Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation

被引:14
|
作者
Kim, Byeong-Keuk [1 ]
Shin, Dong-Ho [1 ]
Kim, Jung-Sun [1 ]
Ko, Young-Guk [1 ]
Choi, Donghoon [1 ]
Jang, Yangsoo [1 ,2 ]
Hong, Myeong-Ki [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Div Cardiol, Severance Cardiovasc Hosp, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
关键词
Optical coherence tomography; Coronary artery disease; Stent; INTRAVASCULAR ULTRASOUND; FOLLOW-UP; NEOINTIMAL COVERAGE; II TRIAL; APPOSITION; THROMBOSIS; LESIONS;
D O I
10.1007/s10554-012-0039-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Minimal data exist regarding the use of optical coherence tomography (OCT) to evaluate malapposed strut coverage following implantation of drug-eluting stents (DESs). Follow-up OCT examination after DES implantation was performed in 368 patients with 406 lesions at our institute. We assessed the status of malapposed strut coverage that was identified via OCT in 92 (23 %) lesions. An absence of uncovered struts among malapposed struts was defined as completely covered (CC) malapposition; the presence of uncovered struts was defined as incompletely covered (IC) malapposition. Among the 92 lesions with malapposed DES struts, CC malapposition was detected in 47 lesions (51 %). Compared to lesions with IC malapposition (n = 45, 49 %), lesions with CC malapposition showed a significantly lower percentage of uncovered struts among all the struts (14.9 +/- 14.5 vs. 4.4 +/- 8.5 %, respectively, p < 0.001) and among the other well-apposed struts without malapposition (12.7 +/- 12.8 vs. 4.5 +/- 8.7 %, respectively, p = 0.001). The degree of malapposed strut coverage was significantly different according to the type of DES; new-generation DESs such as everolimus- or zotarolimus-eluting stents showed a higher incidence of CC malapposition, compared to first-generation DESs such as sirolimus- or paclitaxel-eluting stents (82 vs. 34 %, respectively, p < 0.001). This study showed the complete coverage in about 50 % of the lesions with malapposed DES struts on follow-up OCT. The degree of malapposed DES strut coverage was strongly affected by the type of implanted DESs.
引用
收藏
页码:1887 / 1894
页数:8
相关论文
共 50 条
  • [1] Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation
    Byeong-Keuk Kim
    Dong-Ho Shin
    Jung-Sun Kim
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1887 - 1894
  • [2] Serial Optical Coherence Tomography-Based Observation of Strut Coverage on Drug-Eluting Stent Crossing Side-Branch Vessels
    Lee, Seung-Yul
    Kim, Jung-Sun
    Shin, Dong-Ho
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (11) : 569 - 573
  • [3] Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation
    Ko, Young-Guk
    Kim, Dong-Min
    Cho, Jin Man
    Choi, So Yeon
    Yoon, Jung Han
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04) : 715 - 723
  • [4] Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Oh, Changmyung
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04) : 705 - 714
  • [5] Impact of Statin Treatment on Strut Coverage after Drug-Eluting Stent Implantation
    Suh, Yongsung
    Kim, Byeong-Keuk
    Shin, Dong-Ho
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    YONSEI MEDICAL JOURNAL, 2015, 56 (01) : 45 - 52
  • [6] Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation
    Izumi, Daisuke
    Miyahara, Masatoshi
    Fujimoto, Naoki
    Fukuoka, Shusuke
    Sakai, Masataka
    Dohi, Kaoru
    Ito, Masaaki
    HEART AND VESSELS, 2016, 31 (08) : 1247 - 1256
  • [7] Relationship between endothelial vasomotor function and strut coverage after implantation of drug-eluting stent assessed by optical coherence tomography
    Won, Hoyoun
    Kim, Jung-Sun
    Shin, Dong-Ho
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (02) : 263 - 270
  • [8] Optical coherence tomography surveillance following drug-eluting stent implantation
    Koppara, T.
    Virmani, R.
    Joner, M.
    MINERVA CARDIOANGIOLOGICA, 2015, 63 (01): : 59 - 74
  • [9] Evaluation neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography
    Tian Feng
    Chen Yundai
    Liu Hongbin
    Chen Lian
    Sun Zhijun
    Guo Jun
    Jin Qinhua
    Zhang Tao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (08) : 1677 - 1683
  • [10] Evaluation of neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography
    Tian Feng
    Chen Yun-dai
    Chen Lian
    Sun Zhi-jun
    Guo Jun
    Jin Qin-hua
    Liu Chang-fu
    Wang Jin-da
    Liu Hong-bin
    CHINESE MEDICAL JOURNAL, 2013, 126 (11) : 2092 - 2097