Visual acuity and image quality in 5 diffractive intraocular lenses

被引:20
作者
Cardona, Genis [1 ]
Vega, Fidel [1 ]
Gil, Miguel A. [2 ]
Varon, Consuelo [1 ]
Buil, Jose A. [2 ]
Millan, Maria S. [1 ]
机构
[1] Polytech Univ Catalonia Barcelona Tech, Dept Opt & Optometry, Appl Opt & Image Proc Grp, Terrassa, Spain
[2] Autonomous Univ Barcelona, Santa Creu & St Pau Hosp, Dept Ophthalmol, Barcelona, Spain
关键词
Diffractive optics; Intraocular lens; Multifocal; Objective image quality; Visual acuity; MODULATION TRANSFER-FUNCTION; OPTICAL BENCH PERFORMANCE; CATARACT; OUTCOMES; RESTOR; REZOOM;
D O I
10.5301/ejo.5000994
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare objective image quality at distant, intermediate, and near foci with the corresponding visual acuity (VA) in patients symmetrically implanted with 5 different diffractive multifocal intraocular lenses (IOLs) (ReSTOR SV25T0, Tecnis ZKB00, Tecnis ZLB00, AT LISA 809, and AT LISA Tri 839MP) and a monofocal lens (Tecnis ZA9003) 3 months after cataract intervention. Methods: Objective image quality, measured as the area under the modulation transfer function curve (AMTF), was tested in vitro in an eye model. In addition, corrected distance visual acuity and distance-corrected intermediate and near visual acuities (DCIVA and DCNVA) were assessed in a group of 79 patients, randomly implanted with one of the lenses. Results: Image quality and VA at the distant focus was good for all lens designs, but was similarly compromised at the intermediate focus, where the best DCIVA corresponded to the low add ZKB00. At the near focus, the monofocal lens and the distance dominant SV25T0 had the worst AMTF values, with the ZLB00 presenting the best DCNVA. The relationship between AMTF and VA was found not to be linear, with VA being similarly good for AMTF values over a certain threshold. Conclusions: Visual acuity of pseudophakic patients reflected the optical quality of the specific IOL design within a certain range of measurements, beyond which maximum VA is limited by other ocular, optical, and neuropsychophysical factors.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 26 条
[1]  
[Anonymous], 2014, International Organization for Standerdization ISO 11979-2:2014 Ophthalmic implants
[2]   Image quality with multifocal intraocular lenses and the effect of pupil size -: Comparison of refractive and hybrid refractive-diffractive designs [J].
Artigas, Jose M. ;
Menezo, Jose L. ;
Peris, Cristina ;
Felipe, Adelina ;
Diaz-Llopis, Manuel .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) :2111-2117
[3]   Multifocal versus monofocal intraocular lenses after cataract extraction [J].
Calladine, Daniel ;
Evans, Jennifer R. ;
Shah, Sweata ;
Leyland, Martin .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (09)
[4]   Optical bench performance of AcrySof((R)) IQ ReSTOR (R), AT LISA((R)) tri, and FineVision((R)) intraocular lenses [J].
Carson, Daniel ;
Hill, Warren E. ;
Hong, Xin ;
Karakelle, Mutlu .
CLINICAL OPHTHALMOLOGY, 2014, 8 :2105-2113
[5]   Functional vision with bilateral ReZoom and ReSTOR intraocular lenses 6 months after cataract surgery [J].
Chiam, Patrick J. T. ;
Chan, Jin H. ;
Haider, Syed I. ;
Karia, Niral ;
Kasaby, Hosam ;
Aggarwal, Rajesh K. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) :2057-2061
[6]   Optical performance measurement and night driving simulation of ReSTOR, ReZoom, and Tecnis multifocal intraocular lenses in a model eye [J].
Choi, Junoh ;
Schwiegerling, Jim .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) :218-222
[7]   Working-Age Cataract Patients: Visual Results, Reading Performance, and Quality of Life with Three Diffractive Multifocal Intraocular Lenses [J].
Cillino, Giovanni ;
Casuccio, Alessandra ;
Pasti, Mattia ;
Bono, Valeria ;
Mencucci, Rita ;
Cillino, Salvatore .
OPHTHALMOLOGY, 2014, 121 (01) :34-44
[8]   Multifocal intraocular lenses in cataract surgery: Literature review of benefits and side effects [J].
de Vries, Niels E. ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (02) :268-278
[9]   Correlation between optics quality of multifocal intraocular lenses and visual acuity Tolerance to modulation transfer function decay [J].
Felipe, Adelina ;
Pastor, Francisco ;
Artigas, Jose M. ;
Diez-Ajenjo, Amparo ;
Gene, Andres ;
Menezo, Jose L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) :557-562
[10]   Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench [J].
Gatinel, Damien ;
Houbrechts, Yvette .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (07) :1093-1099