Transcatheter aortic valves produce unphysiological flows which may contribute to thromboembolic events: An in-vitro study

被引:55
作者
Ducci, Andrea [1 ]
Pirisi, Francesco [1 ]
Tzamtzis, Spyridon [1 ]
Burriesci, Gaetano [1 ,2 ]
机构
[1] UCL, UCL Mech Engn, UCL Cardiovasc Engn Lab, London, England
[2] Fdn Ri MED, Bioengn Grp, Palermo, Italy
基金
英国惠康基金;
关键词
Transcatheter aortic valve implantation (TAVI); Blood stagnation; Particle Image Velocimetry (PIV); Thrombo-embolism; Valsalva sinus; PARTICLE IMAGE VELOCIMETRY; HIGH-RISK PATIENTS; HEART-VALVE; REPLACEMENT; IMPLANTATION; DYNAMICS; STENOSIS; SILENT; DOWNSTREAM; OUTCOMES;
D O I
10.1016/j.jbiomech.2016.10.050
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose: Transcatheter aortic valve implantation (TAVI) has been associated with large incidence of ischemic events, whose sources are still unclear. In fact, sub-acute complications cannot be directly related to the severity of the calcification in the host tissues, nor with catheter manipulation during the implant. A potential cause could be local flow perturbations introduced by the implantation approach, resulting in thrombo-embolic consequences. In particular, contrary to the surgical approach, TAVI preserves the presence of the native leaflets, which are expanded in the paravalvular space inside the Valsalva sinuses. The purpose of this study is to verify if this configuration can determine hemodynamic variations which may promote blood cell aggregation and thrombus formation. Methods: The study was performed in vitro, on idealized models of the patient anatomy before and after TAVI, reproducing a range of physiological operating conditions on a pulse duplicator. The fluid dynamics in the Valsalva sinuses was analyzed and characterized using phase resolved Particle Image Velocimetry. Results: Comparison of the flow downstream the valve clearly indicated major alterations in the fluid mechanics after TAVI, characterized by unphysiological conditions associated with extended stagnation zones at the base of the sinuses. Conclusion: The prolonged stasis observed in the Valsalva sinuses for the configuration modelling the presence of transcatheter aortic valves provides a fluid dynamic environment favourable for red blood cell aggregation and thrombus formation, which may justify some of the recently reported thromboembolic and ischemic events. This suggests the adoption of anticoagulation therapies following TAVI, and some caution in the patients' selection. (C) 2016 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:4080 / 4089
页数:10
相关论文
共 54 条
[1]   Dynamic particle image velocimetry study of the aortic flow field of contemporary mechanical bileaflet prostheses [J].
Akutsu, Toshinosuke ;
Saito, Jun ;
Imai, Ryota ;
Suzuki, Tomoyuki ;
Cao, Xiu Dong .
JOURNAL OF ARTIFICIAL ORGANS, 2008, 11 (02) :75-90
[2]   Magnetic resonance imaging evaluation of cerebral embolization during percutaneous aortic valve implantation: comparison of transfemoral and trans-apical approaches using Edwards Sapiens valve [J].
Astarci, Parla ;
Glineur, David ;
Kefer, Joelle ;
D'Hoore, William ;
Renkin, Jean ;
Vanoverschelde, Jean-Louis ;
El Khoury, Gebrine ;
Grandin, Cecile .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (02) :475-479
[3]   Influence of Transcatheter Aortic Valve Replacement Strategy and Valve Design on Stroke After Transcatheter Aortic Valve Replacement [J].
Athappan, Ganesh ;
Gajulapalli, R. Dilip ;
Sengodan, Prasanna ;
Bhardwaj, Anju ;
Ellis, Stephen G. ;
Svensson, Lars ;
Tuzcu, Emin Murat ;
Kapadia, Samir R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (20) :2101-2110
[4]   Energy Loss Due to Paravalvular Leak With Transcatheter Aortic Valve Implantation [J].
Azadani, Ali N. ;
Jaussaud, Nicolas ;
Matthews, Peter B. ;
Ge, Liang ;
Guy, T. Sloane ;
Chuter, Timothy A. M. ;
Tseng, Elaine E. .
ANNALS OF THORACIC SURGERY, 2009, 88 (06) :1857-1863
[5]   Evaluation of Patients With Severe Symptomatic Aortic Stenosis Who Do Not Undergo Aortic Valve Replacement The Potential Role of Subjectively Overestimated Operative Risk [J].
Bach, David S. ;
Siao, Derrick ;
Girard, Steven E. ;
Duvernoy, Claire ;
McCallister, Benjamin D., Jr. ;
Gualano, Sarah K. .
CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2009, 2 (06) :533-539
[6]   Need for Permanent Pacemaker as a Complication of Transcatheter Aortic Valve Implantation and Surgical Aortic Valve Replacement in Elderly Patients With Severe Aortic Stenosis and Similar Baseline Electrocardiographic Findings [J].
Bagur, Rodrigo ;
Rodes-Cabau, Josep ;
Gurvitch, Ronen ;
Dumont, Eric ;
Velianou, James L. ;
Manazzoni, Juan ;
Toggweiler, Stefan ;
Cheung, Anson ;
Ye, Jian ;
Natarajan, Madhu K. ;
Bainey, Kevin R. ;
DeLarochelliere, Robert ;
Doyle, Daniel ;
Pibarot, Philippe ;
Voisine, Pierre ;
Cote, Melanie ;
Philippon, Francois ;
Webb, John G. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) :540-551
[7]  
Balducci A, 2004, EXP FLUIDS, V36, P204, DOI 10.1007/S00348-003-0744-4
[8]   Which way in? The Necessity of Multiple Approaches to Transcatheter Valve Therapy [J].
Bleiziffer, S. ;
Krane, M. ;
Deutsch, M. A. ;
Elhmidi, Y. ;
Piazza, N. ;
Voss, B. ;
Lange, R. .
CURRENT CARDIOLOGY REVIEWS, 2013, 9 (04) :268-273
[9]   Small aortic annulus: The hydrodynamic performances of 5 commercially available bileaflet mechanical valves [J].
Bottio, T ;
Caprili, L ;
Casarotto, D ;
Gerosa, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (03) :457-462
[10]   Experimental investigation of the steady flow downstream of the St. Jude bileaflet heart valve: A comparison between laser Doppler velocimetry and particle image velocimetry techniques [J].
Browne, P ;
Ramuzat, A ;
Saxena, R ;
Yoganathan, AP .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (01) :39-47