Measurement of mini-implant stability using resonance frequency analysis

被引:39
|
作者
Nienkemper, Manuel [1 ]
Wilmes, Benedict [1 ]
Panayotidis, Agamemnon [1 ]
Pauls, Alexander [1 ]
Golubovic, Vladimir [2 ]
Schwarz, Frank [2 ]
Drescher, Dieter [1 ]
机构
[1] Univ Dusseldorf, Dept Orthodont, D-40225 Dusseldorf, Germany
[2] Univ Dusseldorf, Dept Oral Surg & Admittance, D-40225 Dusseldorf, Germany
关键词
Orthodontics; Skeletal anchorage; Implant stability; Resonance frequency analysis; DAMPING CAPACITY ASSESSMENT; ORTHODONTIC ANCHORAGE; IN-VITRO; BONE THICKNESS; MICRO-IMPLANTS; INTERFACE; FAILURE; TISSUE;
D O I
10.2319/043012-354.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To investigate whether resonance frequency analysis (RFA) is suitable to measure orthodontic mini-implant stability. Implant size significantly affects the level of resonance frequency. Regarding the operating mode of RFA, it has to be proven whether the resonance frequency of mini-implants in bone fits the range of frequency emitted by the Osstell ISO device. Material and Methods: For this purpose the SmartPegs in the Osstell ISO device were modified to fit with the inner screw thread of orthodontic mini-implants, and 110 mini-implants were inserted into porcine pelvic bone. RFA was performed parallel and perpendicular to the run of superficial bone fibers. A suitability test, Periotest, was also performed in the same directions. Compacta thickness was measured using cone-beam computed tomography. Correlation tests and linear regression analysis were carried out between the three methods. Results: The RFA showed a mean Implant Stability Quotient value of 36.36 +/- 2.67, and the Periotest mean value was -2.10 +/- 1.17. The differences between the two directions of measurement were statistically significant (P > .001) for RFA and the Periotest. There was a high correlation between RFA and the Periotest (r = -0.90) and between RFA and compacta thickness (r = 0.71). The comparison between the Periotest and compacta thickness showed a correlation coefficient of r = -0.64. Conclusion: The present results suggest that RFA is feasible as a measurement method for orthodontic mini-implant stability. As a consequence, it could be used for clinical evaluation of current stability and allow stability-related loading of mini-implants to reduce the failure rate. (Angle Orthod. 2013;83:230-238.)
引用
收藏
页码:230 / 238
页数:9
相关论文
共 50 条
  • [31] Systematic review of mini-implant displacement under orthodontic loading
    Manuel Nienkemper
    Jörg Handschel
    Dieter Drescher
    International Journal of Oral Science, 2014, 6 : 1 - 6
  • [32] Effects of gripping volume in the mechanical strengths of orthodontic mini-implant
    Tseng, Yu-Chuan
    Wu, Ju-Hui
    Chen, Hong-Sen
    Chen, Chun-Ming
    Ting, Chun-Chan
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2017, 33 (11) : 578 - 583
  • [33] Biomechanical and histomorphometric properties of four different mini-implant surfaces
    Yadav, Sumit
    Upadhyay, Madhur
    Roberts, Wilbur Eugene
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (06) : 627 - 635
  • [34] Systematic review of mini-implant displacement under orthodontic loading
    Manuel Nienkemper
    Jrg Handschel
    Dieter Drescher
    International Journal of Oral Science, 2014, 6 (01) : 1 - 6
  • [35] Assessment of Implant Stability of Patients With and Without Radiotherapy Using Resonance Frequency Analysis
    Karayazgan-Saracoglu, Banu
    Atay, Arzu
    Zulfikar, Haluk
    Erpardo, Yuksel
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (01) : 30 - 35
  • [36] Prevalence and cause of mini-implant failure encountered by orthodontic residents
    Sreenivasagan S.
    Subramanian A.K.
    Rengalakshmi S.
    Journal of Long-Term Effects of Medical Implants, 2021, 31 (04) : 1 - 4
  • [37] An examination of immediately loaded dental implant stability in the diabetic patient using resonance frequency analysis (RFA)
    Balshi, Stephen F.
    Wolfinger, Glenn J.
    Balshi, Thomas J.
    QUINTESSENCE INTERNATIONAL, 2007, 38 (04): : 271 - 279
  • [38] Is It Possible to Monitor Implant Stability on a Prosthetic Abutment? An In Vitro Resonance Frequency Analysis
    Lopez-Jarana, Paula
    Maria Diaz-Castro, Carmen
    Falcao, Artur
    Rios-Carrasco, Blanca
    Fernandez-Palacin, Ana
    Rios-Santos, Jose-Vicente
    Herrero-Climent, Mariano
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (11) : 1 - 14
  • [39] Assessment of Miniscrew Implant Stability by Resonance Frequency Analysis: A Study in Human Cadavers
    Suzuki, Eduardo Yugo
    Suzuki, Boonsiva
    Aramrattana, Atchara
    Harnsiriwattanakit, Kanchana
    Kowanich, Narumanas
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (11) : 2682 - 2689
  • [40] Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration
    Vayron, Romain
    Vu-Hieu Nguyen
    Lecuelle, Benoit
    Lomami, Hugues Albini
    Meningaud, Jean-Paul
    Bosc, Romain
    Haiat, Guillaume
    SENSORS, 2018, 18 (05)