LET dependence of the PTW-60019 microDiamond detector response in particle beams

被引:0
|
作者
Rossomme, S. [1 ]
Delor, A. [2 ]
Hopfgartner, J. [3 ]
Denis, J. [2 ]
Vynckier, S. [2 ]
Palmans, H. [4 ]
机构
[1] Catholic Univ Louvain, Inst Expt & Clin Res Mol Imaging Radiotherapy & O, Brussels, Belgium
[2] Clin Univ St Luc, Dept Radiotherapy & Oncol, Brussels, Belgium
[3] EBG MedAustron GmbH, Wiener Neustadt, Austria
[4] Natl Phys Lab, Acoust & Ionising Radiat Div Teddington, Teddington, Middx, England
关键词
D O I
10.1016/S0167-8140(16)32748-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
EP-1498
引用
收藏
页码:S692 / S692
页数:1
相关论文
共 22 条
  • [1] LET dependence of the response of a PTW-60019 microDiamond detector in a 62 MeV proton beam
    Rossomme, S.
    Denis, J. M.
    Souris, K.
    Delor, A.
    Bartier, F.
    Dumont, D.
    Vynckier, S.
    Palmans, H.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (09): : 1135 - 1138
  • [2] Under-response of a PTW-60019 microDiamond detector in the Bragg peak of a 62 MeV/n carbon ion beam
    Rossomme, S.
    Hopfgartner, J.
    Vynckier, S.
    Palmans, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (12): : 4551 - 4563
  • [3] A Monte Carlo study on the PTW 60019 microDiamond detector
    Hartmann, Guenther H.
    Zink, Klemens
    MEDICAL PHYSICS, 2019, 46 (11) : 5159 - 5172
  • [4] Dose rate dependence of the PTW 60019 microDiamond detector in high dose-per-pulse pulsed beams
    Brualla-Gonzalez, Luis
    Gomez, Faustino
    Pombar, Miguel
    Pardo-Montero, Juan
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01): : N11 - N19
  • [5] Properties of a commercial PTW-60019 synthetic diamond detector for the dosimetry of small radiotherapy beams
    Manuel Larraga-Gutierrez, Jose
    Ballesteros-Zebadua, Paola
    Rodriguez-Ponce, Miguel
    Amanda Garcia-Garduno, Olivia
    Galvan de la Cruz, Olga Olinca
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02): : 905 - 924
  • [6] Dose rate dependence of the PTW 60019 microDiamond detector in high dose-per-pulse pulsed beams
    Pardo-Montero, J.
    Brualla-Gonzalez, L.
    Gomez, F.
    Pombar, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S375 - S375
  • [7] Performance of a PTW 60019 microDiamond detector in a 1.5 T MRI-linac
    Woodings, S. J.
    Wolthaus, J. W. H.
    van Asselen, B.
    de Vries, J. H. W.
    Kok, J. G. M.
    Lagendijk, J. J. W.
    Raaymakers, B. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (05):
  • [8] Characterizing a PTW microDiamond detector in kilovoltage radiation beams
    Khan, Ahtesham Ullah
    Culberson, Wesley S.
    DeWerd, Larry A.
    MEDICAL PHYSICS, 2020, 47 (09) : 4553 - 4562
  • [9] Assessment of MicroDiamond PTW 60019 detector and its use in small radiosurgery fields of Leksell Gamma Knife
    Veselsky, T.
    Novotny, J., Jr.
    Pastykova, V.
    Pipek, J.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S108 - S108
  • [10] Response to "Comment on 'Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume' " [Med. Phys. 43, 6667 (2016)]
    Marinelli, Marco
    Prestopino, G.
    Verona, C.
    Verona-Rinati, G.
    MEDICAL PHYSICS, 2016, 43 (12) : 6668 - 6668