Freeze-drying in protective bags: Characterization of heat and mass transfer

被引:2
|
作者
Chamberlain, Rebecca [1 ,2 ]
Schlauersbach, Jonas [1 ,3 ]
Erber, Matthias [1 ]
机构
[1] Bayer AG, Friedrich Ebert Str 217-333, Wuppertal, Germany
[2] Heinrich Heine Univ Duesseldorf, Inst Pharmaceut & Biopharmaceut, D-40225 Dusseldorf, Germany
[3] Univ Wurzburg, Inst Pharm & Food Chem, D-97074 Wurzburg, Germany
关键词
Lyophilization; Freeze-drying; Drying; Heat transfer; Mass transfer; Sublimation tests; Highly potent APIs; PHARMACEUTICALS; TEMPERATURE; RESISTANCE; DESIGN; IMPACT;
D O I
10.1016/j.ejpb.2020.07.013
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
During lyophilisation of highly potent Active Pharmaceutical Ingredients (APIs) potential contamination of the freeze-drier is an important safety issue. Since the stoppers are in semistoppered position during the lyophilization process, API may contaminate the chamber and cross-contamination may occur as well. In this study two protective bags, which enclose each tray and their influence on heat and mass transfer during freeze-drying were investigated. Sublimation tests were performed using either purified water or solutions containing trehalose as well as hydroxypropyl-beta-cyclodextrin (HPbCD) as bulking agents. During sublimation tests with purified water both bags clearly influenced heat and mass transfer compared to unpacked reference vials. The bag, which was originally designed to be used for steam sterilization, had a massive impact on drying characteristics. The bag membrane becomes the rate limiting factor, generating a separate compartment within the bag. In this compartment vapor pressure is much higher compared to the chamber pressure during primary drying, leading to altered drying conditions. However, drying was still possible. The other bag, which was specifically designed for lyophilization, also had an impact on drying behavior which could be assigned to the foil between shelf and bottom of the vials. This was detectable as differences in K-v values. Membrane resistance, however, becomes negligible when 10% (w/w) trehalose or HPbCD solutions were dried using the later bag as containment. The data reported in this work demonstrate the relevance and value of sublimation tests to understand the lyophilization process, especially when new components are implemented. The data should be considered, when freeze-drying shall be performed using such bags.
引用
收藏
页码:309 / 316
页数:8
相关论文
共 50 条
  • [31] A comparative study of freeze-drying heat transfer in polymeric vials and glass vials
    Morteza Sarmadi
    Spencer Holmes
    Royal Agha
    Brandon Davenport
    Christopher Weikart
    T. N. Thompson
    Scientific Reports, 13
  • [32] Theoretical analysis of heat transfer of adsorption fluidization freeze-drying at atmospheric pressure
    Zhongguo Shiyou Daxue Xuebao (Ziran Kexue Ban), 2007, 4 (102-105+111):
  • [33] FREEZE-DRYING
    HEDLUND, P
    NORDISK MEDICIN, 1952, 48 (42) : 1455 - 1457
  • [34] A comparative study of freeze-drying heat transfer in polymeric vials and glass vials
    Sarmadi, Morteza
    Holmes, Spencer
    Agha, Royal
    Davenport, Brandon
    Weikart, Christopher
    Thompson, T. N.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [35] Experimental Aspects of Measuring the Vial Heat Transfer Coefficient in Pharmaceutical Freeze-Drying
    Wegiel, Lindsay A.
    Ferris, Steven J.
    Nail, Steven L.
    AAPS PHARMSCITECH, 2018, 19 (04): : 1810 - 1817
  • [36] Heat transfer characteristics of current primary packaging systems for pharmaceutical freeze-drying
    Hibler, Susanne
    Gieseler, Henning
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2012, 101 (11) : 4025 - 4031
  • [37] FREEZE-DRYING
    MCLACHLA.T
    CHEMISTRY & INDUSTRY, 1974, (07) : 308 - 308
  • [38] FREEZE-DRYING
    LONGMORE, AP
    CHEMISTRY & INDUSTRY, 1973, (20) : 970 - 974
  • [39] Experimental Aspects of Measuring the Vial Heat Transfer Coefficient in Pharmaceutical Freeze-Drying
    Lindsay A. Wegiel
    Steven J. Ferris
    Steven L. Nail
    AAPS PharmSciTech, 2018, 19 : 1810 - 1817
  • [40] Freeze-drying
    Aschkenasy, H
    SCIENTIFIC AMERICAN, 1996, 275 (03) : 184 - 184