The gas holdup in a multiphase reciprocating plate column filled with carboxymethylcellulose solutions

被引:5
|
作者
Stamenkovic, IS
Stamenkovic, OS
Bankovic-Ilic, IB
Lazic, ML
Veljkovic, VB
Skala, DU
机构
[1] Univ Nis, Fac Technol, Leskovac 16000, Serbia Monteneg
[2] Univ Belgrade, Fac Technol & Met, Belgrade 11000, Serbia Monteneg
关键词
reciprocating plate column; gas holdup; multiphase systems; carboxymethylcelulose;
D O I
10.2298/JSC0512533S
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Gas holdup was investigated in a gas-liquid and gas-liquid-solid reciprocating plate column (RPC) under various operation conditions. Aqueous carboxy-methylcellulose (sodium salt, CIVIC) Solutions were used as the liquid phase, the solid phase was spheres placed into interplate spaces, and the gas plase was air. The gas holdup in the RPC was influenced by: the vibration intensity, i.e., the power consumption, the superficial gas velocity, the solids content and the rheological properties of the liquid phase. The gas holdup increased with increasing vibration intensity and superficial gas velocity in both the two- and three-phase system. With increasing concentration of the CMC PP 50 Solution (Newtonian fluid), the gas holdup decreased, because the coalescence of the bubbles was favored by the higher liquid viscosity. In the case of the CMC PP 200 Solutions (non-Newtonian liquids), the gas holchip depends on the combined influence of the rheological properties of the liquid phase, the vibration intensity and the superficial gas velocity. The gas holdup in the three-phase systems was greater than that in the two-phase ones under the same operating conditions. Increasing the solids content has little influence on the gas holdup. The gas holdup was correlated with the power consumption (either the time-averaged or total power consuption) and the superficial gas velocity.
引用
收藏
页码:1533 / 1544
页数:12
相关论文
共 50 条
  • [11] Axial dispersion in a reciprocating plate column
    Lounes, M
    Thibault, J
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1996, 74 (02): : 187 - 194
  • [12] Heat transfer in a reciprocating plate column
    Rao, NVR
    Baird, MHI
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2000, 78 (06): : 1056 - 1064
  • [13] Mass transfer in a reciprocating plate column
    Garnica, A. I. C.
    Duarte, M. M. L.
    Curbelo, F. D. S.
    AFINIDAD, 2005, 62 (520) : 579 - 583
  • [14] THE RECIPROCATING PLATE COLUMN - DEVELOPMENT AND APPLICATIONS
    LO, TC
    BAIRD, MHI
    RAO, NVR
    CHEMICAL ENGINEERING COMMUNICATIONS, 1992, 116 : 67 - 88
  • [15] Gas hold-up in a three-phase reciprocating plate column
    Nikolic, LB
    Nikolic, VD
    Veljkovic, VB
    Skala, DU
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2005, 70 (11) : 1363 - 1371
  • [16] HYDRODYNAMICS AND POWER-CONSUMPTION OF A RECIPROCATING PLATE GAS-LIQUID COLUMN
    LOUNES, M
    THIBAULT, J
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1993, 71 (04): : 497 - 506
  • [17] Oxygen mass transfer in a 16.6 cm i. d. multiphase reciprocating plate column
    Vasio, Ljubisa S.
    Bankovic-Ilic, Ivana B.
    Lazic, Miodrag L.
    Veljkovic, Vlada B.
    Skala, Dejan U.
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2007, 72 (05) : 523 - 531
  • [18] Effects of geometric properties of a perforated plate used as gas distributor on average gas holdup in a bubble column
    Kawasaki, Hiroyuki
    Kato, Hiroyuki
    Yamamoto, Tatsumi
    Kumazawa, Hidehiro
    KAGAKU KOGAKU RONBUNSHU, 2007, 33 (01) : 34 - 37
  • [19] OPERATIONAL CHARACTERISTICS OF A NOVEL RECIPROCATING PLATE MULTIPHASE CONTACTOR
    ALTAWEEL, AM
    LANDAU, J
    BOYLE, J
    GOMAA, HG
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1995, 73 (A6): : 707 - 712
  • [20] Single drop breakage in a reciprocating plate column
    Zhang, Jiyizhe
    Berry, Joseph D.
    Mumford, Kathryn A.
    Harvie, Dalton J. E.
    Fei, Weiyang
    Stevens, Geoffrey W.
    Wang, Yundong
    CHEMICAL ENGINEERING JOURNAL, 2021, 415