Ultra-high b-value diffusion-weighted MRI for the detection of prostate cancer with 3-T MRI

被引:77
作者
Ueno, Yoshiko [1 ]
Kitajima, Kazuhiro [1 ]
Sugimura, Kazuro [1 ]
Kawakami, Fumi [2 ]
Miyake, Hideaki [3 ]
Obara, Makoto [4 ]
Takahashi, Satoru [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Radiol, Kobe, Hyogo 6500017, Japan
[2] Kobe Univ, Grad Sch Med, Dept Pathol, Kobe, Hyogo 6500017, Japan
[3] Kobe Univ, Grad Sch Med, Dept Urol, Kobe, Hyogo 6500017, Japan
[4] MR Clin Sci Philips Elect Japan, Tokyo, Japan
关键词
prostate cancer; 3-T MRI; diffusion-weighted imaging (DWI); ultra-high b-value; b=2000 s; mm(2); ZONE; LOCALIZATION; COMBINATION; IMPACT;
D O I
10.1002/jmri.23953
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine, with histopathological findings of radical prostatectomy as reference, whether diffusionweighted imaging (DWI) using b = 2000 s/mm(2) for 3-T magnetic resonance imaging (MRI) is superior to the use of b = 1000 s/mm(2) for prostate cancer detection. Materials and Methods: This study evaluated 73 patients with biopsy-proven prostate cancer. All patients underwent preoperative 3-T MRI using T2-weighted imaging (T2WI) and DWI (b = 0, 1000, 2000 s/mm(2)). The following three sets of images were evaluated separately by two radiologists: protocol A (T2WI alone), protocol B (T2WI and DWI with b = 1000 s/mm(2)), and protocol C (T2WI and DWI with b = 2000 s/mm(2)). For estimation of diagnostic capability, area under the receiver operating characteristic (ROC) curve (AUC) was calculated. Results: A total of 341 cancer foci were found in the prostectomy specimens of 73 patients. Reader 1 rated AUCs of the three sets as; A 0.66, B 0.77, C 0.80. ROC analysis showed significant differences among the three protocols (A vs. B vs. C: P < 0.0001, A vs. B: P < 0.0001, B vs. C: P < 0.0001). Conclusion: The use of b = 2000 s/mm(2) for DWI with 3-T MRI is diagnostically superior to that of b = 1000 s/mm(2) for prostate cancer detection.
引用
收藏
页码:154 / 160
页数:7
相关论文
共 22 条
[1]   Transition zone prostate cancers: Features, detection, localization, and staging at endorectal MR imaging [J].
Akin, Oguz ;
Sala, Evis ;
Moskowitz, Chaya S. ;
Kuroiwa, Kentaro ;
Ishill, Nicole M. ;
Pucar, Darko ;
Scardino, Peter T. ;
Hricak, Hedvig .
RADIOLOGY, 2006, 239 (03) :784-792
[2]   Detection of Prostate Cancer With Magnetic Resonance Imaging: Optimization of T1-Weighted, T2-Weighted, Dynamic-Enhanced T1-Weighted, Diffusion-Weighted Imaging Apparent Diffusion Coefficient Mapping Sequences and MR Spectroscopy, Correlated With Biopsy and Histopathological Findings [J].
Aydin, Hasan ;
Kizilgoz, Volkan ;
Tatar, Idil Gunes ;
Damar, Cagri ;
Ugan, Ali Riza ;
Paker, Iram ;
Hekimoglu, Baki .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (01) :30-45
[3]   Anatomic site-specific positive margins in organ-confined prostate cancer and its impact on outcome after radical prostatectomy [J].
Blute, ML ;
Bostwick, DG ;
Bergstralh, EJ ;
Slezak, JM ;
Martin, SK ;
Amling, CL ;
Zincke, H .
UROLOGY, 1997, 50 (05) :733-739
[4]   Prostate cancer detection: Comparison of T2-weighted imaging, diffusion-weighted imaging, proton magnetic resonance spectroscopic imaging, and the three techniques combined [J].
Chen, M. ;
Dang, H. -D. ;
Wang, J. -Y. ;
Zhou, C. ;
Li, S. -Y. ;
Wang, W. -C. ;
Zhao, W. -F. ;
Yang, Z. -H. ;
Zhong, C. -Y. ;
Li, G. -Z. .
ACTA RADIOLOGICA, 2008, 49 (05) :602-610
[5]   Characterization of low-intensity lesions in the peripheral zone of prostate on pre-biopsy endorectal coil MR imaging [J].
Cruz, M ;
Tsuda, K ;
Narumi, Y ;
Kuroiwa, Y ;
Nose, T ;
Kojima, Y ;
Okuyama, A ;
Takahashi, S ;
Aozasa, K ;
Barentsz, JO ;
Nakamura, H .
EUROPEAN RADIOLOGY, 2002, 12 (02) :357-365
[6]   Combined T2-weighted and diffusion-weighted MRI for localization of prostate cancer [J].
Haider, Masoom A. ;
van der Kwast, Theodorus H. ;
Tanguay, Jeff ;
Evans, Andrew J. ;
Hashmi, Ali-Tahir ;
Lockwood, Gina ;
Trachtenberg, John .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (02) :323-328
[7]  
Hricak H, 2007, RADIOLOGY, V213, P481
[8]  
JANSSEN MJFM, 1993, NEPHROL DIAL TRANSPL, V8, P1228
[9]   Ultra-high-b-value diffusion-weighted MR imaging for the detection of prostate cancer: evaluation in 201 cases with histopathological correlation [J].
Katahira, Kazuhiro ;
Takahara, Taro ;
Kwee, Thomas C. ;
Oda, Seitaro ;
Suzuki, Yasuko ;
Morishita, Shoji ;
Kitani, Kosuke ;
Hamada, Yasuyuki ;
Kitaoka, Mitsuhiko ;
Yamashita, Yasuyuki .
EUROPEAN RADIOLOGY, 2011, 21 (01) :188-196
[10]   High-b-Value Diffusion-Weighted Imaging at 3 T to Detect Prostate Cancer: Comparisons Between b Values of 1,000 and 2,000 s/mm2 [J].
Kim, Chan Kyo ;
Park, Byung Kwan ;
Kim, Bohyun .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) :W33-W37