Improved quantification of mass fraction of colorants in textile by high-performance liquid chromatography coupled with tandem mass spectrometric detector

被引:3
作者
Tolgyesi, Adam [1 ]
Sharma, Virender K. [2 ]
Kulati, Anita [1 ]
机构
[1] EMI TUV SUD Ltd, Dugonics Utca 11, H-1043 Budapest, Hungary
[2] Texas A&M Univ, Program Environm & Sustainabil, Sch Publ Hlth, Dept Environm & Occupat Hlth, 212 Adriance Lab Rd,1266 TAMU, College Stn, TX 77843 USA
关键词
Colorants; Textiles; LC-MS; MS; HPLC-DAD; Standard method; Exact-matching double isotope dilution mass spectrometry; MILD EXTRACTION; DYES; IDENTIFICATION;
D O I
10.1007/s00769-020-01438-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The DIN 54231:2005 and ISO 16373-2:2014 standard methods recommend the application of HPLC separations and detection by either diode array (HPLC-DAD) or mass spectrometric detectors (LC-MS or LC-MS/MS) for the evaluation of mass concentration of colorants (y >= 1.0 mu g/mL) in textile sample extracts. The present investigation reports for the first time that the LC-MS/MS method has low accuracy for most of textile colorants if the recommended calibration range of the standard methods (1.0 mu g/mL to 20 mu g/mL or 5.0 mu g/mL to 50 mu g/mL) is used. The present paper reports that the quantification of mass concentration of colorants in textile extract by the LC-MS/MS method does not match with the quantification by the HPLC-DAD method, which has fit-for-purpose linearity and accuracy in the ranges mentioned above. A systematic study of the MS/MS method was performed to prepare real and spiked samples for quantifying mass concentration of colorants (y <= 1.0 mu g/mL) in textile extracts for compounds having LOQ <= 1.0 mg/kg. The results obtained could match with the quantification by the HPLC-DAD method. A lower calibration range was needed to quantify the dyes in the diluted sample extracts in which the background matrix constituents had lower influence on the quantification. Significantly, the LC-MS/MS method utilizing sample dilution and lower calibration range was validated and then used to proficiency test (PT) samples with success. Furthermore, the evaluation of mass fraction of disperse yellow 3 in PT sample by exact-matching double isotope dilution mass spectrometry was also performed. The strategy presented herein to quantify a wide range of colorants using the LC-MS/MS method could improve the reproducibility of analyzing colorants using protocols of standard recommendations.
引用
收藏
页码:259 / 272
页数:14
相关论文
共 33 条
  • [1] [Anonymous], JCGMWG1100
  • [2] [Anonymous], 2014, 1637322014 ISOFDIS
  • [3] [Anonymous], 2005, 54231200511 DIN
  • [4] Two-dimensional heart-cut LC-LC improves accuracy of exact-matching double isotope dilution mass spectrometry measurements of aflatoxin B1 in cereal-based baby food, maize, and maize-based feed
    Breidbach, Andreas
    Ulberth, Franz
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (11) : 3159 - 3167
  • [5] Towards the identification of the lichen species in historical orchil dyes by HPLC-MS/MS
    Cala, Elisa
    Benzi, Marcello
    Gosetti, Fabio
    Zanin, Andrea
    Gulmini, Monica
    Idone, Ambra
    Serafini, Ilaria
    Ciccola, Alessandro
    Curini, Roberta
    Whitworth, Isabella
    Aceto, Maurizio
    [J]. MICROCHEMICAL JOURNAL, 2019, 150
  • [6] Commission, 2014, OFF J EUR COMMUNIT L, V174, P45
  • [7] Council, 2002, OFF J EUR COMMUNIT L, V133, P29
  • [8] Council, 1999, OFF J EUR COMMUNIT L, V166, P87
  • [9] Direct Identification of Dyes in Textiles by Direct Analysis in Real Time-Time of Flight Mass Spectrometry
    DeRoo, Cathy Selvius
    Armitage, Ruth Ann
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (18) : 6924 - 6928
  • [10] Simultaneous identification of nine carcinogenic dyes from textiles by liquid chromatography/electrospray ionization mass spectrometry via negative/positive ion switching mode
    Ding, Youchao
    Sun, Cheng
    Xu, Xinhua
    [J]. EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2009, 15 (06) : 705 - 713