Reliability-based optimisation design of post-tensioned concrete box girder bridges considering pitting corrosion attack

被引:13
|
作者
Van-Son Nguyen [1 ]
Jeong, Min Chul [1 ]
Han, Tong Seok [2 ]
Kong, Jung Sik [1 ]
机构
[1] Korea Univ, Sch Civil Environm & Architecture Engn, Anam Dong 13670, South Korea
[2] Yonsei Univ, Coll Engn, Sch Civil & Environm Engn, Seoul 120749, South Korea
关键词
reliability-based design optimisation; structural optimisation; pitting corrosion; structural reliability; prestressed concrete; STRUCTURAL RELIABILITY; MODEL; STRENGTH;
D O I
10.1080/15732479.2010.524653
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Since the mid-twentieth century, prestressed concrete (PC) bridges have been significantly developed to become the most important type of bridge in the world. However, only a few studies have dealt with the reliability-based design optimisation (RBDO) of PC bridges despite the fact that RBDO demonstrates the real behaviour of structures. Moreover, the corrosion of post-tensioned tendon in PC bridges seriously caused sudden failures which have been recorded in the world. Since then, this study presents the probabilistic model and approach to formulate and analyse the RBDO of PC box girder bridges which consider the pitting corrosion phenomenon of shear, torsion reinforcements and post-tensioned tendon. A practical example of a typical PC box girder bridge is presented and discussed. Sensitive analyses are performed to evaluate the influence of ultimate target reliability index on the optimal solution. For the simple support PC box girder bridge, the ultimate target reliability index should be in the range of beta(ult): 3.5-5 in order to produce the optimal design.
引用
收藏
页码:78 / 96
页数:19
相关论文
共 50 条
  • [1] Lifetime reliability-based optimization of post-tensioned box-girder bridges
    Garcia-Segura, Tatiana
    Yepes, Victor
    Frangopol, Dan M.
    Yang, David Y.
    ENGINEERING STRUCTURES, 2017, 145 : 381 - 391
  • [2] Time-Dependent Reliability Assessment and Updating of Post-tensioned Concrete Box Girder Bridges Considering Traffic Environment and Corrosion
    Kim, Jihwan
    Song, Junho
    ASCE-ASME JOURNAL OF RISK AND UNCERTAINTY IN ENGINEERING SYSTEMS PART A-CIVIL ENGINEERING, 2021, 7 (04)
  • [3] Assessment and strengthening of post-tensioned concrete box-girder bridges
    Stroscio R.
    Malik A.
    Turlier F.
    Structural Engineer, 2023, 101 (09): : 8 - 13
  • [4] THE CAUSE OF CRACKING IN POST-TENSIONED CONCRETE BOX GIRDER BRIDGES AND RETROFIT PROCEDURES
    PODOLNY, W
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1985, 30 (02): : 82 - 139
  • [5] Bridge deck analysis of transversely post-tensioned concrete box girder bridges
    Edmunds, James
    Franco, Luke
    Jayasinghe, Thushara
    Ginigaddara, Thusitha
    Vaz-Serra, Paulo
    Mendis, Priyan
    ELECTRONIC JOURNAL OF STRUCTURAL ENGINEERING, 2023, 23 (01): : 46 - 63
  • [6] Reliability-based inspection of post-tensioned concrete slabs
    Pandey, MD
    Nessim, MA
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1996, 23 (01) : 242 - 249
  • [7] Hybrid harmony search for sustainable design of post-tensioned concrete box-girder pedestrian bridges
    Garcia-Segura, Tatiana
    Yepes, Victor
    Alcala, Julian
    Perez-Lopez, Eloy
    ENGINEERING STRUCTURES, 2015, 92 : 112 - 122
  • [8] Reliability of post-tensioned concrete slab bridges
    Tabsh, SW
    PROBABILISTIC MECHANICS & STRUCTURAL RELIABILITY: PROCEEDINGS OF THE SEVENTH SPECIALTY CONFERENCE, 1996, : 712 - 715
  • [9] Crack-based serviceability assessment of post-tensioned segmental concrete box-girder bridges
    He, Zhi-Qi
    Li, Yonghui
    Xu, Tian
    Liu, Zhao
    Ma, Zhongguo John
    STRUCTURES, 2021, 30 : 1097 - 1108
  • [10] Crack Width Formula for Transversely Post-Tensioned Concrete Deck Slabs in Box Girder Bridges
    Choi, Young Cheol
    Oh, Byung Hwan
    ACI STRUCTURAL JOURNAL, 2009, 106 (06) : 753 - 761