Manually-operated window shade patterns in office buildings: A critical review

被引:193
作者
O'Brien, William [1 ]
Kapsis, Konstantinos [2 ]
Athienitis, Andreas K. [2 ]
机构
[1] Carleton Univ, Dept Civil & Environm Engn, Ottawa, ON K1S 5B6, Canada
[2] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ H3G 1M8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Occupant behavior; Window shades; Thermal comfort; Visual comfort; Energy use; Advanced facade design; DISCOMFORT GLARE; THERMAL COMFORT; DAYLIGHTING PERFORMANCE; VENETIAN BLIND; SIMULATION; MODEL; IMPACT; BEHAVIOR; DEVICES; SYSTEMS;
D O I
10.1016/j.buildenv.2012.10.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Despite the significant impact that the position of movable shading devices has on building energy use, peak loads, and visual and thermal comfort, there is a high degree of uncertainty associated with how building occupants actually operate their shades. As a result, unrealistic modeling assumptions in building performance simulation or other design methods may lead to sub-optimal building designs and overestimation or underestimation of cooling loads. In the past 35 years, researchers have published observational studies in order to identify the factors that motivate building occupants to operate shading devices. However, the diversity of the study conditions makes it is difficult to draw universal conclusions that link all contributing factors to shade movement actions. This paper provides a comprehensive and critical review of experimental and study methodologies for manual shade operation in office buildings, their results, and their application to building design and controls. The majority of the many cited factors in office buildings can be categorized into those affecting visual comfort, thermal comfort, privacy, and views. Most office occupants do not operate their shades more than weekly or monthly and they do so based on long-term solar radiation intensity and solar geometry trends rather than reacting to short-term events. They generally operate them to improve visual conditions rather than thermal conditions. Occupants in offices with automatically-controlled heating and cooling tend to be less diligent about using shading devices to improve their comfort. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:319 / 338
页数:20
相关论文
共 80 条
[1]  
[Anonymous], 2006, SOLAR ENG THERMAL PR
[2]  
[Anonymous], 2005, HDB FUNDAMENTALS
[3]  
[Anonymous], DOE 2 BUILD EN US CO
[4]  
[Anonymous], 2010, WIND 6 3 SOFTW
[5]  
ANSI/ASHRAE/ IESNA, 2010, 9012010 ANSIASHRAEIE
[6]   Synthetically derived profiles for representing occupant-driven electric loads in Canadian housing [J].
Armstrong, Marianne M. ;
Swinton, Mike C. ;
Ribberink, Hajo ;
Beausoleil-Morrison, Ian ;
Millette, Jocelyn .
JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2009, 2 (01) :15-30
[7]  
Athienitis AK, 1992, STUDY EFFECTS SOLAR
[8]   Building-integrated PV modules [J].
Benemann, J ;
Chehab, O ;
Schaar-Gabriel, E .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2001, 67 (1-4) :345-354
[9]   Indoor thermal environmental conditions near glazed facades with shading devices - Part I: Experiments and building thermal model [J].
Bessoudo, M. ;
Tzempelikos, A. ;
Athienitis, A. K. ;
Zmeureanu, R. .
BUILDING AND ENVIRONMENT, 2010, 45 (11) :2506-2516
[10]   Adding advanced behavioural models in whole building energy simulation: A study on the total energy impact of manual and automated lighting control [J].
Bourgeois, D ;
Reinhart, C ;
Macdonald, I .
ENERGY AND BUILDINGS, 2006, 38 (07) :814-823