kompis, Martin .
BIOMED RESEARCH INTERNATIONAL, 2018, 2018
[8]   Hearing Instruments for Unilateral Severe-to-Profound Sensorineural Hearing Loss in Adults: A Systematic Review and Meta-Analysis [J].
Kitterick, Padraig Thomas ;
Smith, Sandra Nelson ;
Lucas, Laura .
EAR AND HEARING, 2016, 37 (05) :495-507
[9]  
Kompis M, 2011, ADV OTO-RHINO-LARYNG, V71, P103, DOI 10.1159/000323591
[10]   Contralateral Routing of Signal Hearing Aid versus Transcutaneous Bone Conduction in Single-Sided Deafness [J].
Leterme, Gaelle ;
Bernardeschi, Daniele ;
Bensemman, Anissa ;
Coudert, Cyrille ;
Portal, Jean-Jacques ;
Ferrary, Evelyne ;
Sterkers, Olivier ;
Vicaut, Eric ;
Frachet, Bruno ;
Grayeli, Alexis Bozorg .
AUDIOLOGY AND NEURO-OTOLOGY, 2015, 20 (04) :251-260