Bismuth-based porous screen-printed carbon electrode with enhanced sensitivity for trace heavy metal detection by stripping voltammetry

被引:72
作者
Chen, Chen [1 ,2 ]
Niu, Xiangheng [1 ,2 ]
Chai, Yan [1 ,2 ]
Zhao, Hongli [4 ]
Lan, Minbo [1 ,2 ,3 ]
机构
[1] E China Univ Sci & Technol, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] E China Univ Sci & Technol, Res Ctr Anal & Test, Shanghai 200237, Peoples R China
[3] E China Univ Sci & Technol, Minist Educ, Key Lab Ultrafine Mat, Shanghai 200237, Peoples R China
[4] E China Univ Sci & Technol, Inst Appl Chem, Shanghai 200237, Peoples R China
关键词
Porous screen-printed carbon electrode; Bismuth film; Stripping voltammetry; Lead(II); Cadmium(II); ANTIMONY FILM ELECTRODE; POWDER;
D O I
10.1016/j.snb.2012.12.109
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here we report a new disposable bismuth-coated porous screen-printed carbon electrode (Bi-P-SPCE) for trace heavy metal ions detection. The Bi-P-SPCE was fabricated by two processes: firstly, the porous screen-printed carbon electrode (P-SPCE) was prepared by combing a printing procedure of a graphite-based layer doped with CaCO3 powders with a subsequent dissolution of these powders; secondly, a Bi film layer was formed on the P-SPCE by in situ electrodepositing Bi(III) along with accumulating analytes. Due to the rough surface, large active area and low background noise of P-SPCE, the electrode exhibited significantly enhanced sensitivity, for lead(II) and cadmium(II) detection compared to screen-printed carbon electrode (SPCE) and glassy carbon electrode (GCE). With a preconcentration at -1.2 V (vs. Ag/AgCl) for 300 s, the detection limits obtained on the proposed Bi-P-SPCE are 0.03 mu g/L and 0.34 mu g/L (S/N = 3) for lead(II) and cadmium(II), respectively. This easy-to-prepare and low-cost electrode was also successfully applied to real water sample analysis. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:339 / 342
页数:4
相关论文
共 19 条
  • [1] Anodic Stripping Voltammetry Combined with Sequential Injection Analysis for Measurements of Trace Metal Ions with Bismuth- and Antimony Film Electrodes under Comparable Conditions
    Guzsvany, Valeria
    Nakajima, Hizuru
    Soh, Nobuaki
    Nakano, Koji
    Svancara, Ivan
    Vytras, Karel
    Bjelica, Luka
    Imato, Toshihiko
    [J]. ELECTROANALYSIS, 2011, 23 (07) : 1593 - 1601
  • [2] Antimony film electrode for electrochemical stripping analysis
    Hocevar, Samo B.
    Svancara, Ivan
    Ogorevc, Bozidar
    Vytras, Karel
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (22) : 8639 - 8643
  • [3] Novel electrode for electrochemical stripping analysis based on carbon paste modified with bismuth powder
    Hocevar, SB
    Svancara, I
    Vytras, K
    Ogorevc, B
    [J]. ELECTROCHIMICA ACTA, 2005, 51 (04) : 706 - 710
  • [4] A study on operational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry
    Hocevar, SB
    Ogorevc, B
    Wang, J
    Pihlar, B
    [J]. ELECTROANALYSIS, 2002, 14 (24) : 1707 - 1712
  • [5] Stripping analysis at bismuth-based electrodes
    Kokkinos, Christos
    Economou, Anastasios
    [J]. CURRENT ANALYTICAL CHEMISTRY, 2008, 4 (03) : 183 - 190
  • [6] Disposable lithographically fabricated bismuth microelectrode arrays for stripping voltammetric detection of trace metals
    Kokkinos, Christos
    Economou, Anastasios
    Raptis, Ioannis
    Speliotis, Thanassis
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (05) : 391 - 395
  • [7] Bismuth nano-powder electrode for trace analysis of heavy metals using anodic stripping voltammetry
    Lee, Gyoung-Ja
    Lee, Hi-Min
    Rhee, Chang-Kyu
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (10) : 2514 - 2518
  • [8] Square-wave voltammetric determination of thallium using surface modified thick-film graphite electrode with Bi nanopowder
    Lee, Gyroung-Ja
    Lee, Hi Min
    Uhm, Young Rang
    Lee, Min Ku
    Rhee, Chang-Kyu
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (12) : 1920 - 1923
  • [9] Economic bismuth-film microsensor for anodic stripping analysis of trace heavy metals using differential pulse voltammetry
    Legeai, S
    Soropogui, K
    Cretinon, M
    Vittori, O
    De Oliveira, AH
    Barbier, F
    Grenier-Loustalot, MF
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (05) : 839 - 847
  • [10] Simultaneous determination of ultratrace lead and cadmium by square wave stripping voltammetry with in situ depositing bismuth at Nafion-medical stone doped disposable electrode
    Li, Hongbo
    Li, Jing
    Yang, Zhanjun
    Xu, Qin
    Hou, Chuantao
    Peng, Jinyun
    Hu, Xiaoya
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2011, 191 (1-3) : 26 - 31