No Evidence of Superiority in Reducing Outliers of Component Alignment for Patient-specific Instrumentation for Total Knee Arthroplasty: a Systematic Review

被引:22
作者
Zhang, Qing-meng [1 ]
Chen, Ji-ying [1 ]
Li, Heng [1 ]
Chai, Wei [1 ]
Ni, Ming [1 ]
Zhang, Zhen-dong [1 ]
Yang, Fan [1 ]
机构
[1] Peoples Liberat Army, Gen Hosp, Dept Orthopaed, Beijing 100853, Peoples R China
关键词
Component alignment; Radiograph; Total knee arthroplasty; CONVENTIONAL INSTRUMENTATION; COMPUTED-TOMOGRAPHY; CUTTING GUIDES; MATCHED INSTRUMENTATION; LIMB ALIGNMENT; TRIAL; TKA; METAANALYSIS; BLOCKS; CUSTOM;
D O I
10.1111/os.12150
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patient-specific instrumentation (PSI) technology has been developed to improve alignment when implanting total knee arthroplasty (TKA) and is a new focus in the orthopaedic community. Current controversial data concerning PSI are discussed. A systematic review to compare PSI with conventional instrumentation and assess the radiographic outcomes was performed. Electronic databases (including PubMed, Medline, Embase, the Cochrane Library and the Science Citation Index database) and conference proceedings from 1950 to 2014 in the English language were searched. Data, including relevant patient characteristics, sample size, radiographic method, PSI system manufacturer and outliers of implant positioning and alignment on radiography were independently extracted from all eligible studies by two of the authors. A total of 2739 TKAs were included (1410 performed with PSI and 1329 with conventional instrumentation). There were more TCA outliers (malalignment >3 degrees) and tibial slope outliers (malalignment >3 degrees) in the PSI group than in the conventional group. The other radiographic outcomes assessed, including coronal, sagittal or rotational alignment outliers did not differ between the two groups. With regard to radiographic outcomes, our findings indicate that PSI technology is not superior in reducing outliers of component alignment.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 41 条
[1]   Patient specific cutting blocks are currently of no proven value [J].
Barrack, R. L. ;
Ruh, E. L. ;
Williams, B. M. ;
Ford, A. D. ;
Foreman, K. ;
Nunley, R. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11) :95-99
[2]   Evaluating comorbidities in total hip and knee arthroplasty: available instruments. [J].
Bjorgul K. ;
Novicoff W.M. ;
Saleh K.J. .
Journal of Orthopaedics and Traumatology, 2010, 11 (4) :203-209
[3]   Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial [J].
Boonen, B. ;
Schotanus, M. G. M. ;
Kerens, B. ;
van der Weegen, W. ;
van Drumpt, R. A. M. ;
Kort, N. P. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) :2206-2212
[4]   Preliminary experience with the patient-specific templating total knee arthroplasty 40 cases compared with a matched control group [J].
Boonen, Bert ;
Schotanus, Martijn G. M. ;
Kort, Nanne P. .
ACTA ORTHOPAEDICA, 2012, 83 (04) :387-393
[5]   Patient Satisfaction after Total Knee Arthroplasty Who is Satisfied and Who is Not? [J].
Bourne, Robert B. ;
Chesworth, Bert M. ;
Davis, Aileen M. ;
Mahomed, Nizar N. ;
Charron, Kory D. J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) :57-63
[6]   A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement [J].
Chareancholvanich, K. ;
Narkbunnam, R. ;
Pornrattanamaneewong, C. .
BONE & JOINT JOURNAL, 2013, 95B (03) :354-359
[7]   Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? [J].
Cheng, Tao ;
Zhao, Song ;
Peng, Xiaochun ;
Zhang, Xianlong .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (07) :1307-1322
[8]   The accuracy of component alignment in custom cutting blocks compared with, conventional total knee arthroplasty instrumentation: Prospective control trial [J].
Chotanaphuti, Thanainit ;
Wangwittayakul, Visit ;
Khuangsirikul, Saradej ;
Foojareonyos, Trakul .
KNEE, 2014, 21 (01) :185-188
[9]   Frontal plane alignment after total knee arthroplasty using patient-specific instruments [J].
Daniilidis, Kiriakos ;
Tibesku, Carsten O. .
INTERNATIONAL ORTHOPAEDICS, 2013, 37 (01) :45-50
[10]   Kinematically Versus Mechanically Aligned Total Knee Arthroplasty [J].
Dossett, H. Gene ;
Swartz, George J. ;
Estrada, Nicolette A. ;
LeFevre, George W. ;
Kwasman, Bertram G. .
ORTHOPEDICS, 2012, 35 (02) :E160-E169