Low cost "laserless" FTIR spectrometer on the farm for real-time nitrous oxide soil emission measurements

被引:3
|
作者
Haugholt, Karl Henrik [1 ]
Lacolle, Matthieu [1 ]
O'Farrell, Marion [1 ]
Honne, Atle [1 ]
Bakke, Kari Anne Hestnes [1 ]
Lundon, Aina [2 ]
机构
[1] SINTEF ICT, N-0314 Oslo, Norway
[2] Bioforsk Norwegian Inst Agr & Environm Res, N-2849 Kapp, Norway
关键词
N2O; NO;
D O I
10.1364/AO.52.000B93
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A low-cost Fourier transform infrared (FTIR) instrument was developed where the traditional He-Ne reference laser was replaced by a low-cost linear encoder. An RMS sampling error of less than 20 nm was achieved by oversampling both the interferogram and the encoder signal and then resampling the interferogram using a correction table for the encoder. A gas calibration model was developed for the system, which was chosen to have a stroke length of 21 mm and, thereby, a resolution of 0.4 cm(-1) after apodization. The instrument was mounted on a vehicle and employed in an agricultural field test for measuring soil emissions, in particular nitrous oxide (N2O). The concentration of N2O was measured with a root mean squared error of 6 ppb. The results compared well with lab-based gas chromatography measurements. (C) 2013 Optical Society of America
引用
收藏
页码:B93 / B101
页数:9
相关论文
共 50 条
  • [1] A REFLECTANCE ANISOTROPY SPECTROMETER FOR REAL-TIME MEASUREMENTS
    ACHER, O
    DREVILLON, B
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (11): : 5332 - 5339
  • [2] IMPROVED CHAMBER SYSTEMS FOR RAPID, REAL-TIME NITROUS OXIDE EMISSIONS FROM MANURE AND SOIL
    Parker, D. B.
    Casey, K. D.
    Todd, R. W.
    Waldrip, H. M.
    Marek, G. W.
    Auvermann, B. W.
    Marek, T. H.
    Webb, K.
    Willis, W. M.
    Pemberton, B.
    Meyer, B.
    TRANSACTIONS OF THE ASABE, 2017, 60 (04) : 1235 - 1258
  • [3] Low-Cost Real-Time Localisation for Agricultural Robots in Unstructured Farm Environments
    Liu, Chongxiao
    Nguyen, Bao Kha
    MACHINES, 2024, 12 (09)
  • [4] A portable low-cost incubation chamber for real-time characterization of soil respiration
    Nguyen, Thi Thuc
    Altman, Ariel
    Huang, Laibin
    Rodrigues, Jorge L. Mazza
    Dahlke, Helen E.
    Kamennaya, Nina A.
    Levintal, Elad
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2025, 89 (01)
  • [5] A Study of FTIR Spectrometry Based on a Long Optical Path on the Emission Rules of Nitrous Oxide from Soil
    Xiao Guang-dong
    Zheng Ling
    Dong Da-ming
    Zhang Dong-yan
    Zhang Bao-hua
    Liao Tong-qing
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35 (11) : 3063 - 3067
  • [6] Wavelet analysis of the correlations between soil properties and potential nitrous oxide emission at farm and landscape scales
    Milne, A. E.
    Haskard, K. A.
    Webster, C. P.
    Truan, I. A.
    Goulding, K. W. T.
    Lark, R. M.
    EUROPEAN JOURNAL OF SOIL SCIENCE, 2011, 62 (03) : 467 - 478
  • [7] Real-Time FTIR Etch Depth Measurements in Passive Integrated Silicon Substrates
    Roullier, F.
    Domenges, B.
    Poirier, P.
    Blanvillain, J. P.
    ISTFA 2007, 2007, : 93 - +
  • [8] Evaluation of low-cost sensors to integrate in a water quality monitor for real-time measurements
    Slongo, Juliano
    Lindino, Cleber
    Martins, Leila D.
    Spanhol, Fabio A.
    Carneiro, Edipo
    Camargo, Edson T.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2024, 196 (08)
  • [9] Low Cost Dynamic Scrubbing for Real-Time Systems
    Santos, Leonardo P.
    Nazar, Gabriel L.
    Carro, Luigi
    APPLIED RECONFIGURABLE COMPUTING, ARC 2016, 2016, : 144 - 156
  • [10] A low cost real-time intelligent taximeter sensor
    Jantarang, S
    Potipantong, P
    Worapishet, A
    APCCAS 2002: ASIA-PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS, VOL 1, PROCEEDINGS, 2002, : 217 - 220