Does Rubidium-82 PET Have Superior Accuracy to SPECT Perfusion Imaging for the Diagnosis of Obstructive Coronary Disease? A Systematic Review and Meta-Analysis

被引:233
作者
Mc Ardle, Brian A. [1 ]
Dowsley, Taylor F. [1 ]
deKemp, Robert A. [1 ]
Wells, George A. [2 ]
Beanlands, Rob S. [1 ]
机构
[1] Univ Ottawa, Inst Heart, Natl Cardiac PET Ctr, Mol Funct & Imaging Program,Div Cardiol, Ottawa, ON K1Y 4W7, Canada
[2] Univ Ottawa, Inst Heart, Cardiac Res Methods Ctr, Ottawa, ON K1Y 4W7, Canada
关键词
accuracy; CAD; diagnosis; PET; SPECT; POSITRON-EMISSION-TOMOGRAPHY; TRANSIENT ISCHEMIC DILATION; ARTERY-DISEASE; ATTENUATION CORRECTION; COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; LEFT-VENTRICLE; GATED SPECT; STRESS; VALIDATION;
D O I
10.1016/j.jacc.2012.07.038
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The purpose of this study was to evaluate the accuracy of rubidium (Rb)-82 positron emission tomography (PET) for the diagnosis of obstructive coronary artery disease (CAD) in comparison to single-photon emission tomography (SPECT). Background Myocardial perfusion imaging is widely used in the assessment of patients with known or suspected CAD. PET using Rb-82 has potential advantages over SPECT that may make it more accurate and that reduce radiation exposure compared with SPECT but has increased costs. Comparisons of these technologies are highly relevant for policy makers and practice guidelines. However, studies directly comparing Rb-82 PET with contemporary SPECT have been limited. Method The authors therefore undertook a systematic review of studies where either Rb-82 PET or technetium-99m SPECT with both attenuation correction and electrocardiography-gating were used as a diagnostic test for obstructive CAD with invasive coronary angiogram as a reference standard. These technologies were then compared. Results Fifteen PET and 8 SPECT studies (1,344 and 1,755 patients, respectively) met inclusion criteria and pooled accuracy using weighted averages according to the size of the patient population was determined for PET and SPECT with sensitivities of 90% (confidence interval [CI]: 0.88 to 0.92) and 85% (CI: 0.82 to 0.87) and specificities of 88% (CI: 0.85 to 0.91) and 85% (CI: 0.82 to 0.87), respectively. Summary receiver-operating characteristic curves were computed: area under the curve was 0.95 and 0.90 for PET and SPECT, respectively (p < 0.0001). There was heterogeneity among study populations and some studies were limited by referral bias. Conclusions Rb-82 PET is accurate for the detection of obstructive CAD and, despite advances in SPECT technology, remains superior. More widespread use of Rb-82 PET may be beneficial to improve CAD detection. (J Am Coll Cardiol 2012;60:1828-37) (C) 2012 by the American College of Cardiology Foundation
引用
收藏
页码:1828 / 1837
页数:10
相关论文
共 43 条
  • [1] Multicenter investigation comparing a highly efficient half-time stress-only attenuation correction approach against standard rest-stress Tc-99m SPECT imaging
    Bateman, Timothy M.
    Heller, Gary V.
    McGhie, A. Iain
    Courter, Staci A.
    Golub, Robert A.
    Case, James A.
    Cullom, S. James
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (05) : 726 - 735
  • [2] Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT
    Bateman, TM
    Heller, GV
    McGhie, AI
    Friedman, JD
    Case, JA
    Bryngelson, JR
    Hertenstein, GK
    Moutray, KL
    Reid, K
    Cullom, SJ
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (01) : 24 - 33
  • [3] CCS/CAR/CANM/CNCS/CanSCMR joint position statement on advanced noninvasive cardiac imaging using positron emission tomography, magnetic resonance imaging and multidetector computed tomographic angiography in the diagnosis and evaluation of ischemic heart disease - executive summary
    Beanlands, R. S. B.
    Chow, B. J. W.
    Dick, A.
    Friedrich, M. G.
    Gulenchyn, K. Y.
    Kiess, M.
    Leong-Poi, H.
    Miller, R. M.
    Nichol, G.
    Freeman, M.
    Bogaty, P.
    Honos, G.
    Hudon, G.
    Wisenberg, G.
    Van Berkom, J.
    Williams, K.
    Yoshinaga, K.
    Graham, J.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (02) : 107 - 119
  • [4] Comparison of computed tomographic angiography versus rubidium-82 positron emission tomography for the detection of patients with anatomical coronary artery disease
    Chow, Benjamin J. W.
    Dennie, Carole
    Hoffmann, Udo
    So, Derek
    Dekemp, Robert A.
    Ruddy, Terrence D.
    Beanlands, Rob S.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (10) : 801 - 807
  • [5] ASSESSMENT OF CORONARY-ARTERY DISEASE SEVERITY BY POSITRON EMISSION TOMOGRAPHY - COMPARISON WITH QUANTITATIVE ARTERIOGRAPHY IN 193 PATIENTS
    DEMER, LL
    GOULD, KL
    GOLDSTEIN, RA
    KIRKEEIDE, RL
    MULLANI, NA
    SMALLING, RW
    NISHIKAWA, A
    MERHIGE, ME
    [J]. CIRCULATION, 1989, 79 (04) : 825 - 835
  • [6] Dorbala S, 2007, J NUCL MED, V48, P349
  • [7] Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT
    Esteves, Fabio P.
    Nye, Jonathan A.
    Khan, Akbar
    Folks, Russell D.
    Halkar, Raghuveer K.
    Garcia, Ernest V.
    Schuster, David M.
    Lerakis, Stamatios
    Raggi, Paolo
    Votaw, John R.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (02) : 247 - 253
  • [8] Adenosine stress rubidium-82 PET/computed tomography in patients with known and suspected coronary artery disease
    Esteves, Fabio R.
    Sanyal, Rupan
    Nye, Jonathon A.
    Santana, Cesar A.
    Verdes, Liudmila
    Raggi, Paolo
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (08) : 674 - 678
  • [9] Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography
    Fiechter, Michael
    Ghadri, Jelena R.
    Kuest, Silke M.
    Pazhenkottil, Aju P.
    Wolfrum, Mathias
    Nkoulou, Rene N.
    Goetti, Robert
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (11) : 2025 - 2030
  • [10] Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study
    Genovesi, Dario
    Giorgetti, Assuero
    Gimelli, Alessia
    Kusch, Annette
    Tagliavia, Irene D'Aragona
    Casagranda, Mirta
    Cannizzaro, Giorgio
    Giubbini, Raffaele
    Bertagna, Francesco
    Fagioli, Giorgio
    Rossi, Massimiliano
    Romeo, Annadina
    Bertolaccini, Pietro
    Bonini, Rita
    Marzullo, Paolo
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (10) : 1890 - 1898