Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation

被引:14
|
作者
Kim, Byeong-Keuk [1 ]
Shin, Dong-Ho [1 ]
Kim, Jung-Sun [1 ]
Ko, Young-Guk [1 ]
Choi, Donghoon [1 ]
Jang, Yangsoo [1 ,2 ]
Hong, Myeong-Ki [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Div Cardiol, Severance Cardiovasc Hosp, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2012年 / 28卷 / 08期
关键词
Optical coherence tomography; Coronary artery disease; Stent; INTRAVASCULAR ULTRASOUND; FOLLOW-UP; NEOINTIMAL COVERAGE; II TRIAL; APPOSITION; THROMBOSIS; LESIONS;
D O I
10.1007/s10554-012-0039-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Minimal data exist regarding the use of optical coherence tomography (OCT) to evaluate malapposed strut coverage following implantation of drug-eluting stents (DESs). Follow-up OCT examination after DES implantation was performed in 368 patients with 406 lesions at our institute. We assessed the status of malapposed strut coverage that was identified via OCT in 92 (23 %) lesions. An absence of uncovered struts among malapposed struts was defined as completely covered (CC) malapposition; the presence of uncovered struts was defined as incompletely covered (IC) malapposition. Among the 92 lesions with malapposed DES struts, CC malapposition was detected in 47 lesions (51 %). Compared to lesions with IC malapposition (n = 45, 49 %), lesions with CC malapposition showed a significantly lower percentage of uncovered struts among all the struts (14.9 +/- 14.5 vs. 4.4 +/- 8.5 %, respectively, p < 0.001) and among the other well-apposed struts without malapposition (12.7 +/- 12.8 vs. 4.5 +/- 8.7 %, respectively, p = 0.001). The degree of malapposed strut coverage was significantly different according to the type of DES; new-generation DESs such as everolimus- or zotarolimus-eluting stents showed a higher incidence of CC malapposition, compared to first-generation DESs such as sirolimus- or paclitaxel-eluting stents (82 vs. 34 %, respectively, p < 0.001). This study showed the complete coverage in about 50 % of the lesions with malapposed DES struts on follow-up OCT. The degree of malapposed DES strut coverage was strongly affected by the type of implanted DESs.
引用
收藏
页码:1887 / 1894
页数:8
相关论文
共 50 条
  • [41] Late Drug-Eluting Stent Thrombosis Optical Coherence Tomography and Intravascular Ultrasound Insights
    Alfonso, Fernando
    Gonzalo, Nieves
    Sandoval, Jorge
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (04) : 615 - 616
  • [42] Restenosis After Drug-Eluting Stent Implantation in a Patient With Polycythemia Vera Optical Coherence Tomography and Pathological Findings
    Fujino, Akiko
    Hao, Hiroyuki
    Kajimoto, Noriko
    Kawakami, Rika
    Imanaka, Takahiro
    Fujii, Kenichi
    Abe, Takashi
    Ishihara, Masaharu
    Hirota, Seiichi
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (07) : E111 - E112
  • [43] Optical coherence tomography derived cut-off value of uncovered stent struts to predict adverse clinical outcomes after drug-eluting stent implantation
    Won, Hoyoun
    Shin, Dong-Ho
    Kim, Byeong-Keuk
    Mintz, Gary S.
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06): : 1255 - 1263
  • [44] Predictors of strut coverage of drug eluting stent implantation in diabetic patients
    Briguori, Carlo
    Quintavalle, Cristina
    Donahue, Michael
    D'Alessio, Francesca
    D'Amore, Carmen
    Signoriello, Giuseppe
    del Vecchio, Luigi
    De Caterina, Raffaele
    Condorelli, Gerolama
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 276 : 61 - 65
  • [45] Serial Assessment of Strut Coverage of Biodegradable Polymer Drug-Eluting Stent at 1, 2, and 3 Months After Stent Implantation by Optical Frequency Domain Imaging The DISCOVERY 1TO3 Study (Evaluation With OFDI of Strut Coverage of Terumo New Drug Eluting Stent With Biodegradable Polymer at 1, 2, and 3 Months)
    Chevalier, Bernard
    Smits, Pieter C.
    Carrie, Didier
    Mehilli, Julinda
    Van Boven, Ad J.
    Regar, Evelyn
    Sawaya, Fadi J.
    Chamie, Daniel
    Kraaijeveld, Adriaan O.
    Hovasse, Thomas
    Vlachojannis, Georgios J.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (12)
  • [46] Morphologic characteristics of late stent malapposition after drug-eluting stents implantation by optical coherence tomography follow-up
    Hou Jing-bo
    Liu Hui-min
    Ma Li-jia
    Yang Shuang
    Meng Ling-bo
    Han Zhi-gang
    Zhang Shuo
    Yu Bo
    CHINESE MEDICAL JOURNAL, 2010, 123 (05) : 581 - 584
  • [47] Clinical impact of angiographically insignificant suboptimal poststent findings detected by optical coherence tomography after drug-eluting stent implantation
    Cho, Jae Young
    Kook, Hyungdon
    Yu, Cheol Woong
    PLOS ONE, 2020, 15 (10):
  • [48] Strut Coverage and Vessel Wall Response to a New-Generation Paclitaxel-Eluting Stent With an Ultrathin Biodegradable Abluminal Polymer Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI)
    Guagliumi, Giulio
    Sirbu, Vasile
    Musumeci, Giuseppe
    Bezerra, Hiram G.
    Aprile, Alessandro
    Kyono, Hiroyuki
    Fiocca, Luigi
    Matiashvili, Aleksandre
    Lortkipanidze, Nikoloz
    Vassileva, Angelina
    Popma, Jeffrey J.
    Allocco, Dominic J.
    Dawkins, Keith D.
    Valsecchi, Orazio
    Costa, Marco A.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (04) : 367 - U154
  • [49] Coronary plaque response after drug eluting stent implantation assessed by serial optical coherence tomography analysis
    Tian Feng
    Chen Yun-dai
    Chen Lian
    Sun Zhi-jun
    Liu Chang-fu
    Guo Jun
    Jin Qin-hua
    Wang Jin-da
    Gai Lu-yue
    CHINESE MEDICAL JOURNAL, 2011, 124 (22) : 3752 - 3756
  • [50] Correlation of angiographic late loss with neointimal coverage of drug-eluting stent struts on follow-up optical coherence tomography
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06): : 1289 - 1297