Bismuth-based porous screen-printed carbon electrode with enhanced sensitivity for trace heavy metal detection by stripping voltammetry

被引:74
作者
Chen, Chen [1 ,2 ]
Niu, Xiangheng [1 ,2 ]
Chai, Yan [1 ,2 ]
Zhao, Hongli [4 ]
Lan, Minbo [1 ,2 ,3 ]
机构
[1] E China Univ Sci & Technol, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] E China Univ Sci & Technol, Res Ctr Anal & Test, Shanghai 200237, Peoples R China
[3] E China Univ Sci & Technol, Minist Educ, Key Lab Ultrafine Mat, Shanghai 200237, Peoples R China
[4] E China Univ Sci & Technol, Inst Appl Chem, Shanghai 200237, Peoples R China
关键词
Porous screen-printed carbon electrode; Bismuth film; Stripping voltammetry; Lead(II); Cadmium(II); ANTIMONY FILM ELECTRODE; POWDER;
D O I
10.1016/j.snb.2012.12.109
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here we report a new disposable bismuth-coated porous screen-printed carbon electrode (Bi-P-SPCE) for trace heavy metal ions detection. The Bi-P-SPCE was fabricated by two processes: firstly, the porous screen-printed carbon electrode (P-SPCE) was prepared by combing a printing procedure of a graphite-based layer doped with CaCO3 powders with a subsequent dissolution of these powders; secondly, a Bi film layer was formed on the P-SPCE by in situ electrodepositing Bi(III) along with accumulating analytes. Due to the rough surface, large active area and low background noise of P-SPCE, the electrode exhibited significantly enhanced sensitivity, for lead(II) and cadmium(II) detection compared to screen-printed carbon electrode (SPCE) and glassy carbon electrode (GCE). With a preconcentration at -1.2 V (vs. Ag/AgCl) for 300 s, the detection limits obtained on the proposed Bi-P-SPCE are 0.03 mu g/L and 0.34 mu g/L (S/N = 3) for lead(II) and cadmium(II), respectively. This easy-to-prepare and low-cost electrode was also successfully applied to real water sample analysis. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:339 / 342
页数:4
相关论文
共 19 条
[1]   Anodic Stripping Voltammetry Combined with Sequential Injection Analysis for Measurements of Trace Metal Ions with Bismuth- and Antimony Film Electrodes under Comparable Conditions [J].
Guzsvany, Valeria ;
Nakajima, Hizuru ;
Soh, Nobuaki ;
Nakano, Koji ;
Svancara, Ivan ;
Vytras, Karel ;
Bjelica, Luka ;
Imato, Toshihiko .
ELECTROANALYSIS, 2011, 23 (07) :1593-1601
[2]   Antimony film electrode for electrochemical stripping analysis [J].
Hocevar, Samo B. ;
Svancara, Ivan ;
Ogorevc, Bozidar ;
Vytras, Karel .
ANALYTICAL CHEMISTRY, 2007, 79 (22) :8639-8643
[3]   Novel electrode for electrochemical stripping analysis based on carbon paste modified with bismuth powder [J].
Hocevar, SB ;
Svancara, I ;
Vytras, K ;
Ogorevc, B .
ELECTROCHIMICA ACTA, 2005, 51 (04) :706-710
[4]   A study on operational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry [J].
Hocevar, SB ;
Ogorevc, B ;
Wang, J ;
Pihlar, B .
ELECTROANALYSIS, 2002, 14 (24) :1707-1712
[5]   Stripping analysis at bismuth-based electrodes [J].
Kokkinos, Christos ;
Economou, Anastasios .
CURRENT ANALYTICAL CHEMISTRY, 2008, 4 (03) :183-190
[6]   Disposable lithographically fabricated bismuth microelectrode arrays for stripping voltammetric detection of trace metals [J].
Kokkinos, Christos ;
Economou, Anastasios ;
Raptis, Ioannis ;
Speliotis, Thanassis .
ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (05) :391-395
[7]   Bismuth nano-powder electrode for trace analysis of heavy metals using anodic stripping voltammetry [J].
Lee, Gyoung-Ja ;
Lee, Hi-Min ;
Rhee, Chang-Kyu .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (10) :2514-2518
[8]   Square-wave voltammetric determination of thallium using surface modified thick-film graphite electrode with Bi nanopowder [J].
Lee, Gyroung-Ja ;
Lee, Hi Min ;
Uhm, Young Rang ;
Lee, Min Ku ;
Rhee, Chang-Kyu .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (12) :1920-1923
[9]   Economic bismuth-film microsensor for anodic stripping analysis of trace heavy metals using differential pulse voltammetry [J].
Legeai, S ;
Soropogui, K ;
Cretinon, M ;
Vittori, O ;
De Oliveira, AH ;
Barbier, F ;
Grenier-Loustalot, MF .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (05) :839-847
[10]   Simultaneous determination of ultratrace lead and cadmium by square wave stripping voltammetry with in situ depositing bismuth at Nafion-medical stone doped disposable electrode [J].
Li, Hongbo ;
Li, Jing ;
Yang, Zhanjun ;
Xu, Qin ;
Hou, Chuantao ;
Peng, Jinyun ;
Hu, Xiaoya .
JOURNAL OF HAZARDOUS MATERIALS, 2011, 191 (1-3) :26-31