Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation

被引:14
作者
Kim, Byeong-Keuk [1 ]
Shin, Dong-Ho [1 ]
Kim, Jung-Sun [1 ]
Ko, Young-Guk [1 ]
Choi, Donghoon [1 ]
Jang, Yangsoo [1 ,2 ]
Hong, Myeong-Ki [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Div Cardiol, Severance Cardiovasc Hosp, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
关键词
Optical coherence tomography; Coronary artery disease; Stent; INTRAVASCULAR ULTRASOUND; FOLLOW-UP; NEOINTIMAL COVERAGE; II TRIAL; APPOSITION; THROMBOSIS; LESIONS;
D O I
10.1007/s10554-012-0039-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Minimal data exist regarding the use of optical coherence tomography (OCT) to evaluate malapposed strut coverage following implantation of drug-eluting stents (DESs). Follow-up OCT examination after DES implantation was performed in 368 patients with 406 lesions at our institute. We assessed the status of malapposed strut coverage that was identified via OCT in 92 (23 %) lesions. An absence of uncovered struts among malapposed struts was defined as completely covered (CC) malapposition; the presence of uncovered struts was defined as incompletely covered (IC) malapposition. Among the 92 lesions with malapposed DES struts, CC malapposition was detected in 47 lesions (51 %). Compared to lesions with IC malapposition (n = 45, 49 %), lesions with CC malapposition showed a significantly lower percentage of uncovered struts among all the struts (14.9 +/- 14.5 vs. 4.4 +/- 8.5 %, respectively, p < 0.001) and among the other well-apposed struts without malapposition (12.7 +/- 12.8 vs. 4.5 +/- 8.7 %, respectively, p = 0.001). The degree of malapposed strut coverage was significantly different according to the type of DES; new-generation DESs such as everolimus- or zotarolimus-eluting stents showed a higher incidence of CC malapposition, compared to first-generation DESs such as sirolimus- or paclitaxel-eluting stents (82 vs. 34 %, respectively, p < 0.001). This study showed the complete coverage in about 50 % of the lesions with malapposed DES struts on follow-up OCT. The degree of malapposed DES strut coverage was strongly affected by the type of implanted DESs.
引用
收藏
页码:1887 / 1894
页数:8
相关论文
共 23 条
[1]   Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage [J].
Barlis, Peter ;
Dimopoulos, Konstantinos ;
Tanigawa, Jun ;
Dzielicka, Ewa ;
Ferrante, Giuseppe ;
Del Furia, Francesca ;
Di Mario, Carlo .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 141 (02) :151-156
[2]   Coating irregularities of durable polymer-based drug-eluting stents as assessed by scanning electron microscopy [J].
Basalus, Mounir W. Z. ;
Ankone, Marc J. K. ;
van Houwelingen, K. Gert ;
de Man, Frits H. A. F. ;
von Birgelen, Clemens .
EUROINTERVENTION, 2009, 5 (01) :157-165
[3]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[4]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[5]   3-Year Clinical Follow-Up of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions The SPIRIT II Trial (Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions) [J].
Garg, Scot ;
Serruys, Patrick ;
Onuma, Yoshinobu ;
Dorange, Cecile ;
Veldhof, Susan ;
Miquel-Hebert, Karine ;
Sudhir, Krishnankutty ;
Boland, Jean ;
Huber, Kurt ;
Garcia, Eulogio ;
te Riele, Jan A. M. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (12) :1190-1198
[6]   Examination of the In Vivo Mechanisms of Late Drug-Eluting Stent Thrombosis Findings From Optical Coherence Tomography and Intravascular Ultrasound Imaging [J].
Guagliumi, Giulio ;
Sirbu, Vasile ;
Musumeci, Giuseppe ;
Gerber, Robert ;
Biondi-Zoccai, Giuseppe ;
Ikejima, Hideyuki ;
Ladich, Elena ;
Lortkipanidze, Nikoloz ;
Matiashvili, Aleksandre ;
Valsecchi, Orazio ;
Virmani, Renu ;
Stone, Gregg W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) :12-20
[7]   Delayed Coverage in Malapposed and Side-Branch Struts With Respect to Well-Apposed Struts in Drug-Eluting Stents In Vivo Assessment With Optical Coherence Tomography [J].
Gutierrez-Chico, Juan Luis ;
Regar, Evelyn ;
Nueesch, Eveline ;
Okamura, Takayuki ;
Wykrzykowska, Joanna ;
di Mario, Carlo ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Gobbens, Pierre ;
Jueni, Peter ;
Serruys, Patrick W. .
CIRCULATION, 2011, 124 (05) :612-U192
[8]   Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis [J].
Hassan, Ayman K. M. ;
Bergheanu, Sandrin C. ;
Stijnen, Theo ;
van der Hoeven, Bas L. ;
Snoep, Jaapjan D. ;
Plevier, Josepha W. M. ;
Schalij, Martin J. ;
Jukema, J. Wouter .
EUROPEAN HEART JOURNAL, 2010, 31 (10) :1172-1180
[9]   Late stent malapposition after drug-eluting stent implantation - An intravascular ultrasound analysis with long-term follow-up [J].
Hong, MK ;
Mintz, GS ;
Lee, CW ;
Park, DW ;
Park, KM ;
Lee, BK ;
Kim, YH ;
Song, JM ;
Han, KH ;
Kang, DH ;
Cheong, SS ;
Song, JK ;
Kim, JJ ;
Park, SW ;
Park, SJ .
CIRCULATION, 2006, 113 (03) :414-419
[10]   Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents [J].
Kim, J-S ;
Jang, I-K ;
Kim, J-S ;
Kim, T. H. ;
Takano, M. ;
Kume, T. ;
Hur, N. W. ;
Ko, Y-G ;
Choi, D. ;
Hong, M-K ;
Jang, Y. .
HEART, 2009, 95 (23) :1907-1912