Fluoroscopy-guided versus CT-guided Lumbar Steroid Injections: Comparison of Radiation Exposure and Outcomes

被引:33
作者
Dietrich, Tobias J. [1 ,3 ]
Peterson, Cynthia K. [1 ,3 ]
Zeimpekis, Konstantinos G. [2 ,3 ]
Bensler, Susanne [1 ,3 ]
Sutter, Reto [1 ,3 ]
Pfirrmann, Christian W. A. [1 ,3 ]
机构
[1] Orthoped Univ Hosp Balgrist, Dept Radiol, Zurich, Switzerland
[2] Univ Hosp Zurich, Dept Nucl Med, Div Med Phys, Zurich, Switzerland
[3] Univ Zurich, Fac Med, Zurich, Switzerland
关键词
NERVE ROOT BLOCKS; CONVERSION FACTORS; MODIC CHANGES; PARTICULATE;
D O I
10.1148/radiol.2018181224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the radiation exposure for participants and interventionalists as well as participant outcomes between fluoroscopy-guided versus CT-guided lumbar spinal injections. Materials and Methods: This prospective, nonrandomized observational study included 1446 participants (mean age, 60.6 years; range, 18-91 years) who received transforaminal epidural injections or facet joint injections under fluoroscopic or CT guidance between October 2009 and April 2016. Effective doses were estimated by conversion from dose-area product for fluoroscopy-guided injections and dose-length product for CT-guided injections. Radiation exposure for interventionalists was measured with dosimeters at the body and wrist. The Patient Global Impression of Change (PGIC) scale was used to assess clinical participant outcomes at 1 day, 1 week, and 1 month after lumbar spine injections. Student t and chi(2) tests were used for statistical analysis. Results: The mean effective participant dose for fluoroscopy-guided lumbar transforaminal epidural injections was 0.24 mSv +/- 0.22, compared with 0.33 mSv +/- 0.10 for CT-guided injections (P < .003). The mean effective participant dose for fluoroscopy-guided lumbar facet joint injections was 0.10 mSv +/- 0.11, compared with 0.33 mSv +/- 0.13 for CT-guided injections (P < .001). Radiation exposure for the interventionalist was higher during fluoroscopy-guided compared with CT-guided lumbar transforaminal epidural injections (body: 0.42 x 10(-3) mSv +/- 0.99 vs 0.11 x 10(-3) mSv +/- 0.44, P < .03; wrist: 1.44 x 10(-3) mSv +/- 2.69 vs 0.14 x 10(-3) mSv +/- 0.55, P < .001). Radiation exposure of the wrist for the interventionalist was higher during fluoroscopy-guided compared with CT-guided lumbar facet injections (0.46 x 10(-3) mSv +/- 0.93 vs 0.06 x 10(-3) mSv +/- 0.24, respectively; P < .006). Clinical participant outcomes as determined with the PGIC scale did not differ between fluoroscopy-guided and CT-guided injections (P = .15-.96). Conclusion: Radiation exposure in fluoroscopy-guided lumbar spinal injections was lower for participants and higher for physicians when compared with CT-guided injections; however, no associations were observed between clinical participant outcomes and type of imaging-guided injection technique at all evaluated time points. (C) RSNA, 2018
引用
收藏
页码:752 / 759
页数:8
相关论文
共 30 条
  • [1] Particulate versus non-particulate corticosteroids for transforaminal nerve root blocks: Comparison of outcomes in 494 patients with lumbar radiculopathy
    Bensler, Susanne
    Sutter, Reto
    Pfirrmann, Christian W. A.
    Peterson, Cynthia K.
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (03) : 946 - 952
  • [2] Are the presence of MODIC changes on MRI scans related to "improvement" in low back pain patients treated with lumbar facet joint injections?
    Bianchi, Matilde
    Peterson, Cynthia K.
    Pfirrmann, Christian W. A.
    Hodler, Juerg
    Bolton, Jennifer
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [3] Use of active personal dosimeters in hospitals: EURADOS survey
    Ciraj-Bjelac, Olivera
    Carinou, Eleftheria
    Vanhavere, Filip
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 702 - 715
  • [4] Calculation of conversion factors for effective dose for various interventional radiology procedures
    Compagnone, Gaetano
    Giampalma, Emanuela
    Domenichelli, Sara
    Renzulli, Matteo
    Golfieri, Rita
    [J]. MEDICAL PHYSICS, 2012, 39 (05) : 2491 - 2498
  • [5] Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product
    Deak, Paul D.
    Smal, Yulia
    Kalender, Willi A.
    [J]. RADIOLOGY, 2010, 257 (01) : 158 - 166
  • [6] Particulate versus non-particulate steroids for lumbar transforaminal or interlaminar epidural steroid injections: an update
    Dietrich, Tobias J.
    Sutter, Reto
    Froehlich, Johannes M.
    Pfirrmann, Christian W. A.
    [J]. SKELETAL RADIOLOGY, 2015, 44 (02) : 149 - 155
  • [7] Capturing the patient's view of change as a clinical outcome measure
    Fischer, D
    Stewart, AL
    Bloch, DA
    Lorig, K
    Laurent, D
    Holman, H
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (12): : 1157 - 1162
  • [8] Risk of bleeding associated with interventional musculoskeletal radiology procedures. A comprehensive review of the literature
    Foremny, Gregory B.
    Pretell-Mazzini, Juan
    Jose, Jean
    Subhawong, Ty K.
    [J]. SKELETAL RADIOLOGY, 2015, 44 (05) : 619 - 627
  • [9] Fritz Jan, 2011, Top Magn Reson Imaging, V22, P143, DOI 10.1097/RMR.0b013e31827e5de1
  • [10] Interventional spine procedures under CT guidance: How to reduce patient radiation dose without compromising the successful outcome of the procedure?
    Greffier, Joel
    Pereira, Fabricio R.
    Viala, Pierre
    Macri, Francesco
    Beregi, Jean-Paul
    Larbi, Ahmed
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 35 : 88 - 96